Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 170

The DOI matches its Crossref record.

Glass ionomer and resin‐based fissure sealants: a clinical study

MEJÀRE*, INGEGERD, MJÖR, IVAR A. · 1990 · European Journal of Oral Sciences

Abstract

The aim of this study was to compare the retention rate of a glass ionomer cement formulated for fissure sealing with two resin‐based sealants. 208 occlusal fissures of permanent molars and premolars were sealed with either Fuji III, Delton or Concise WS by four dentists. Clinical assessments and a replica scoring technique were used to register the performance of the sealants at baseline, after 6–12 months, and then yearly up to 5 yr. As judged clinically, 61% of the glass ionomer sealants were lost within 6–12 months and 84% after 30–36 months. Although total loss was recorded clinically for the majority of the glass ionomer sealants, some retained sealant was observed in the tooth replicas in 93%, of them. The clinical evaluation of the resin‐based sealants showed an average complete retention rate of 90% after 4.5–5 yr. The corresponding figure with the replica technique was 58%. Caries was recorded in 5% of the resin‐based and in none of the glass ionomer sealed surfaces.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0722.1990.tb00983.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 170

Metadata

Authors
MEJÀRE*, I., & MJÖR, I. A.
Venue
European Journal of Oral Sciences
Publisher
Wiley
Published
1990-08
Volume
98
Issue
4
Pages
345-350
ISSN
  • 0029-845X (ISSN-L)
  • 0909-8836
  • 1600-0722
OpenAlex
W2080544493
Cited by
170
References
0
FWCI
4.09
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Glass ionomer and resin‐based fissure sealants: a clinical study. https://app.cochat.ai/papers/10.1111/j.1600-0722.1990.tb00983.x
The paper
MEJÀRE*, I., & MJÖR, I. A. (1990). Glass ionomer and resin‐based fissure sealants: a clinical study. European Journal of Oral Sciences. https://doi.org/10.1111/j.1600-0722.1990.tb00983.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.