Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation
Abstract
This study employs a numerical model to investigate the dispersion characteristics of human exhaled droplets in ventilation rooms. The numerical model is validated by two different experiments prior to the application for the studied cases. Some typical questions on studying dispersion of human exhaled droplets indoors are reviewed and numerical study using the normalized evaporation time and normalized gravitational sedimentation time was performed to obtain the answers. It was found that modeling the transient process from a droplet to a droplet nucleus due to evaporation can be neglected when the normalized evaporation time is <0.051. When the normalized gravitational sedimentation time is <0.005, the influence of ventilation rate could be neglected. However, the influence of ventilation pattern and initial exhaled velocity on the exhaled droplets dispersion is dominant as the airflow decides the droplets dispersion significantly. Besides, the influence of temperature and relative humidity on the dispersion of droplets can be neglected for the droplet with initial diameter <200 microm; while droplet nuclei size plays an important role only for the droplets with initial diameter within the range of 10 microm-100 microm. Practical Implications Dispersion of human exhaled droplets indoor is a key issue when evaluating human exposure to infectious droplets. Results from detailed numerical studies in this study reveal how the evaporation of droplets, ventilation rate, airflow pattern, initial exhaled velocity, and particle component decide the droplet dispersion indoor. The detailed analysis of these main influencing factors on droplet dispersion in ventilation rooms may help to guide (1) the selection of numerical approach, e.g., if the transient process from a droplet to a droplet nucleus due to evaporation should be incorporated to study droplet dispersion, and (2) the selection of ventilation system to minimize the spread of pathogen-laden droplets in an indoor environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Cited by
Airborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Feng, Y., Marchal, T., Sperry, T., & Yi, H. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105585 · Cited by 406
Enhanced spread of expiratory droplets by turbulence in a cough jet
Wei, J., & Li, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.06.018 · Cited by 321
Short-range airborne transmission of expiratory droplets between two people
Liu, L., Li, Y., Nielsen, P. V., Wei, J., & Jensen, R. L. (2017) · Indoor Air · doi:10.1111/ina.12314 · Cited by 310
Metadata
- Authors
- Chen, C., & Zhao, B.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2010-04
- Volume
- 20
- Issue
- 2
- Pages
- 95-111
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2144342661
- Cited by
- 251
- References
- 1
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation. https://app.cochat.ai/papers/10.1111/j.1600-0668.2009.00626.x
- The paper
- Chen, C., & Zhao, B. (2010). Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation. Indoor Air. https://doi.org/10.1111/j.1600-0668.2009.00626.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.