Ventilation and performance in office work

Open access
Seppanen, O., Fisk, W. J., Lei, Q. H.·2006·Indoor Air

Abstract

Previous work in the US (Persily and Gorfain, 2004) and Europe (Bluyssen et al., 1996) show large variation in measured ventilation rates between buildings and within buildings (Teijonsalo et al., 1996).In a significant fraction of buildings, particularly schools, the ventilation rates have been below guideline and standard values (Shendell et al., 2004).The outdoor air ventilation rates may be intentionally low because of design criteria or to save energy.Particularly in the US, air handling systems with no economizer and with a high percentage of recirculated return air in the supply air may provide low outdoor air flows.Some of the effects of ventilation rates have been long recognized.An increase of ventilation rate usually results in better perceived air quality and a lower concentration of indoor generated pollutants.Low ventilation rates generally lead to higher prevalences of adverse health effects, including SBS symptoms and air borne infectious diseases (Seppa¨nen et al., 1999).We have previously Abstract Outdoor air ventilation rates vary considerably between and within buildings, and may be too low in some spaces.The purpose of this study was to evaluate the potential work performance benefits of increased ventilation.We analyzed the literature relating work performance with ventilation rate and employed statistical analyses with weighting factors to combine the results of different studies.The studies included in the review assessed performance of various tasks in laboratory experiments and measured performance at work in real buildings.Almost all studies found increases in performance with higher ventilation rates.The studies indicated typically a 1-3% improvement in average performance per 10 l/s-person increase in outdoor air ventilation rate.The performance increase per unit increase in ventilation was bigger with ventilation rates below 20 l/s-person and almost negligible with ventilation rates over 45 l/sperson.The performance increase was statistically significant with increased ventilation rates up to 15 l/s-person with 95% CI and up to 17 l/s-person with 90% CI.

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2005.00394.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Health impacts of summer heat exposure are likely nonlinear, i.e., incremental increases in environmental heat load may lead to disproportionately higher risk.

    “Recognizing that health impacts of summer heat exposure are likely to be nonlinear48–51, i.e., incremental increases in environmental heat load may lead to disproportionately higher risk47”
  • Above a moderate threshold, damage is an increasing convex function of temperature.

    “Evidence suggests that above a moderate threshold damage is an increasing convex function of temperature, i.e., a 1° temperature increase causes more damage at higher temperatures48–51.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Seppanen, O., Fisk, W. J., & Lei, Q. H.
Affiliations
Lawrence Berkeley National Laboratory (US)
Venue
Indoor Air
Published
2006-02
Volume
16
Issue
1
Pages
28-36
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W1985083734
Cited by
303
References
1
Citations by year
2026: 12 · 2025: 11 · 2024: 12 · 2023: 15 · 2022: 16 · 2021: 17 · 2020: 18 · 2019: 22 · 2018: 17 · 2017: 20 · 2016: 16 · 2015: 16 · 2014: 23 · 2013: 20 · 2012: 12
FWCI
5.73
Type
journal article
Language
en
Open access
Locations
  • Indoor Air (publishedVersion)
  • PubMed (publishedVersion)
Funders
  • U.S. Department of Energy
  • U.S. Environmental Protection Agency
  • National Institute of Environmental Health Sciences (T32ES007142)
Topics
  • Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
  • Social Sciences › Psychology › Social Psychology › Facilities and Workplace Management
Keywords
ventilation rate, office work, employee performance, outdoor air ventilation, indoor air quality, sick building syndrome, indoor pollutants, return air, air handling systems
MeSH terms
Humans, Regression Analysis, Ventilation, Work, Air Pollution, Indoor

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review