Electrodermal activity by DC potential and AC conductance measured simultaneously at the same skin site
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Background: For a long time, DC conductance has been the most important parameter in electrodermal routine measurements. However, DC current flow polarizes the electrodes, electrolyzes the skin, disturbs the measurement of conductance by possible varying electromotive forces (EMFs) in the circuit, and impedes the registration of the skin endosomatic DC potential. Methods: We therefore present a measuring system where DC current was replaced by a small AC current in a monopolar system, enabling the DC potential and AC conductance to be measured simultaneously at the same skin site. Results: We have also found examples of skin potential (SP) response waveforms with diphasic sharp edges not appearing in the conductance waveforms. The potential responses were found to be more robust with respect to movement artifacts, and the instrumentation could discern whether the indifferent electrode actually was on an inactive skin site. Conclusion: In order to study the generating mechanisms of EDA in detail, the SP must be measured without DC current flow and compared with AC conductance results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boucsein, W. (1992) · doi:10.1007/978-1-4757-5093-5 · Cited by 818
Cited by
Publication recommendations for electrodermal measurements
Society for Psychophysiological Research Ad Hoc Committee on Electrodermal Measures (2012) · Psychophysiology · doi:10.1111/j.1469-8986.2012.01384.x · Cited by 1,288
“Additionally, Grimnes et al. (2011) used a special method for combining SY with SP recordings from a single active electrode at a palmar site together with an indifferent electrode connected to a physiological NaCl bath in which the forearm was immersed.”
BackgroundMethodInfluentialSonner, Z., Wilder, E., Heikenfeld, J., Kasting, G., Beyette, F., Swaile, D., Sherman, F., Joyce, J., Hagen, J., Kelley-Loughnane, N., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4921039 · Cited by 724
Innovations in Electrodermal Activity Data Collection and Signal Processing: A Systematic Review
Posada-Quintero, H. F., & Chon, K. H. (2020) · Sensors · doi:10.3390/s20020479 · Cited by 525
“skin site by using a small AC current in a monopolar system [25].”
Alexithymia and Empathy Predict Changes in Autonomic Arousal During Affective Stimulation
Bogdanov, V. B., Bogdanova, O. V., Gorlov, D. S., Gorgo, Y. P., Dirckx, J. J. J., Makarchuk, M. Y., Schoenen, J., & Critchley, H. (2013) · Cognitive and Behavioral Neurology · doi:10.1097/wnn.0000000000000002 · Cited by 32
“An increase in electrodermal reactivity—another index of raised sympathetic tone (Grimnes et al, 2011)— was reported in healthy people with high alexithymia scores after they listened to music that provoked negative emotions (Grynberg et al, 2012) and in depressed patients with high alexithymia…”
Background
Metadata
- Authors
- Grimnes, S., Jabbari, A., Martinsen, Ø. G., & Tronstad, C.
- Venue
- Skin Research and Technology
- Publisher
- Wiley
- Published
- 2011-01-13
- Volume
- 17
- Issue
- 1
- Pages
- 26-34
- ISSN
- 0909-752X (ISSN-L)
- 1600-0846
- OpenAlex
- W1606260527
- Cited by
- 39
- References
- 1
- FWCI
- 1.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrodermal activity by DC potential and AC conductance measured simultaneously at the same skin site. https://app.cochat.ai/papers/10.1111/j.1600-0846.2010.00459.x
- The paper
- Grimnes, S., Jabbari, A., Martinsen, Ø. G., & Tronstad, C. (2011). Electrodermal activity by DC potential and AC conductance measured simultaneously at the same skin site. Skin Research and Technology. https://doi.org/10.1111/j.1600-0846.2010.00459.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.