CoChat

Mouse and cockroach allergens in the dust and air in northeastern United States inner-city public high schools

Chew, G. L., Correa, J. C., Perzanowski, M. S. · 2005 · Indoor Air
Cited by 78

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Considering that high school students spend a large proportion of their waking hours in the school environment, this could be an important location for exposure to indoor allergens. We have investigated the levels of mouse and cockroach allergens in the settled dust and air from 11 schools in a major northeastern US city. Settled dust samples were vacuumed from 87 classrooms, three times throughout the school year. Two separate air samples (flow = 2.5 lpm) were collected by 53 students over a 5-day period from both their school and their home. Mouse allergen (MUP) in the dust varied greatly between schools with geometric means ranging from 0.21 to 133 microg/g. Mouse allergen was detectable in 81% of the samples collected. Cockroach allergen (Bla g 2) ranged from below limit of detection (<0.003 microg/g) to 1.1 microg/g. Cockroach allergen was detected (>0.003 microg/g) in 71% of the dust samples. Bla g 2 was detected in 22% of airborne samples from the schools. By comparison, mouse allergen was only detected in 5%. These results indicate that the school may be an important location for exposure to allergens from mice and cockroaches and is an indoor environment that should be considered in an overall allergen intervention strategy. PRACTICAL IMPLICATIONS: To date, cockroach and mouse allergen intervention strategies have been mainly focused on the home environment. Considering that children spend a significant amount of time in schools, some studies have assessed cockroach allergen levels in schools. This study provides a clearer picture of the distribution and variability of not only cockroach allergen, but also mouse allergen in the school environment. In addition, this study describes limitations of personal air sampling in a student population. Our results suggest that although cockroach and mouse allergens are commonly recovered in classroom dust samples of inner city schools, cockroach allergens are recovered in the personal air samples with a greater frequency relative to mouse allergens.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0668.2005.00363.x

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 78

Metadata

Authors
Chew, G. L., Correa, J. C., & Perzanowski, M. S.
Venue
Indoor Air
Published
2005-08
Volume
15
Issue
4
Pages
228-234
ISSN
  • 0905-6947 (ISSN-L)
  • 1600-0668
OpenAlex
W2113923577
Cited by
78
References
6
FWCI
2.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mouse and cockroach allergens in the dust and air in northeastern United States inner-city public high schools. https://app.cochat.ai/papers/10.1111/j.1600-0668.2005.00363.x
The paper
Chew, G. L., Correa, J. C., & Perzanowski, M. S. (2005). Mouse and cockroach allergens in the dust and air in northeastern United States inner-city public high schools. Indoor Air. https://doi.org/10.1111/j.1600-0668.2005.00363.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.