The DOI matches its Crossref record.
Structure–function relationships of entheses in relation to mechanical load and exercise
Abstract
Entheses are regions of high‐stress concentration that are commonly affected by overuse injuries in sport. This review summarizes current knowledge of their structure–function relationships – at the macroscopic, microscopic and molecular levels. Consideration is given to how stress concentration is reduced at fibrocartilaginous entheses by various adaptations which ensure that stress is dissipated away from the hard–soft tissue interface. The fundamental question of how a tendon or ligament is anchored to bone is addressed – particularly in relation to the paucity of compact bone at fibrocartilaginous entheses. The concept of an “enthesis organ” is reviewed – i.e. the idea of a collection of tissues adjacent to the enthesis itself, which jointly serve a common function – stress dissipation. The archetypal enthesis organ is that of the Achilles tendon and the functional importance of its subtendinous bursa, with its fibrocartilaginous walls and protruding fat pad, is emphasized. The distribution of adipose tissue elsewhere at entheses is also explained and possible functions of insertion‐site fat are evaluated. Finally, a brief consideration is given to enthesopathies, with attention drawn to the possibility of degenerative changes affecting other regions of an enthesis organ, besides the enthesis itself.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Structure‐function relationships in tendons: a review
Benjamin, M., Kaiser, E., & Milz, S. (2008) · Journal of Anatomy · doi:10.1111/j.1469-7580.2008.00864.x · Cited by 506
Self-citationThe microstructure and micromechanics of the tendon–bone insertion
Rossetti, L., Kuntz, L. A., Kunold, E., Schock, J., Müller, K. W., Grabmayr, H., Stolberg-Stolberg, J., Pfeiffer, F., Sieber, S. A., Burgkart, R., et al. (2017) · Nature Materials · doi:10.1038/nmat4863 · Cited by 401
Strategies to engineer tendon/ligament-to-bone interface: Biomaterials, cells and growth factors
Font Tellado, S., Balmayor, E. R., & Van Griensven, M. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.03.004 · Cited by 286
Towards human exploration of space: the THESEUS review series on muscle and bone research priorities
Lang, T., Van Loon, J. J. W. A., Bloomfield, S., Vico, L., Chopard, A., Rittweger, J., Kyparos, A., Blottner, D., Vuori, I., Gerzer, R., et al. (2017) · npj Microgravity · doi:10.1038/s41526-017-0013-0 · Cited by 141
Metadata
- Authors
- Shaw, H. M., & Benjamin, M.
- Venue
- Scandinavian Journal of Medicine & Science in Sports
- Publisher
- Wiley
- Published
- 2007-05-09
- Volume
- 17
- Issue
- 4
- Pages
- 303-315
- ISSN
- 0905-7188 (ISSN-L)
- 1600-0838
- OpenAlex
- W1486716069
- Cited by
- 227
- References
- 0
- FWCI
- 4.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Structure–function relationships of entheses in relation to mechanical load and exercise. https://app.cochat.ai/papers/10.1111/j.1600-0838.2007.00689.x
- The paper
- Shaw, H. M., & Benjamin, M. (2007). Structure–function relationships of entheses in relation to mechanical load and exercise. Scandinavian Journal of Medicine & Science in Sports. https://doi.org/10.1111/j.1600-0838.2007.00689.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.