The DOI matches its Crossref record.
Human response to personalized ventilation and mixing ventilation
Open accessAbstract
UNLABELLED: The response of 60 human subjects to a personalized ventilation system (PVS), providing control of positioning of the air terminal device and the airflow rate, was compared with the response to mixing ventilation (MV). Perceived air quality, thermal comfort, intensity of Sick Building Syndrome symptoms and performance of subjects were studied during 3 h 45 min exposures. In case of MV alone the room air temperature was 23 degrees C and 26 degrees C. The PVS supplied outdoor air at 23 degrees C or 20 degrees C or recirculated room air at 23 degrees C when the room temperature was 23 degrees C, and outdoor air at 20 degrees C when the room temperature was 26 degrees C. The PVS providing outdoor air improved perceived air quality and decreased SBS symptoms compared to MV alone and when the room air was re-circulated through the PVS. The percentage dissatisfied with air quality, 3 min after initial occupancy, decreased from 22% with MV to 7% with PVS; and from 49% to 20%, at room temperatures 23 degrees C and 26 degrees C, respectively. Over time, these differences in percentage dissatisfied decreased markedly. Headache and decreased ability to think clearly were reported as least intense when the PVS supplied outdoor air at 20 degrees C, while the most intense symptoms occurred with MV. PVS increased self-estimated performance. PRACTICAL IMPLICATIONS: Personalized ventilation can improve occupants' thermal comfort, perceived air quality and decrease the intensity of SBS symptoms compared to mixing ventilation. Occupants will use the provided individual control of airflow rate and positioning of the air terminal device to obtain preferred microenvironment in rooms where the air temperature is within the range recommended by indoor climate standards. Development of more efficient air terminal devices is recommended.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Phase change materials for smart textiles – An overview
Mondal, S. (2008) · Applied Thermal Engineering · doi:10.1016/j.applthermaleng.2007.08.009 · Cited by 1,171
A review of the performance of different ventilation and airflow distribution systems in buildings
Cao, G., Awbi, H., Yao, R., Fan, Y., Sirén, K., Kosonen, R., & Zhang, J. (. (2014) · Building and Environment · doi:10.1016/j.buildenv.2013.12.009 · Cited by 525
Wyon, D. P. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00278.x · Cited by 500
A review of the corrective power of personal comfort systems in non-neutral ambient environments
Zhang, H., Arens, E., & Zhai, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.03.013 · Cited by 411
Personalized conditioning and its impact on thermal comfort and energy performance – A review
Veselý, M., & Zeiler, W. (2014) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.03.024 · Cited by 322
Metadata
- Authors
- Kaczmarczyk, J., Melikov, A., & Fanger, P. O.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2004-12
- Volume
- 14
- Issue
- s8
- Pages
- 17-29
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2165545102
- Cited by
- 212
- References
- 0
- FWCI
- 21.31
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Human response to personalized ventilation and mixing ventilation. https://app.cochat.ai/papers/10.1111/j.1600-0668.2004.00300.x
- The paper
- Kaczmarczyk, J., Melikov, A., & Fanger, P. O. (2004). Human response to personalized ventilation and mixing ventilation. Indoor Air. https://doi.org/10.1111/j.1600-0668.2004.00300.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.