Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 500

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

The effects of indoor air quality on performance and productivity: The effects of IAQ on performance and productivity

Wyon, D. P.·2004·Indoor Air

Abstract

UNLABELLED: The main justification for ventilation has historically been to create a healthy indoor environment. Ventilation removes air pollutants originating inside the building, including bio-effluents. The outdoor air supply rate that has been found by experience to provide subjectively acceptable indoor air quality and to prevent the accumulation of moisture in the building is generally sufficient to maintain the concentration of pollutants at healthily low levels. Until 5 years ago this would have been the justification for current ventilation practices, but in 1999 the first of a series of experiments was published, revealing new mechanisms by which raised levels of indoor air pollution may reduce productivity, either in addition to or instead of having negative effects on comfort and health. It was shown in realistic experimental exposures lasting up to 5 h that the performance of simulated office work could be significantly increased by removing common indoor sources of air pollution, such as floor-coverings, used supply air filters and personal computers, or by keeping them in place and increasing the rate at which clean outdoor air was supplied from 3 to 10 to 30 l s(-1) per person. These short-term effects were demonstrated repeatedly even at pollutant levels that had no measurable effects on the perception of air quality by the occupants themselves, although there were effects on subclinical SBS symptoms such as headache. Temperature and noise distraction have since been studied in directly comparable exposures. The prediction arising from these experiments, that the performance of real office work over time would be significantly and substantially affected by the changes in indoor environmental quality that take place in the course of normal building operation, have recently been validated in 8-week field intervention experiments carried out in call-centers in northern Europe and the Tropics. These findings have far-reaching implications for the efficient use of energy in buildings. PRACTICAL IMPLICATIONS: It has now been shown beyond reasonable doubt that poor indoor air quality in buildings can decrease productivity in addition to causing visitors to express dissatisfaction. The size of the effect on most aspects of office work performance appears to be as high as 6-9%, the higher value being obtained in field validation studies. It is usually more energy-efficient to eliminate sources of pollution than to increase outdoor air supply rates. The experiments summarized in this article have documented and quantified relationships that can be used in making cost-benefit analyses of either solution for a given building. The high cost of labor per unit floor area ensures that payback times will usually be as low as 2 years.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2004.00278.x

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 500

Metadata

Authors
Wyon, D. P.
Venue
Indoor Air
Publisher
Wiley
Published
2004-08
Volume
14
Pages
92-101
ISSN
0905-6947 (ISSN-L)
OpenAlex
W2122919922
Cited by
500
References
13
FWCI
4.52
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The effects of indoor air quality on performance and productivity: The effects of IAQ on performance and productivity. https://app.cochat.ai/papers/10.1111/j.1600-0668.2004.00278.x
The paper
Wyon, D. P. (2004). The effects of indoor air quality on performance and productivity: The effects of IAQ on performance and productivity. Indoor Air. https://doi.org/10.1111/j.1600-0668.2004.00278.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.