CoChat

Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study

Open access
Tsai, F. C., Macher, J. M. · 2005 · Indoor Air
Cited by 113

The DOI matches its Crossref record.

Abstract

UNLABELLED: This paper presents summary statistics of airborne culturable bacteria from the US Environmental Protection Agency Building Assessment Survey and Evaluation (BASE) study. Air samples were collected with single-stage, multiple-hole, agar impactors in 100 large office buildings in 1994-1998 to obtain normative data on indoor environmental quality. Bacterial concentrations were compared by incubation temperature, location, season, and climate zone. Forty-one percent of the samples were below the 2- or 5-min detection limits (18 or 7 CFU/m3, respectively) but less than 1% were overgrown. Mesophilic bacteria (30 degrees C) accounted for >95% of culturable bacteria, both indoors and outdoors. Average concentrations were higher outdoors, except for Gram-positive cocci, which were the only group that were significantly higher indoors (39 vs. 24 CFU/m3), and Gram-negative cocci, for which both concentrations were low and the difference were not significant. Outdoor concentrations of culturable bacteria were somewhat higher in winter (194 vs.165 CFU/m3), and the two dominant outdoor groups were unknown bacteria and Gram-positive rods. Conversely, indoor concentrations were significantly higher in summer (116 vs. 87 CFU/m3), consisting primarily of unknown bacteria and Gram-positive cocci. Bacterial concentrations were within the ranges reported in previous studies of non-problem buildings, and the extreme aggregated indoor concentrations (e.g. the 90th percentile, 175 CFU/m3) of these 100 representative buildings may serve as upper bounds to develop interpretation guidelines for office environments and similar non-manufacturing workplaces in various climate zones. PRACTICAL IMPLICATIONS: The Building Assessment Survey and Evaluation (BASE) study was one of the most comprehensive investigations of indoor environmental quality in which a standardized protocol was used to measure bioaerosols in 100 typical US office buildings. The information on the indoor and outdoor concentrations of airborne bacteria in different climate zones during the heating and cooling seasons has expanded the baseline data available for interpretation of measurements from building investigations. With suggested refinements, the BASE protocol may serve as a guide for future studies of bioaerosol concentrations, building characteristics, and occupant perceptions of the indoor environment.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2005.00346.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 113

Metadata

Authors
Tsai, F. C., & Macher, J. M.
Venue
Indoor Air
Published
2005-06
Volume
15
Issue
s9
Pages
71-81
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2008499264
Cited by
113
References
0
FWCI
2.12
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study. https://app.cochat.ai/papers/10.1111/j.1600-0668.2005.00346.x
The paper
Tsai, F. C., & Macher, J. M. (2005). Concentrations of airborne culturable bacteria in 100 large US office buildings from the BASE study. Indoor Air. https://doi.org/10.1111/j.1600-0668.2005.00346.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.