The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Flow dynamics and characterization of a cough
Open accessAbstract
UNLABELLED: Airborne disease transmission has always been a topic of wide interests in various fields for decades. Cough is found to be one of the prime sources of airborne diseases as it has high velocity and large quantity of droplets. To understand and characterize the flow dynamics of a cough can help to control the airborne disease transmission. This study has measured flow dynamics of coughs with human subjects. The flow rate variation of a cough with time can be represented as a combination of gamma-probability-distribution functions. The variables needed to define the gamma-probability-distribution functions can be represented by some medical parameters. A robust multiple linear regression analysis indicated that these medical parameters can be obtained from the physiological details of a person. However, the jet direction and mouth opening area during a cough seemed not related to the physiological parameters of the human subjects. Combining the flow characteristics reported in this study with appropriate virus and droplet distribution information, the infectious source strength by coughing can be evaluated. PRACTICAL IMPLICATIONS: There is a clear need for the scientific community to accurately predict and control the transmission of airborne diseases. Transportation of airborne viruses is often predicted using Computational Fluid Dynamics (CFD) simulations. CFD simulations are inexpensive but need accurate source boundary conditions for the precise prediction of disease transmission. Cough is found to be the prime source for generating infectious viruses. The present study was designed to develop an accurate source model to define thermo-fluid boundary conditions for a cough. The model can aid in accurately predicting the disease transmission in various indoor environments, such as aircraft cabins, office spaces and hospitals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Chao, C. Y. H., Li, Y., & Katoshevski, D. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.11.002 · Cited by 1,129
Chao, C. Y. H., Wan, M. P., Morawska, L., Johnson, G. R., Ristovski, Z. D., Hargreaves, M., Mengersen, K., Corbett, S., Li, Y., Xie, X., et al. (2009) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2008.10.003 · Cited by 1,087
Respiratory function tests; normal values at median altitudes and the prediction of normal results.
Goldman, H. I., & Becklake, M. R. (1959) · PubMed · doi:10.1164/artpd.1959.79.4.457 · Cited by 954
The size and the duration of air-carriage of respiratory droplets and droplet-nuclei
Duguid, J. P. (1946) · Epidemiology and Infection · doi:10.1017/s0022172400019288 · Cited by 850
Holmes, N. S., & Morawska, L. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.003 · Cited by 713
The size distribution of droplets in the exhaled breath of healthy human subjects
PAPINENI, R. S., & ROSENTHAL, F. S. (1997) · Journal of Aerosol Medicine · doi:10.1089/jam.1997.10.105 · Cited by 690
Droplet fate in indoor environments, or can we prevent the spread of infection?
Morawska, L. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2006.00432.x · Cited by 635
Estimation of human body surface area from height and weight.
Gehan, E. A., & George, S. L. (1970) · PubMed · Cited by 577
The Size and Concentration of Droplets Generated by Coughing in Human Subjects
Yang, S., Lee, G. W. M., Chen, C.-M., Wu, C.-C., & Yu, K.-P. (2007) · Journal of Aerosol Medicine · doi:10.1089/jam.2007.0610 · Cited by 473
Zhu, S., Kato, S., & Yang, J.-H. (2006) · Building and Environment · doi:10.1016/j.buildenv.2005.06.024 · Cited by 428
Cited by
Violent expiratory events: on coughing and sneezing
Bourouiba, L., Dehandschoewercker, E., & Bush, J. W. M. (2014) · Journal of Fluid Mechanics · doi:10.1017/jfm.2014.88 · Cited by 828
The role of particle size in aerosolised pathogen transmission: a review
Gralton, J., Tovey, E., McLaws, M.-L., & Rawlinson, W. D. (2011) · Journal of Infection · doi:10.1016/j.jinf.2010.11.010 · Cited by 665
Characterizing exhaled airflow from breathing and talking
Gupta, J. K., Lin, C.-H., & Chen, Q. (2010) · Indoor Air · doi:10.1111/j.1600-0668.2009.00623.x · Cited by 564
Self-citationFeng, Y., Marchal, T., Sperry, T., & Yi, H. (2020) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2020.105585 · Cited by 406
Characterizations of particle size distribution of the droplets exhaled by sneeze
Han, Z. Y., Weng, W. G., & Huang, Q. Y. (2013) · Journal of The Royal Society Interface · doi:10.1098/rsif.2013.0560 · Cited by 383
Metadata
- Authors
- Gupta, J. K., Lin, C.-H., & Chen, Q.
- Venue
- Indoor Air
- Publisher
- Wiley
- Published
- 2009-07-21
- Volume
- 19
- Issue
- 6
- Pages
- 517-525
- ISSN
- 0905-6947 (ISSN-L)
- OpenAlex
- W2105772427
- Cited by
- 605
- References
- 19
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow dynamics and characterization of a cough. https://app.cochat.ai/papers/10.1111/j.1600-0668.2009.00619.x
- The paper
- Gupta, J. K., Lin, C.-H., & Chen, Q. (2009). Flow dynamics and characterization of a cough. Indoor Air. https://doi.org/10.1111/j.1600-0668.2009.00619.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.