Saliva and serum samples were collected from eight healthy volunteers every two hours during a 26‐hour period. Melatonin concentrations were measured by radioimmunoassay after chloroform extraction using radioiodinated melatonin as a tracer. Five of the subjects had high serum melatonin levels at night (peak levels higher than 75 pg/ml); in three subjects the highest serum melatonin concentration was 20‐40 pg/ml. All subjects had low levels (<10 pg/ml) during the day. The correlations between salivary and serum levels were calculated. The regression line y =0.33×+ 3.7 pg/ml, r= 0.95, P <0.001, was obtained for all detectable value pairs (n= 73). The regression and correlation coefficients were almost equal for the peak values of melatonin and during the rising and descending phases of the secretion patterns. However, no significant correlation was found between low daytime salivary and serum concentrations when calculated separately. In the five high‐secretors the melatonin levels in saliva reflected reliably the changes in serum, but in the three low‐secretors the correlation between salivary and serum melatonin was not significant. The proportion of melatonin found in saliva decreased with increasing serum melatonin levels. Circadian rhythm parameters were estimated by single cosinor analysis. The acrophases did not differ significantly within a subject in the concomitant measurements of serum and salivary melatonin. The measurements of salivary melatonin levels seem valid for studies on melatonin rhythms, but the melatonin concentrations measured in saliva do not always consistently reflect the absolute concentrations in blood.
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Saliva and serum samples were collected from eight healthy volunteers every two hours during a 26-hour period. Melatonin concentrations were measured by radioimmunoassay after chloroform extraction using radioiodinated melatonin as a tracer. Five of the subjects had high serum melatonin levels at night (peak levels higher than 75 pg/ml); in three subjects the highest serum melatonin concentration was 20-40 pg/ml. All subjects had low levels (less than 10 pg/ml) during the day. The correlations between salivary and serum levels were calculated. The regression line y = 0.33x + 3.7 pg/ml, r = 0.95, P less than 0.001, was obtained for all detectable value pairs (n = 73). The regression and correlation coefficients were almost equal for the peak values of melatonin and during the rising and descending phases of the secretion patterns. However, no significant correlation was found between low daytime salivary and serum concentrations when calculated separately. In the five high-secretors the melatonin levels in saliva reflected reliably the changes in serum, but in the three low-secretors the correlation between salivary and serum melatonin was not significant. The proportion of melatonin found in saliva decreased with increasing serum melatonin levels. Circadian rhythm parameters were estimated by single cosinor analysis. The acrophases did not differ significantly within a subject in the concomitant measurements of serum and salivary melatonin. The measurements of salivary melatonin levels seem valid for studies on melatonin rhythms, but the melatonin concentrations measured in saliva do not always consistently reflect the absolute concentrations in blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Circadian Rhythm of Plasma Melatonin During the Normal Menstrual Cycle and in Amenorrheic Women*
BRZEZINSKI, A., LYNCH, H. J., SEIBEL, M. M., DENG, M. H., NADER, T. M., & WURTMAN, R. J. (1988) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jcem-66-5-891 · Cited by 177
Cited by
Pineal Melatonin: Cell Biology of Its Synthesis and of Its Physiological Interactions*
REITER, R. J. (1991) · Endocrine Reviews · doi:10.1210/edrv-12-2-151 · Cited by 2,192
Extrapineal melatonin: sources, regulation, and potential functions
Acuña-Castroviejo, D., Escames, G., Venegas, C., Díaz-Casado, M. E., Lima-Cabello, E., López, L. C., Rosales-Corral, S., Tan, D.-X., & Reiter, R. J. (2014) · Cellular and Molecular Life Sciences · doi:10.1007/s00018-014-1579-2 · Cited by 1,076
Carlson, L. E., Speca, M., Patel, K. D., & Goodey, E. (2004) · Psychoneuroendocrinology · doi:10.1016/s0306-4530(03)00054-4 · Cited by 740
Salivary Melatonin as a Circadian Phase Marker: Validation and Comparison to Plasma Melatonin
Voultsios, A., Kennaway, D. J., & Dawson, D. (1997) · Journal of Biological Rhythms · doi:10.1177/074873049701200507 · Cited by 467
Melatonin: From Basic Research to Cancer Treatment Clinics
Vijayalaxmi, Thomas, C. R., Reiter, R. J., & Herman, T. S. (2002) · Journal of Clinical Oncology · doi:10.1200/jco.2002.11.004 · Cited by 361
Metadata
- Authors
- Laakso, M., Porkka‐Heiskanen, T., Alila, A., Stenberg, D., & Johansson, G.
- Venue
- Journal of Pineal Research
- Publisher
- Wiley
- Published
- 1990-08
- Volume
- 9
- Issue
- 1
- Pages
- 39-50
- ISSN
- 0742-3098 (ISSN-L)
- 1600-079X
- OpenAlex
- W102667020
- Cited by
- 106
- References
- 1
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Saliva and serum samples were collected from eight healthy volunteers every two hours during a 26‐hour period. Melatonin concentrations were measured by radioimmunoassay after chloroform extraction using radioiodinated melatonin as a tracer. Five of the subjects had high serum melatonin levels at night (peak levels higher than 75 pg/ml); in three subjects the highest serum melatonin concentration was 20‐40 pg/ml. All subjects had low levels (<10 pg/ml) during the day. The correlations between salivary and serum levels were calculated. The regression line y =0.33×+ 3.7 pg/ml, r= 0.95, P <0.001, was obtained for all detectable value pairs (n= 73). The regression and correlation coefficients were almost equal for the peak values of melatonin and during the rising and descending phases of the secretion patterns. However, no significant correlation was found between low daytime salivary and serum concentrations when calculated separately. In the five high‐secretors the melatonin levels in saliva reflected reliably the changes in serum, but in the three low‐secretors the correlation between salivary and serum melatonin was not significant. The proportion of melatonin found in saliva decreased with increasing serum melatonin levels. Circadian rhythm parameters were estimated by single cosinor analysis. The acrophases did not differ significantly within a subject in the concomitant measurements of serum and salivary melatonin. The measurements of salivary melatonin levels seem valid for studies on melatonin rhythms, but the melatonin concentrations measured in saliva do not always consistently reflect the absolute concentrations in blood. https://app.cochat.ai/papers/10.1111/j.1600-079x.1990.tb00692.x
- The paper
- Laakso, M., Porkka‐Heiskanen, T., Alila, A., Stenberg, D., & Johansson, G. (1990). Saliva and serum samples were collected from eight healthy volunteers every two hours during a 26‐hour period. Melatonin concentrations were measured by radioimmunoassay after chloroform extraction using radioiodinated melatonin as a tracer. Five of the subjects had high serum melatonin levels at night (peak levels higher than 75 pg/ml); in three subjects the highest serum melatonin concentration was 20‐40 pg/ml. All subjects had low levels (<10 pg/ml) during the day. The correlations between salivary and serum levels were calculated. The regression line y =0.33×+ 3.7 pg/ml, r= 0.95, P <0.001, was obtained for all detectable value pairs (n= 73). The regression and correlation coefficients were almost equal for the peak values of melatonin and during the rising and descending phases of the secretion patterns. However, no significant correlation was found between low daytime salivary and serum concentrations when calculated separately. In the five high‐secretors the melatonin levels in saliva reflected reliably the changes in serum, but in the three low‐secretors the correlation between salivary and serum melatonin was not significant. The proportion of melatonin found in saliva decreased with increasing serum melatonin levels. Circadian rhythm parameters were estimated by single cosinor analysis. The acrophases did not differ significantly within a subject in the concomitant measurements of serum and salivary melatonin. The measurements of salivary melatonin levels seem valid for studies on melatonin rhythms, but the melatonin concentrations measured in saliva do not always consistently reflect the absolute concentrations in blood. Journal of Pineal Research. https://doi.org/10.1111/j.1600-079x.1990.tb00692.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.