Cited by 69Physical Activity and HealthContext-Aware Activity Recognition SystemsCardiovascular and exercise physiology

Concurrent validity of the PAM accelerometer relative to the MTI Actigraph using oxygen consumption as a reference

Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., Koppes, L. L. J.·2009·Scandinavian Journal of Medicine & Science in Sports

Abstract

The purpose of this study was to examine the concurrent validity of the Personal Activity Monitor (PAM) accelerometer relative to the Actigraph accelerometer using oxygen consumption as a reference, and to assess the test–retest reliability of the PAM. Thirty‐two fit, normal weight adults (aged 21–54) performed two activities, treadmill walking and stair walking, while wearing the PAM, the Actigraph and the Cosmed K4b 2. Correlation coefficients and agreement in absolute energy expenditure (EE) levels between PAM, Actigraph and Cosmed were calculated. The test–retest reliability was examined among 296 PAM's using a laboratory shaker. Intraclass correlation coefficients (ICC) and coefficient of variation (CV) were determined. Correlations for treadmill walking and stair walking, respectively, were r2=0.95 and r2=0.65 for PAM with Actigraph, r2=0.82 and r2=0.93 for PAM with VO 2 and r2=0.64 and 0.74 for Actigraph with VO 2. Both the PAM and Actigraph underestimated EE during treadmill and stair walking by a substantial amount. The test–retest reliability of the PAM was high [ICC=0.80; 95% confidence interval (CI) (0.28;0.92) and intra‐CV=1.5%]. The PAM and Actigraph accelerometer are comparable in assessing bodily movement during treadmill and stair walking. The PAM is a valid device to rank subjects in EE and can be useful in collecting objective data to monitor habitual physical activity.

Integrity signals

Registry

Crossref · 10.1111/j.1600-0838.2007.00740.x

Cites

34 of 34 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

2 of the 36 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Slootmaker, S. M., Chin A Paw, M. J. M., Schuit, A. J., Van Mechelen, W., & Koppes, L. L. J.
Affiliations
  • Netherlands Organisation for Applied Scientific Research (NL)
  • National Institute for Public Health and the Environment (NL)
  • Amsterdam Public Health (NL)
Venue
Scandinavian Journal of Medicine & Science in Sports
Publisher
Wiley
Published
2009-01-28
Volume
19
Issue
1
Pages
36-43
ISSN
  • 0905-7188 (ISSN-L)
  • 1600-0838
OpenAlex
W2168439687
Cited by
69
References
36
Citations by year
2026: 1 · 2024: 2 · 2022: 4 · 2021: 2 · 2020: 4 · 2019: 3 · 2018: 2 · 2017: 4 · 2016: 6 · 2015: 5 · 2014: 4 · 2013: 3 · 2012: 8
FWCI
5.74
Type
journal article
Language
en
Open access
closed
Locations
  • Scandinavian Journal of Medicine and Science in Sports (publishedVersion)
  • PubMed (publishedVersion)
  • Amsterdam UMC (VU Amsterdam) - Institutional Repository (publishedVersion)
  • Pure Amsterdam UMC (submittedVersion)
  • VU Research Portal (submittedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
  • Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
Keywords
ActiGraph, accelerometer, concurrent validity, test-retest reliability, energy expenditure, oxygen consumption, treadmill walking, stair climbing, physical activity monitoring, underestimation of energy expenditure
MeSH terms
Acceleration, Adult, Female, Humans, Male, Middle Aged, Monitoring, Physiologic, Netherlands, Oxygen Consumption, Reference Values, Reproducibility of Results, Models, Statistical, Exercise, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review