Association between ventilation rates in 390 Swedish homes and allergic symptoms in children
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
UNLABELLED: The aim of the study was to test the hypothesis that a low-ventilation rate in homes is associated with an increased prevalence of asthma and allergic symptoms among children. A total of 198 cases (with at least two of three symptoms: wheezing, rhinitis, eczema) and 202 healthy controls, living in 390 homes, were examined by physicians. Ventilation rates were measured by a passive tracer gas method, and inspections were carried out in the homes. About 60% of the multi-family houses and about 80% of the single-family houses did not fulfill the minimum requirement regarding ventilation rate in the Swedish building code (0.5 air changes per hour, ach). Cases had significantly lower ventilation rates than controls and a dose-response relationship was indicated. PRACTICAL IMPLICATIONS: A low-ventilation rate of homes may be a risk factor for allergies among children. Families with allergic children should be given the advice to have good ventilation in the home. In investigations, of associations between environmental factors and allergies, the air change rate in homes has to be considered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bornehag, C.-G., Sundell, J., Weschler, C. J., Sigsgaard, T., Lundgren, B., Hasselgren, M., & Hägerhed-Engman, L. (2004) · Environmental Health Perspectives · doi:10.1289/ehp.7187 · Cited by 851
Self-citationWargocki, P., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418
Self-citationRelationship of indoor allergen exposure to skin test sensitivity in inner-city children with asthma
Eggleston, P. A., Rosenstreich, D., Lynn, H., Gergen, P., Baker, D., Kattan, M., Mortimer, K. M., Mitchell, H., Ownby, D., Slavin, R., et al. (1998) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(98)70272-6 · Cited by 331
Seppänen, O., & Fisk, W. J. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01111.x · Cited by 277
Proceedings of Healthy Buildings
Brohus, H. (2006) · Cited by 249
Bornehag, C.-G., Sundell, J., & Sigsgaard, T. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00274.x · Cited by 245
Self-citationSporik, R., Squillace, S. P., Ingram, J. M., Rakes, G., Honsinger, R. W., & Platts-Mills, T. A. E. (1999) · Thorax · doi:10.1136/thx.54.8.675 · Cited by 224
Ventilation in Homes and Bronchial Obstruction in Young Children
oie, L., Nafstad, P., Botten, G., Magnus, P., & Jaakkola, J. J. K. (1999) · Epidemiology · doi:10.1097/00001648-199905000-00018 · Cited by 188
WESCHLER, C. J., & SHIELDS, H. C. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010002092.x · Cited by 150
Emenius, G., Svartengren, M., Korsgaard, J., Nordvall, L., Pershagen, G., & Wickman, M. (2004) · Indoor Air · doi:10.1046/j.1600-0668.2003.00207.x · Cited by 114
Warner, J. A., Frederick, J. M., Bryant, T. N., Weich, C., Raw, G. J., Hunter, C., Stephend, F. R., McIntyre, D. A., & Warner, J. O. (2000) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(00)90181-7 · Cited by 108
Ventilation in homes infested by house‐dust mites
Sundell, J., Wickman, M., Pershagen, G., & Nordvall, S. L. (1995) · Allergy · doi:10.1111/j.1398-9995.1995.tb05065.x · Cited by 83
Self-citationHarving, H., Korsgaard, J., & Dahl, R. (1994) · Allergy · doi:10.1111/j.1398-9995.1994.tb00789.x · Cited by 82
Mite fauna in the home and sensitivity to house‐dust and storage mites
Warner, A., Boström, S., Moller, C. G., Kjellman, N., & Warner, A. (1999) · Allergy · doi:10.1034/j.1398-9995.1999.00850.x · Cited by 74
Measuring ventilation rates in the Swedish housing stock
Stymne, H., Boman, C. A., & Kronvall, J. (1994) · Building and Environment · doi:10.1016/0360-1323(94)90037-x · Cited by 46
Emenius, Egmar, A., & Wickman (1998) · Clinical & Experimental Allergy · doi:10.1046/j.1365-2222.1998.00408.x · Cited by 28
Ricci, PATRIZI, SPECCHIA, MENNA, BOTTAU, D’Angelo, & Masi (1999) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1999.02764.x · Cited by 23
Cited by
Allen, J. G., MacNaughton, P., Satish, U., Santanam, S., Vallarino, J., & Spengler, J. D. (2016) · Environmental Health Perspectives · doi:10.1289/ehp.1510037 · Cited by 977
Ventilation rates and health: Multidisciplinary review of the scientific literature
Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., et al. (2011) · Indoor Air · doi:10.1111/j.1600-0668.2010.00703.x · Cited by 740
“Although limited in scope, reviewed articles revealed poor ventilation conditions to be common in schools and homes, in relation to requirements in guidelines and standards (Bornehag et al., 2005; Smedje and Norbäck, 2000).”
BackgroundSelf-citationChanges in indoor pollutants since the 1950s
Weschler, C. J. (2009) · Atmospheric Environment · doi:10.1016/j.atmosenv.2008.09.044 · Cited by 669
Mendell, M. J. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00478.x · Cited by 437
Phthalates in Indoor Dust and Their Association with Building Characteristics
Bornehag, C.-G., Lundgren, B., Weschler, C. J., Sigsgaard, T., Hagerhed-Engman, L., & Sundell, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7809 · Cited by 433
Self-citation
Metadata
- Authors
- Bornehag, C. G., Sundell, J., Hagerhed-Engman, L., & Sigsgaard, T.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2005-08
- Volume
- 15
- Issue
- 4
- Pages
- 275-280
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W1984285505
- Cited by
- 199
- References
- 17
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.