Challenges and Artifacts in Quantitative Photobleaching Experiments
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Confocal fluorescence recovery after photobleaching (FRAP) is today the prevalent tool when studying the diffusional and kinetic properties of proteins in living cells. Obtaining quantitative data for diffusion coefficients via FRAP, however, is challenged by the fact that both bleaching and scanning take a finite time. Starting from an experimental case, it is shown by means of computer simulations that this intrinsic temporal limitation can lead to a gross underestimation of diffusion coefficients. Determining the binding kinetics of proteins to membranes with FRAP is further shown to be severely hampered by additional diffusional contributions, e.g. diffusion‐limited binding. In some cases, the binding kinetics may even be masked entirely by diffusion. As current efforts to approach biological problems with biophysical models have to rely on experimentally determined model parameters, e.g. binding rates and diffusion constants, it is proposed that the accuracy in evaluating FRAP measurements can be improved by means of accompanying computer simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brownian motion in biological membranes
Saffman, P. G., & Delbrück, M. (1975) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.72.8.3111 · Cited by 1,773
Cited by
The fluorescent protein palette: tools for cellular imaging
Day, R. N., & Davidson, M. W. (2009) · Chemical Society Reviews · doi:10.1039/b901966a · Cited by 810
Simplified Equation to Extract Diffusion Coefficients from Confocal FRAP Data
Kang, M., Day, C. A., Kenworthy, A. K., & DiBenedetto, E. (2012) · Traffic · doi:10.1111/tra.12008 · Cited by 258
A Method Improving the Accuracy of Fluorescence Recovery after Photobleaching Analysis
Jönsson, P., Jonsson, M. P., Tegenfeldt, J. O., & Höök, F. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.134874 · Cited by 235
“The main shortcoming of these curvefitting approaches is that the bleaching profile must follow the function used for the curve fits throughout the recovery process (19).”
BackgroundA global view of protein expression in human cells, tissues, and organs
Pontén, F., Gry, M., Fagerberg, L., Lundberg, E., Asplund, A., Berglund, L., Oksvold, P., Björling, E., Hober, S., Kampf, C., et al. (2009) · Molecular Systems Biology · doi:10.1038/msb.2009.93 · Cited by 222
Mueller, F., Wach, P., & McNally, J. G. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.123182 · Cited by 166
“Although both original procedures presumed a uniform profile, in reality the profile is broadened for several reasons: the finite time for the photobleaching and imaging (27), the Gaussian intensity distribution of the bleaching laser beam (18,19), and fluorescence saturation (20).”
Background
Metadata
- Authors
- Weiss, M.
- Venue
- Traffic
- Publisher
- Wiley
- Published
- 2004-07-26
- Volume
- 5
- Issue
- 9
- Pages
- 662-671
- ISSN
- 1398-9219 (ISSN-L)
- 1600-0854
- OpenAlex
- W1526551292
- Cited by
- 127
- References
- 1
- FWCI
- 6.05
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.