Transport of expiratory droplets in an aircraft cabin
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
UNLABELLED: The droplets exhaled by an index patient with infectious disease such as influenza or tuberculosis may be the carriers of contagious agents. Indoor environments such as the airliner cabins may be susceptible to infection from such airborne contagious agents. The present investigation computed the transport of the droplets exhaled by the index patient seated in the middle of a seven-row, twin-aisle, fully occupied cabin using the CFD simulations. The droplets exhaled were from a single cough, a single breath, and a 15-s talk of the index patient. The expiratory droplets were tracked by using Lagrangian method, and their evaporation was modeled. It was found that the bulk airflow pattern in the cabin played the most important role on the droplet transport. The droplets were contained in the row before, at, and after the index patient within 30 s and dispersed uniformly to all the seven rows in 4 minutes. The total airborne droplet fraction reduced to 48, 32, 20, and 12% after they entered the cabin for 1, 2, 3, and 4 min, respectively, because of the ventilation from the environmental control system. PRACTICAL IMPLICATIONS: It is critical to predict the risk of airborne infection to take appropriate measures to control and mitigate the risk. Most of the studies in past either assume a homogenous distribution of contaminants or use steady-state conditions. The present study instead provides information on the transient movement of the droplets exhaled by an index passenger in an aircraft cabin. These droplets may contain active contagious agents and can be potent enough to cause infection. The findings can be used by medical professionals to estimate the spatial and temporal distribution of risk of infection to various passengers in the cabin.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical Heat Transfer and Fluid Flow
Patankar, S. V. (2018) · CRC Press eBooks · doi:10.1201/9781482234213 · Cited by 23,360
Numerical Heat Transfer and Fluid Flow
Hsu, C.-J. (1981) · Nuclear Science and Engineering · doi:10.13182/nse81-a20112 · Cited by 15,125
Renormalization group analysis of turbulence. I. Basic theory
Yakhot, V., & Orszag, S. A. (1986) · Journal of Scientific Computing · doi:10.1007/bf01061452 · Cited by 4,265
(2006) · A-to-Z Guide to Thermodynamics, Heat and Mass Transfer, and Fluids Engineering · doi:10.1615/atoz.e.evaofdrop · Cited by 2,132
Renormalization-Group Analysis of Turbulence
Yakhot, V., & Orszag, S. A. (1986) · Physical Review Letters · doi:10.1103/physrevlett.57.1722 · Cited by 1,708
Evaporation from drops : Part II
Ranz, W. E. (1952) · Chemical engineering progress · Cited by 1,173
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
Transmission of the Severe Acute Respiratory Syndrome on Aircraft
Olsen, S. J., Chang, H.-L., Cheung, T. Y.-Y., Tang, A. F.-Y., Fisk, T. L., Ooi, S. P.-L., Kuo, H.-W., Jiang, D. D.-S., Chen, K.-T., Lando, J., et al. (2003) · New England Journal of Medicine · doi:10.1056/nejmoa031349 · Cited by 719
Droplet fate in indoor environments, or can we prevent the spread of infection?
Morawska, L. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00432.x · Cited by 635 · cited 2×
“3 in cabin air (Morawska, 2006).”
BackgroundFlow dynamics and characterization of a cough
Gupta, J. K., Lin, C.-H., & Chen, Q. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2009.00619.x · Cited by 605
Self-citationCharacterizing exhaled airflow from breathing and talking
Gupta, J. K., Lin, C.-H., & Chen, Q. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00623.x · Cited by 564
Self-citationTransmission of infectious diseases during commercial air travel
Mangili, A., & Gendreau, M. A. (2005) · The Lancet · doi:10.1016/s0140-6736(05)71089-8 · Cited by 535
Influenza Virus in Human Exhaled Breath: An Observational Study
Fabian, P., McDevitt, J. J., DeHaan, W. H., Fung, R. O. P., Cowling, B. J., Chan, K. H., Leung, G. M., & Milton, D. K. (2008) · PLoS ONE · doi:10.1371/journal.pone.0002691 · Cited by 496
The Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473
Zhang, Z., & Chen, Q. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.01.014 · Cited by 422 · cited 1×
“, 2009), while the Lagrangian method to determine particle dispersion pattern (Zhang and Chen 2006; Zhang and Chen 2007d and Wan et al., 2009).”
MethodSelf-citationInhaling to mitigate exhaled bioaerosols
Edwards, D. A., Man, J. C., Brand, P., Katstra, J. P., Sommerer, K., Stone, H. A., Nardell, E., & Scheuch, G. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0408159101 · Cited by 362 · cited 1×
“There is a wide range of literature on expiratory droplet size and concentration measurements for coughing, breathing, and talking processes (Duguid, 1946; Fairchild and Stampfer, 1987; Edwards et al., 2004; Yang et al., 2007 and Fabian et al., 2008).”
BackgroundTransmission of Multidrug-Resistant Mycobacterium tuberculosis during a Long Airplane Flight
Kenyon, T. A., Valway, S. E., Ihle, W. W., Onorato, I. M., & Castro, K. G. (1996) · New England Journal of Medicine · doi:10.1056/nejm199604113341501 · Cited by 357
Particle Concentration in Exhaled Breath
FAIRCHILD, C. I., & STAMPFER, J. F. (1987) · American Industrial Hygiene Association Journal · doi:10.1080/15298668791385868 · Cited by 175
Responding to Medical Events during Commercial Airline Flights
Gendreau, M. A., & DeJohn, C. (2002) · New England Journal of Medicine · doi:10.1056/nejmra012774 · Cited by 161
Wan, M. P., Sze-To, G. N., Chao, C. Y. H., Fang, L., & Melikov, A. K. (2009) · Aerosol Science and Technology · doi:10.1080/02786820802641461 · Cited by 132
Temperatures of expired air under varying climatic conditions
Höppe, P. (1981) · International Journal of Biometeorology · doi:10.1007/bf02184460 · Cited by 128
Sze To, G. N., Wan, M. P., Chao, C. Y. H., Fang, L., & Melikov, A. (2009) · Aerosol Science and Technology · doi:10.1080/02786820902736658 · Cited by 117
Transport and Removal of Expiratory Droplets in Hospital Ward Environment
Chao, C. Y. H., Wan, M. P., & To, G. N. S. (2008) · Aerosol Science and Technology · doi:10.1080/02786820802104973 · Cited by 93 · cited 1×
“A recent experimental study by Chao et al. (2008) indicated that the particle deposition fraction for this range of droplet diameter was around 10%-20% for 6-12 ACH exchange rates in hospital environment.”
BackgroundHUMAN PULMONARY SECRETIONS IN HEALTH AND DISEASE
Potter, J. L., Matthews, L. W., Lemm, J., & Spector, S. S. (1963) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1963.tb16677.x · Cited by 91
Optimal Sensor Placement for Airborne Contaminant Detection in an Aircraft Cabin
Zhang, T., Chen, Q., & Lin, C. (2007) · Science and Technology for the Built Environment · doi:10.1080/10789669.2007.10390980 · Cited by 53
Self-citation
Cited by
Feng, Y., Marchal, T., Sperry, T., & Yi, H. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105585 · Cited by 406
Short-range airborne transmission of expiratory droplets between two people
Liu, L., Li, Y., Nielsen, P. V., Wei, J., & Jensen, R. L. (2017) · Indoor Air · doi:10.1111/ina.12314 · Cited by 310
Airflow Dynamics of Human Jets: Sneezing and Breathing - Potential Sources of Infectious Aerosols
Tang, J. W., Nicolle, A. D., Klettner, C. A., Pantelic, J., Wang, L., Suhaimi, A. B., Tan, A. Y. L., Ong, G. W. X., Su, R., Sekhar, C., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0059970 · Cited by 284
Modeling the evaporation and dispersion of airborne sputum droplets expelled from a human cough
Redrow, J., Mao, S., Celik, I., Posada, J. A., & Feng, Z.-G. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.04.011 · Cited by 221
Browne, A., St-Onge Ahmad, S., Beck, C. R., & Nguyen-Van-Tam, J. S. (2016) · Journal of Travel Medicine · doi:10.1093/jtm/tav002 · Cited by 194
“The risk of transmission is theoretically highest in air passengers seated close to an index case [26, 27, 28] and increases with flight duration [5, 27].”
Background
Metadata
- Authors
- Gupta, J. K., Lin, C.-H., & Chen, Q.
- Venue
- Indoor Air
- Publisher
- Hindawi Limited
- Published
- 2011-01-05
- Volume
- 21
- Issue
- 1
- Pages
- 3-11
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2151034647
- Cited by
- 214
- References
- 25
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.