Ventilation rates and health: Multidisciplinary review of the scientific literature
Open accessAbstract
UNLABELLED: The scientific literature through 2005 on the effects of ventilation rates on health in indoor environments has been reviewed by a multidisciplinary group. The group judged 27 papers published in peer-reviewed scientific journals as providing sufficient information on both ventilation rates and health effects to inform the relationship. Consistency was found across multiple investigations and different epidemiologic designs for different populations. Multiple health endpoints show similar relationships with ventilation rate. There is biological plausibility for an association of health outcomes with ventilation rates, although the literature does not provide clear evidence on particular agent(s) for the effects. Higher ventilation rates in offices, up to about 25 l/s per person, are associated with reduced prevalence of sick building syndrome (SBS) symptoms. The limited available data suggest that inflammation, respiratory infections, asthma symptoms and short-term sick leave increase with lower ventilation rates. Home ventilation rates above 0.5 air changes per hour (h(-1)) have been associated with a reduced risk of allergic manifestations among children in a Nordic climate. The need remains for more studies of the relationship between ventilation rates and health, especially in diverse climates, in locations with polluted outdoor air and in buildings other than offices. PRACTICAL IMPLICATIONS: Ventilation with outdoor air plays an important role influencing human exposures to indoor pollutants. This review and assessment indicates that increasing ventilation rates above currently adopted standards and guidelines should result in reduced prevalence of negative health outcomes. Building operators and designers should avoid low ventilation rates unless alternative effective measures, such as source control or air cleaning, are employed to limit indoor pollutant levels.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Health Effects of Fine Particulate Air Pollution: Lines that Connect
Pope, C. A., & Dockery, D. W. (2006) · Journal of the Air & Waste Management Association · doi:10.1080/10473289.2006.10464485 · Cited by 6,678 · see citing works
Fine Particulate Air Pollution and Hospital Admission for Cardiovascular and Respiratory Diseases
Dominici, F., Peng, R. D., Bell, M. L., Pham, L. D., McDermott, A., Zeger, S. L., & Samet, J. M. (2006) · JAMA · doi:10.1001/jama.295.10.1127 · Cited by 2,640 · see citing works
Self-citationVentilation for Acceptable Indoor Air Quality
Falih, M. (2019) · Cited by 1,995 · see citing works
Seppanen, O. A., Fisk, W. J., & Mendell, M. J. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.00003.x · Cited by 876 · see citing works
Self-citationWargocki, P. L., Wyon, D. P., Sundell, J., Clausen, G., & Fanger, P. O. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004222.x · Cited by 693 · see citing works
Self-citationEstimates of Improved Productivity and Health from Better Indoor Environments
Fisk, W. J., & Rosenfeld, A. H. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00002.x · Cited by 551 · see citing works
Self-citationWargocki, P. L., Wyon, D. P., Baik, Y. K., Clausen, G., & Fanger, P. O. (1999) · Indoor Air · doi:10.1111/j.1600-0668.1999.t01-1-00003.x · Cited by 509 · see citing works
Weschler, C. J. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9256 · Cited by 481 · see citing works
Self-citationBell, M. L., Peng, R. D., & Dominici, F. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.8816 · Cited by 481 · see citing works
Associations between classroom CO2 concentrations and student attendance in Washington and Idaho
Shendell, D. G., Prill, R., Fisk, W. J., Apte, M. G., Blake, D., & Faulkner, D. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00251.x · Cited by 462 · see citing works
Self-citationWargocki, P. L., Sundell, J., Bischof, W., Brundrett, G., Fanger, P. O., Gyntelberg, F., Hanssen, S. O., Harrison, P., Pickering, A., Seppänen, O., et al. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01145.x · Cited by 418 · see citing works
Self-citationRisk of Sick Leave Associated with Outdoor Air Supply Rate, Humidification, and Occupant Complaints
Milton, D. K., Glencross, P. M., & WALTERS, M. D. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004212.x · Cited by 364 · see citing works
Apte, M. G., Fisk, W. J., & Daisey, J. M. (2000) · Indoor Air · doi:10.1034/j.1600-0668.2000.010004246.x · Cited by 341 · see citing works
Self-citationAsthmatic symptoms and volatile organic compounds, formaldehyde, and carbon dioxide in dwellings.
Norbäck, D., Bjornsson, E. H., Janson, C., Widström, J., & Boman, G. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.6.388 · Cited by 331 · see citing works
Non-Specific Symptoms In Office Workers: A Review And Summary Of The Epidemiologic Literature
Mendell, M. J. (1993) · Indoor Air · doi:10.1111/j.1600-0668.1993.00003.x · Cited by 282 · see citing works
Association of ventilation system type with SBS symptoms in office workers
Seppänen, O., & Fisk, W. J. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01111.x · Cited by 277 · see citing works
Self-citationAn Epidemic of Pneumococcal Disease in an Overcrowded, Inadequately Ventilated Jail
Hoge, C. W., Reichler, M. R., Dominguez, E. A., Bremer, J. C., Mastro, T. D., Hendricks, K. A., Musher, D. M., Elliott, J. A., Facklam, R. R., & Breiman, R. F. (1994) · New England Journal of Medicine · doi:10.1056/nejm199409083311004 · Cited by 271 · see citing works
Mendell, M. J., Fisk, W. J., Kreiss, K., Levin, H., Alexander, D. L., Cain, W. S., Girman, J. R., Hines, C. J., Jensen, P. A., Milton, D. K., et al. (2002) · American Journal of Public Health · doi:10.2105/ajph.92.9.1430 · Cited by 229 · see citing works
Self-citationSchool air quality related to dry cough, rhinitis and nasal patency in children
Simoni, M., Annesi‐Maesano, I., Sigsgaard, T., et al. (2010) · European Respiratory Journal · doi:10.1183/09031936.00016309 · Cited by 213 · see citing works
Hospital Ventilation and Risk for Tuberculous Infection in Canadian Health Care Workers
Menzies, D., Fanning, A., Yuan, L., FitzGerald, J. M., & and the Canadian Collaborative Group in Nosocomial Transmission of TB* (2000) · Annals of Internal Medicine · doi:10.7326/0003-4819-133-10-200011210-00010 · Cited by 212 · see citing works
Mi, Y.-H., Norbäck, D., Tao, J., Mi, Y.-L., & Ferm, M. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00439.x · Cited by 211 · see citing works
Association between ventilation rates in 390 Swedish homes and allergic symptoms in children
Bornehag, C., Sundell, J., Hagerhed‐Engman, L., & Sigsgaard, T. (2005) · Indoor Air · doi:10.1111/j.1600-0668.2005.00372.x · Cited by 199 · see citing works
Self-citationQuantitative relationship of sick building syndrome symptoms with ventilation rates
Fisk, W. J., Mirer, A. G., & Mendell, M. J. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2008.00575.x · Cited by 197 · see citing works
Self-citationVentilation in Homes and Bronchial Obstruction in Young Children
Øie, L., Nafstad, P. H. J., Botten, G., Magnus, P. M., & Jaakkola, J. J. K. (1999) · Epidemiology · doi:10.1097/00001648-199905000-00018 · Cited by 186 · see citing works
Menzies, D., & Bourbeau, J. (1997) · New England Journal of Medicine · doi:10.1056/nejm199711203372107 · Cited by 171 · see citing works
Detection of Airborne Rhinovirus and Its Relation to Outdoor Air Supply in Office Environments
Myatt, T. A., Johnston, S. L., Zuo, Z., WAND, M. P., Kebadze, T., Rudnick, S. N., & Milton, D. K. (2004) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200306-760oc · Cited by 164 · see citing works
Building-Associated Risk of Febrile Acute Respiratory Diseases in Army Trainees
Brundage, J. F. (1988) · JAMA · doi:10.1001/jama.1988.03720140028029 · Cited by 158 · see citing works
Air-conditioning and Mortality in Hot Weather
Rogot, E., Sorlie, P. D., & Backlund, E. (1992) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a116413 · Cited by 154 · see citing works
The Effect of Varying Levels of Outdoor-Air Supply on the Symptoms of Sick Building Syndrome
Menzies, R., Tamblyn, R. M., Farant, J.-P., Hanley, J. A., Nunes, F., & Tamblyn, R. T. (1993) · New England Journal of Medicine · doi:10.1056/nejm199303253281201 · Cited by 148 · see citing works
Erdmann, C. A., & Apte, M. G. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00298.x · Cited by 147 · see citing works
New Ventilation Systems at Select Schools in Sweden—Effects on Asthma and Exposure
Smedje, G., & Norbäck, D. (2000) · Archives of Environmental Health An International Journal · doi:10.1080/00039890009603380 · Cited by 140 · see citing works
Wargocki, P. L., Wyon, D. P., & Fanger, P. O. (2004) · Indoor Air · doi:10.1111/j.1600-0668.2004.00304.x · Cited by 137 · see citing works
Jaakkola, J. J. K., Heinoneon, O. P., & Seppänen, O. (1991) · Indoor Air · doi:10.1111/j.1600-0668.1991.02-12.x · Cited by 132 · see citing works
Relationships Between Ventilation and Indoor Air Quality: A Review
Godish, T., & Spengler, J. D. (1996) · Indoor Air · doi:10.1111/j.1600-0668.1996.00010.x · Cited by 122 · see citing works
Self-citationThe work environment and workers' health in four large office buildings.
Chao, H. J., Schwartz, J. D., Milton, D. K., & Burge, H. A. (2003) · Environmental Health Perspectives · doi:10.1289/ehp.5697 · Cited by 120 · see citing works
Building characteristics, indoor air quality and recurrent wheezing in very young children (BAMSE)
Emenius, G., Svartengren, M., Korsgaard, J., Nordvall, L., Pershagen, G., & Wickman, M. C. (2003) · Indoor Air · doi:10.1046/j.1600-0668.2003.00207.x · Cited by 114 · see citing works
Norbäck, D., & Nordström, K. (2008) · International Archives of Occupational and Environmental Health · doi:10.1007/s00420-008-0301-9 · Cited by 110 · see citing works
Zuraimi, M. S., Tham, K. W., Chew, F. T., & Ooi, P. L. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2007.00480.x · Cited by 102 · see citing works
House‐dust mites and associated environmental conditions in Danish homes
Harving, H., Korsgaard, J., & Dahl, R. (1993) · Allergy · doi:10.1111/j.1398-9995.1993.tb00694.x · Cited by 102 · see citing works
Stenberg, B., Eriksson, N., Höög, J., Sundell, J., & Wall, S. (1994) · International Journal of Epidemiology · doi:10.1093/ije/23.6.1190 · Cited by 102 · see citing works
Self-citationVentilation in homes infested by house‐dust mites
Sundell, J., Wickman, M. C., Pershagen, G., & Nordvall, S. L. (1995) · Allergy · doi:10.1111/j.1398-9995.1995.tb05065.x · Cited by 83 · see citing works
Self-citationWålinder, R., Norbäck, D., Wieslander, G., Smedje, G., Erwall, C., & Venge, P. (1998) · International Archives of Occupational and Environmental Health · doi:10.1007/s004200050309 · Cited by 74 · see citing works
Outdoor ozone and building-related symptoms in the BASE study
Apte, M. G., Buchanan, I. S. H., & Mendell, M. J. (2008) · Indoor Air · doi:10.1111/j.1600-0668.2008.00521.x · Cited by 73 · see citing works
Sundell, J., Lindvall, T., & Stenberg, B. (1994) · Environment International · doi:10.1016/0160-4120(94)90141-4 · Cited by 70 · see citing works
Self-citationKorver, W. O. E. (2001) · Elsevier eBooks · doi:10.1016/b978-0-8155-1449-7.50011-6 · Cited by 69 · see citing works
Ventilation rate in office buildings and sick building syndrome.
Jaakkola, J. J. K., & Miettinen, P. (1995) · Occupational and Environmental Medicine · doi:10.1136/oem.52.11.709 · Cited by 68 · see citing works
Sundell, J., Lindvall, T., Stenberg, B., & Wall, S. (1994) · Indoor Air · doi:10.1111/j.1600-0668.1994.t01-2-00003.x · Cited by 56 · see citing works
Self-citationNasal Mucosal Swelling in Relation to Low Air Exchange Rate in Schools
Wålinder, R., Norbäck, D., Wieslander, G., Smedje, G., & Erwall, C. (1997) · Indoor Air · doi:10.1111/j.1600-0668.1997.t01-1-00005.x · Cited by 48 · see citing works
Air recirculation and sick building syndrome: a blinded crossover trial.
Jaakkola, J. J. K., Tuomaala, P., & Seppänen, O. (1994) · American Journal of Public Health · doi:10.2105/ajph.84.3.422 · Cited by 39 · see citing works
Jaakkola, J. J. K., Reinikainen, L. M., Heinonen, O. P., Majanen, A., & Seppänen, O. (1991) · Environment International · doi:10.1016/0160-4120(91)90025-l · Cited by 34 · see citing works
Building-associated risk of febrile acute respiratory diseases in Army trainees
Brundage, J. F. (1988) · JAMA · doi:10.1001/jama.259.14.2108 · Cited by 34 · see citing works
Heat wave mortality in nursing homes
Marmor, M. F. (1978) · Environmental Research · doi:10.1016/0013-9351(78)90065-8 · Cited by 30 · see citing works
Nasal Congestion in Relation to Low Air Exchange Rate in Schools: Evaluation by Acoustic Rhinometry
Wålinder, R., Norbäck, D., Wieslander, G., Smedje, G., & Erwall, C. (1997) · Acta Oto-Laryngologica · doi:10.3109/00016489709113467 · Cited by 24 · see citing works
(1937) · BMJ · doi:10.1136/bmj.2.4011.1024 · Cited by 14 · see citing works
School Ventilation—Principles and Practices
Duffield, T. J. (1932) · American Journal of Public Health and the Nations Health · doi:10.2105/ajph.22.1.115-b · Cited by 3 · see citing works
Flagged first, then by citations
Research works printed but not linked: 6
- [26]26. Janssen, J.E. (1999) The history of ventila- tion and temperature control, ASHRAE Journal, 41, 48-70.
- [27]27. Jennings, B.H. and Armstrong, J.A. (1971) Ventilation theory and practice, ASHRAE Transactions, 77, 50-60.
- [28]28. Klauss, A.K., Tull, R.H., Roots, L.M. and Pfafflin, J.R. (1970) History of changing concepts in ventilation requirements, ASHRAE Journal, 12, 51-55.
- [47]47. Stanke, D. (1999) Ventilation through the years: a perspective, ASHRAE Journal, 41, 40-43.
- [52]52. Tredgold, T. (1836) Principles of Warming and Ventilation -Ventilating Public Buildings, 3rd edition, London, M.
- [62]62. Yaglou, C.P., Riley, E.C. and Coggins, D.I. (1936) Ventilation requirements, ASHVE Transactions, 42, 133-162.
Cited by
Sorted by citations
Transmissibility and transmission of respiratory viruses
Leung, N. H. L. (2021) · Nature Reviews Microbiology · doi:10.1038/s41579-021-00535-6 · Cited by 890 · see citing works
Batterman, S. (2017) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph14020145 · Cited by 271 · see citing works
Persily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249 · see citing works
Indoor air changes and potential implications for SARS-CoV-2 transmission
Allen, J. G., & Ibrahim, A. M. (2021) · JAMA · doi:10.1001/jama.2021.5053 · Cited by 208 · see citing works
COVID-19 has redefined airborne transmission
Tang, J. W., Marr, L. C., Li, Y., & Dancer, S. J. (2021) · BMJ · doi:10.1136/bmj.n913 · Cited by 171 · see citing works
Self-citationTotal Concentrations of Virus and Bacteria in Indoor and Outdoor Air
Prussin, A. J., Garcia, E. B., & Marr, L. C. (2015) · Environmental Science & Technology Letters · doi:10.1021/acs.estlett.5b00050 · Cited by 181 · see citing works
Peng, Z., Deng, W., & Tenorio, R. (2017) · Sustainability · doi:10.3390/su9071180 · Cited by 101 · see citing works
“[8] concluded that the incidence of inflammation, respiratory infections, asthma symptoms, and short-term sickness is enhanced as a result of high exposure to air pollutants.”
BackgroundDevelopment and application of an indoor carbon dioxide metric
Persily, A. (2022) · Indoor Air · doi:10.1111/ina.13059 · Cited by 104 · see citing works
Self-citation
- Authors
- Sundell, J., Levin, H., Nazaroff, W. W., Cain, W. S., Fisk, W. J., Grimsrud, D. T., Gyntelberg, F., Li, Y., Persily, A. K., Pickering, A. C., Samet, J. M., Spengler, J. D., Taylor, S. T., & Weschler, C. J.
- Affiliations
- Technical University of Denmark (DK)
- University of California, Berkeley (US)
- University of California San Diego (US)
- Lawrence Berkeley National Laboratory (US)
- University of Minnesota (US)
- Bispebjerg Hospital (DK)
- University of Hong Kong (HK)
- National Institute of Standards and Technology (US)
- Wythenshawe Hospital (GB)
- University of Southern California (US)
- Harvard University (US)
- Rutgers, The State University of New Jersey (US)
- Corresponding author
- Levin, H.
- ORCID
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2011-02-01
- Volume
- 21
- Issue
- 3
- Pages
- 191-204
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2157363636
- Cited by
- 740
- References
- 56
- Citations by year
- 2026: 49 · 2025: 53 · 2024: 38 · 2023: 49 · 2022: 53 · 2021: 76 · 2020: 71 · 2019: 53 · 2018: 46 · 2017: 45 · 2016: 44 · 2015: 52 · 2014: 46 · 2013: 36 · 2012: 26
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Indoor Air (publishedVersion)
- PubMed (publishedVersion)
- The HKU Scholars Hub (University of Hong Kong) (submittedVersion)
- Topics
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
- Keywords
- ventilation rate, indoor air quality, sick building syndrome, respiratory infections, asthma symptoms, sick leave, indoor pollutants, office buildings, residential ventilation, air changes per hour, building design standards
- MeSH terms
- Asthma, Communicable Diseases, Housing, Humans, Respiratory Tract Infections, Schools, Ventilation, Air Pollution, Indoor, Workplace, Sick Leave, Sick Building Syndrome, Interdisciplinary Communication
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review