CoChat

Viscoelastic response to repeated static stretching in the human hamstring muscle

Magnusson, S. P., Simonsen, E. B., Aagaard, P., Gleim, G. W., McHugh, M. P., Kjaer, M. · 1995 · Scandinavian Journal of Medicine & Science in Sports
Cited by 225

The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.

Abstract

The purpose of this study was (1) to evaluate the reproducibility of a new method of measuring passive resistance to stretch in the human hamstring muscle group, in vivo, using a test re‐test protocol and 2) to examine the effect of repeated stretches. Passive resistance offered by the hamstring muscle group during knee extension was measured in 10 subjects as knee flexion moment (Nm) using a KinCom dynamometer. The knee was passively extended at 5 deg/s to the final position where it remained stationary for 90 s (static phase). EMG of the hamstring muscle was also measured. The test re‐test protocol included 2 tests (tests 1 and 2) administered 1 h apart. On a separate occasion 5 consecutive static stretches were administered (stretches 1–5) separted by 30 s. Stretch 6 was administered one hour after stretch 5. In the static phase passive resistance did not differ between test 1 and test 2. Resistance declined in both tests 1 and 2, whereas EMG activity remained unchanged. The decline in resistance was significant up to 45 s. For the repeated stretches there was an effect of time (90 s) and stretch (1–5) with a significant interaction i.e., resistance diminished with stretches, and the 90‐s decline was less as more stretches were performed. Passive resistance in stretch 6 was lower than in stretch 1. The present study has demonstrated a reliable method for studying resistance to stretch of the human hamstring muscle group. A viscoelastic response of the human hamstring muscle was shown. With 5 repeated stretches, resistance to stretch diminished and each stretch exibited a viscoelastic response, albeit less with each subsequent stretch. The effect of 5 repeated stretches was significant 1 h later.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1600-0838.1995.tb00056.x

Cites

20 of 20 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 225

Metadata

Authors
Magnusson, S. P., Simonsen, E. B., Aagaard, P., Gleim, G. W., McHugh, M. P., & Kjaer, M.
Venue
Scandinavian Journal of Medicine & Science in Sports
Publisher
Wiley
Published
1995-12
Volume
5
Issue
6
Pages
342-347
ISSN
  • 0905-7188 (ISSN-L)
  • 1600-0838
OpenAlex
W2081798722
Cited by
225
References
20
FWCI
3.59
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.