Some questions on dispersion of human exhaled droplets in ventilation room: answers from numerical investigation
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
This study employs a numerical model to investigate the dispersion characteristics of human exhaled droplets in ventilation rooms. The numerical model is validated by two different experiments prior to the application for the studied cases. Some typical questions on studying dispersion of human exhaled droplets indoors are reviewed and numerical study using the normalized evaporation time and normalized gravitational sedimentation time was performed to obtain the answers. It was found that modeling the transient process from a droplet to a droplet nucleus due to evaporation can be neglected when the normalized evaporation time is <0.051. When the normalized gravitational sedimentation time is <0.005, the influence of ventilation rate could be neglected. However, the influence of ventilation pattern and initial exhaled velocity on the exhaled droplets dispersion is dominant as the airflow decides the droplets dispersion significantly. Besides, the influence of temperature and relative humidity on the dispersion of droplets can be neglected for the droplet with initial diameter <200 microm; while droplet nuclei size plays an important role only for the droplets with initial diameter within the range of 10 microm-100 microm. Practical Implications Dispersion of human exhaled droplets indoor is a key issue when evaluating human exposure to infectious droplets. Results from detailed numerical studies in this study reveal how the evaporation of droplets, ventilation rate, airflow pattern, initial exhaled velocity, and particle component decide the droplet dispersion indoor. The detailed analysis of these main influencing factors on droplet dispersion in ventilation rooms may help to guide (1) the selection of numerical approach, e.g., if the transient process from a droplet to a droplet nucleus due to evaporation should be incorporated to study droplet dispersion, and (2) the selection of ventilation system to minimize the spread of pathogen-laden droplets in an indoor environment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The numerical computation of turbulent flows
Launder, B. E., & Spalding, D. B. (1974) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/0045-7825(74)90029-2 · Cited by 12,833
Leal, L. G. (1979) · International Journal of Multiphase Flow · doi:10.1016/0301-9322(79)90021-1 · Cited by 5,300
Aerosol Technology Properties, Behavior, and Measurement of Airborne Particles
LAUCKS, M. L. (2000) · Journal of Aerosol Science · doi:10.1016/s0021-8502(99)00571-6 · Cited by 3,367
Perspective: A Method for Uniform Reporting of Grid Refinement Studies
Roache, P. J. (1994) · Journal of Fluids Engineering · doi:10.1115/1.2910291 · Cited by 3,135
(2006) · A-to-Z Guide to Thermodynamics, Heat and Mass Transfer, and Fluids Engineering · doi:10.1615/atoz.e.evaofdrop · Cited by 2,132
Richardson, L. F. (1911) · Philosophical Transactions of the Royal Society of London. Series A, Containing Papers of a Mathematical or Physical Character · doi:10.1098/rsta.1911.0009 · Cited by 1,440
Evaporation from drops : Part II
Ranz, W. E. (1952) · Chemical engineering progress · Cited by 1,173
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
Cited by
Airborne spread of infectious agents in the indoor environment
Wei, J., & Li, Y. (2016) · American Journal of Infection Control · doi:10.1016/j.ajic.2016.06.003 · Cited by 519
Feng, Y., Marchal, T., Sperry, T., & Yi, H. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105585 · Cited by 406
Enhanced spread of expiratory droplets by turbulence in a cough jet
Wei, J., & Li, Y. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.06.018 · Cited by 321
Short-range airborne transmission of expiratory droplets between two people
Liu, L., Li, Y., Nielsen, P. V., Wei, J., & Jensen, R. L. (2017) · Indoor Air · doi:10.1111/ina.12314 · Cited by 310
Transmission of pathogen-laden expiratory droplets in a coach bus
Yang, X., Ou, C., Yang, H., Liu, L., Song, T., Kang, M., Lin, H., & Hang, J. (2020) · Journal of Hazardous Materials · doi:10.1016/j.jhazmat.2020.122609 · Cited by 191
“The Renormalization Group (RNG) k-ε turbulence model which is one of the most widely-adopted RANS models is employed in terms of accuracy, computing efficiency, and robustness for modeling indoor environments (Hang et al., 2014; Zhang and Li, 2012; Chen and Zhao, 2010; Zhang et al., 2007, 2009).”
InfluentialSneezing and asymptomatic virus transmission
Busco, G., Yang, S. R., Seo, J., & Hassan, Y. A. (2020) · Physics of Fluids · doi:10.1063/5.0019090 · Cited by 188
He, Q., Niu, J., Gao, N., Zhu, T., & Wu, J. (2011) · Building and Environment · doi:10.1016/j.buildenv.2010.08.003 · Cited by 186
“[29] Chen C, Zhao B.”
BackgroundHang, J., Li, Y., & Jin, R. (2014) · Building and Environment · doi:10.1016/j.buildenv.2014.03.029 · Cited by 181
Metadata
- Authors
- Chen, C., & Zhao, B.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2010-04
- Volume
- 20
- Issue
- 2
- Pages
- 95-111
- ISSN
- 0905-6947 (ISSN-L)
- 1600-0668
- OpenAlex
- W2144342661
- Cited by
- 251
- References
- 37
- FWCI
- 4.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).