UNLABELLED: A study was performed in a call center that provides billing inquiry services using a 2 x 2 balanced experimental plan for nine consecutive weeks. Two independent variables, temperature and outdoor air supply rate, were combined and introduced to the occupants in a blind intervention approach. The temperature set-points were fixed at 22.5 degrees C and 24.5 degrees C, and outdoor air supply rate at 5 l /s/p and 10 l/s/p. Temperature and outdoor air supply rate had significant interaction effects on worker's talk time (P < 0.001), which means that the effects of temperature on talk time performance were not independent of the effects of outdoor air supply rate or the opposite. Talk time was reduced significantly when the outdoor air supply rate was increased from 5 l /s/p to 10 l/s/p at 24.5 degrees C (P < 0.01); this may be associated with the significant reduction in a principal component factor which includes intensity of dryness, aching eyes and nose-related symptoms (P < 0.01). Decreasing the temperature from 24.5 degrees C to 22.5 degrees C at 10 l /s/p significantly increased talk time (P < 0.01). Analysis of the principal component factor based on the neurobehavioral symptoms also revealed that temperature reduction led to an increased mean factor score of these symptoms (P < 0.04). PRACTICAL IMPLICATIONS: For moderately complex office work which involves manipulation dexterity such as a call center operation where call operators interact with computer-based information systems, tropically acclimatized workers' performance could be improved by increasing the outdoor air supply rate from 5 l/s/p to 10 l/s/p if the temperature is to be maintained at the higher band of the thermal comfort range, around 24.5 degrees C. At a low ventilation rate (5 l/s/p), decreasing the temperature from 24.5 degrees C to 22.5 degrees C (which is a commonly adopted set-point in tropical office buildings) also leads to improvement of talk time performance. The magnitude of talk time improvement was greater by more than four times when the strategy to increase the outdoor air supply rate was implemented at a lower range of outdoor air supply rate (5-10 l /s/p) as compared to the higher range (9.8-22.7 l/s/p).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2004.00280.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 118

Metadata

Authors
Tham, K. W.
Venue
Indoor Air
Published
2004-08
Volume
14
Issue
s7
Pages
119-125
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2151252243
Cited by
118
References
1
FWCI
21.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Effects of temperature and outdoor air supply rate on the performance of call center operators in the tropics. https://app.cochat.ai/papers/10.1111/j.1600-0668.2004.00280.x
The paper
Tham, K. W. (2004). Effects of temperature and outdoor air supply rate on the performance of call center operators in the tropics. Indoor Air. https://doi.org/10.1111/j.1600-0668.2004.00280.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.