Cited by 4Psoriasis: Treatment and PathogenesisDermatology and Skin DiseasesAdvanced Fluorescence Microscopy Techniques

Fluorescent fibre‐optic confocal imaging of lesional and non‐lesional psoriatic skin compared with normal skin in vivo

Suihko, Christian, Serup, Jørgen·2012·Skin Research and Technology

Abstract

Background/aims: Fibre‐optic confocal imaging (FOCI) allows non‐invasive visualization of live skin in vivo. A contrast agent, a fluorophore, is injected in the dermis. FOCI images are optical sections from a horizontal (en face) view. The aim was to study epidermis and the cellular structure of keratinocytes of psoriatic plaques and adjacent non‐lesional with healthy skin as a reference. Methods: Twelve patients with stable plaque psoriasis were studied and compared with a control group of eight healthy individuals. Fluorescein sodium was used as fluorophore. A hand held fibre‐optic laser scanner (Stratum®; Optiscan Pty., Melbourne, Australia) was used. The study included morphometric analyses. Results: The confocal in vivo images demonstrated characteristic features of epidermis and keratinocytes in lesional and non‐lesional skin vs. healthy skin. Morphometry based on FOCI demonstrated an approximately 30% increased width of keratinocytes of psoriatic skin vs. healthy control, and the number of keratinocytes per viewing field was reduced. FOCI allowed non‐invasive visualization of cell nuclei and parakeratosis of psoriatic epidermis. The horizontal width of dermal papillae of psoriatic skin was increased by approximately 50% as compared with healthy skin, and the flow of erythrocytes in the papillar vessels could be observed in real‐time. Conclusion: FOCI can directly visualize essential epidermal structures of plaque psoriasis in vivo, in real‐time and with cellular resolution without the need of taking biopsies and thus without disturbing the natural state of the skin. FOCI is a versatile future tool for non‐invasive microscopic diagnosis and therapy follow‐up of psoriasis.

Integrity signals

Registry

Crossref · 10.1111/j.1600-0846.2011.00585.x

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Portable confocal imaging can provide noninvasive assessment of lesional and nonlesional psoriatic skin.

    “Similarly, portable confocal imaging, which can provide noninvasive assessment of lesional and nonlesional psoriatic skin (182), is revolutionizing diagnosis and treatment of this disorder.”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Suihko, C., & Serup, J.
Affiliations
  • Linköping University (SE)
  • Bispebjerg Hospital (DK)
Corresponding author
Suihko, Christian
Venue
Skin Research and Technology
Publisher
Wiley
Published
2011-11-24
Volume
18
Issue
4
Pages
397-404
ISSN
  • 0909-752X (ISSN-L)
  • 1600-0846
OpenAlex
W2011563912
Cited by
4
References
8
Citations by year
2019: 1 · 2018: 1 · 2017: 1 · 2014: 1
FWCI
0.14
Type
journal article
Language
en
Open access
closed
Locations
  • Skin Research and Technology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Life Sciences › Immunology and Microbiology › Immunology › Psoriasis: Treatment and Pathogenesis
  • Health Sciences › Medicine › Dermatology › Dermatology and Skin Diseases
  • Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
Keywords
plaque psoriasis, in vivo skin imaging, keratinocyte morphology, epidermis, parakeratosis, dermal papilla, erythrocyte flow, non-invasive diagnosis, fluorescein, morphometrics
MeSH terms
Adult, Aged, Female, Fiber Optic Technology, Humans, Male, Microscopy, Fluorescence, Middle Aged, Psoriasis, Reference Values, Sensitivity and Specificity, Skin, Reproducibility of Results, Microscopy, Confocal, Equipment Failure Analysis, Dermoscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review