Performance of Different Prediction Equations for Estimating Renal Function in Kidney Transplantation
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Numerous formulas have been developed to estimate renal function from biochemical, demographic and anthropometric data. Here we compared renal function derived from 12 published prediction equations with glomerular filtration rate (GFR) measurement by plasma iohexol clearance as reference method in a group of 81 renal transplant recipients enrolled in the Mycophenolate Mofetil Steroid Sparing (MY.S.S.) trial. Iohexol clearances and prediction equations were carried out in all patients at months 6, 9 and 21 after surgery. All equations showed a tendency toward GFR over-estimation: Walser and MDRD equations gave the best performance, however not more than 45% of estimated values were within +/-10% error. These formulas showed also the lowest bias and the highest precision: 0.5 and 9.2 mL/min/1.73 m2 (Walser), 2.7 and 10.4 mL/min/1.73 m2 (MDRD) in predicting GFR. A significantly higher rate of GFR decline ranging from -5.0 mL/min/1.73 m2/year (Walser) to -7.4 mL/min/1.73 m2/year (Davis-Chandler) was estimated by all the equations as compared with iohexol clearance (-3.0 mL/min/1.73 m2/year). The 12 prediction equations do not allow a rigorous assessment of renal function in kidney transplant recipients. In clinical trials of kidney transplantation, graft function should be preferably monitored using a reference method of GFR measurement, such as iohexol plasma clearance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
(1965) · The Lancet · doi:10.1016/s0140-6736(65)91037-8 · Cited by 16,856
Prediction of Creatinine Clearance from Serum Creatinine
Cockcroft, D. W., & Gault, H. (1976) · Nephron · doi:10.1159/000180580 · Cited by 15,309
Levey, A. S., Coresh, J., Bolton, K., Culleton, B. F., Harvey, K. S., Ikizler, T. A., Johnson, C. A., Kausz, A., Kimmel, P. L., Kusek, J. W., et al. (2002) · University of Groningen research database (University of Groningen / Centre for Information Technology) · Cited by 11,633
(2000) · Journal of the American Society of Nephrology · Cited by 1,718
Some suggestions for measuring predictive performance
Sheiner, L. B., & Beal, S. L. (1981) · Journal of Pharmacokinetics and Biopharmaceutics · doi:10.1007/bf01060893 · Cited by 1,617 · cited 1×
“For both bias and precision, the smaller these quantities are, the greater is the performance of the GFR prediction model (29).”
BackgroundA Simple Method for the Determination of Glomerular Filtration Rate
Bröchner-Mortensen, J. (1972) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365517209084290 · Cited by 886 · cited 2×
“According to Bröchner-Mortensen (13), the plasma clearance was then estimated by the formula: CL = (0.990778 × CL1) − (0.001218 × CL21) Blood samples were analyzed for creatinine (modified rate Jaffé method, coefficient of variation 3.70”
MethodInfluentialReport of the committee on the genetic constitution of autosomes other than chromosomes 1, 2, and 6
Ruddle, F. H., & Meera Khan, P. (1976) · Cytogenetic and Genome Research · doi:10.1159/000130554 · Cited by 845
Creatinine Clearance: Bedside Estimate
JELLIFFE, R. W. (1973) · Annals of Internal Medicine · doi:10.7326/0003-4819-79-4-604 · Cited by 489
Lin, J., Knight, E. L., Hogan, M. L., & Singh, A. K. (2003) · Journal of the American Society of Nephrology · doi:10.1097/01.asn.0000088721.98173.4b · Cited by 413 · cited 1×
“This conclusion is in agreement with recent studies in nontransplant child and adult patients (33), in adult without kidney disease (34), as well as very recently in transplant recipients (12) showing great inaccuracies of various formulas in predicting GFR values.”
ResultPlasma clearance of nonradioactive iohexol as a measure of glomerular filtration rate.
Gaspari, F., Perico, N., Ruggenenti, P., Mosconi, L., Amuchastegui, C. S., Guerini, E., Daina, E., & Remuzzi, G. (1995) · Journal of the American Society of Nephrology · doi:10.1681/asn.v62257 · Cited by 375
Self-citationKrutzén, E., Bäck, S. E., Nilsson-Ehle, I., & Nilsson‐Ehle, P. (1984) · PubMed · Cited by 319
PREDICTING GLOMERULAR FILTRATION RATE AFTER KIDNEY TRANSPLANTATION
Nankivell, B. J., Gruenewald, S. M., Allen, R. D. M., & Chapman, J. R. (1995) · Transplantation · doi:10.1097/00007890-199506270-00007 · Cited by 292 · cited 2×
“However, our data and other recent observations (11,17,32) challenge this current view of”
MethodResultUse of Serum Creatinine Concentrations to Determine Renal Function1
Bjornsson, T. D. (1979) · Clinical Pharmacokinetics · doi:10.2165/00003088-197904030-00003 · Cited by 276
Renal Inulin Clearance versus Total Plasma Clearance of51Cr-EDTA
Bröchner-mortensen, J., Giese, J., & Rossing, N. (1969) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365516909081695 · Cited by 223
Pierrat, A., Gravier, E., Saunders, C., Caira, M.-V., Aït-Djafer, Z., Legras, B., & Mallié, J.-P. (2003) · Kidney International · doi:10.1046/j.1523-1755.2003.00208.x · Cited by 174 · cited 1×
“This conclusion is in agreement with recent studies in nontransplant child and adult patients (33), in adult without kidney disease (34), as well as very recently in transplant recipients (12) showing great inaccuracies of various formulas in predicting GFR values.”
ResultPrecision of plasma clearance of iohexol for estimation of GFR in patients with renal disease.
Gaspari, F., Perico, N., Matalone, M., Signorini, O., Azzollini, N., Mister, M., & Remuzzi, G. (1998) · Journal of the American Society of Nephrology · doi:10.1681/asn.v92310 · Cited by 161
Self-citationIsraelit, A. H., Long, D. L., White, M. G., & Hull, A. R. (1973) · Kidney International · doi:10.1038/ki.1973.127 · Cited by 159
ESTIMATION OF CREATININE CLEARANCE WHEN URINE CANNOT BE COLLECTED
Jelliffe, R. W. (1971) · The Lancet · doi:10.1016/s0140-6736(71)91484-x · Cited by 144
Mariat, C., Alamartine, É., Barthélemy, J., de Filippis, J. P., Thibaudin, D., Berthoux, P., Laurent, B., Thibaudin, L., & Berthoux, F. C. (2003) · Kidney International · doi:10.1111/j.1523-1755.2004.00350.x · Cited by 126 · cited 2×
“Together, they are tools for assessing renal function (12,14,15), here generally referred as tests predicting GFR.”
MethodResultGates, G. F. (1985) · American Journal of Kidney Diseases · doi:10.1016/s0272-6386(85)80051-2 · Cited by 89
ARGINASE RELEASE FOLLOWING LIVER REPERFUSION EVIDENCE OF HEMODYNAMIC ACTION OF ARGINASE INFUSIONS
LÄNGLE, F., ROTH, E., Steininger, R., WINKLER, S., & Mühlbacher, F. (1995) · Transplantation · doi:10.1097/00007890-199506000-00007 · Cited by 89
Walser, M., Drew, H. H., & Guldan, J. L. (1993) · Kidney International · doi:10.1038/ki.1993.361 · Cited by 85
Stoves, J. L., Lindley, E. J., Barnfield, M. C., Burniston, M. T., & Newstead, C. G. (2002) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/17.11.2036 · Cited by 65 · cited 1×
“However, our data and other recent observations (11,17,32) challenge this current view of”
ResultThe reliability of different formulae to predict creatinine clearance
Verhave, J. C., Baljé-Volkers, C. P., Hillege, H. L., de Zeeuw, D., & de Jong, P. E. (2003) · Journal of Internal Medicine · doi:10.1046/j.1365-2796.2003.01141.x · Cited by 57 · cited 2×
“Together, they are tools for assessing renal function (12,14,15), here generally referred as tests predicting GFR.”
MethodA practical method to statistically classify devices according to their relative accuracy
Minini, P., Gaspoz, J., Pichot, V., Costes, F., Roche, F., Lacour, J. R., Antoniadis, A., & Barthélemy, J. (2001) · Clinical Physiology · doi:10.1046/j.1365-2281.2001.00320.x · Cited by 3
Cited by
Levey, A. S., Coresh, J., Greene, T., Stevens, L. A., Zhang, Y. (., Hendriksen, S., Kusek, J. W., & Van Lente, F. (2006) · Annals of Internal Medicine · doi:10.7326/0003-4819-145-4-200608150-00004 · Cited by 5,725
Assessing Kidney Function — Measured and Estimated Glomerular Filtration Rate
Stevens, L. A., Coresh, J., Greene, T., & Levey, A. S. (2006) · New England Journal of Medicine · doi:10.1056/nejmra054415 · Cited by 2,952
Levey, A. S., Coresh, J., Greene, T., Marsh, J., Stevens, L. A., Kusek, J. W., Van Lente, F., & for Chronic Kidney Disease Epidemiology Collaboration (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.077180 · Cited by 1,855
Costimulation Blockade with Belatacept in Renal Transplantation
Vincenti, F., Larsen, C., Durrbach, A., Wekerle, T., Nashan, B., Blancho, G., Lang, P., Grinyo, J., Halloran, P. F., Solez, K., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa050085 · Cited by 861
Evaluation of the Modification of Diet in Renal Disease Study Equation in a Large Diverse Population
Stevens, L. A., Coresh, J., Feldman, H. I., Greene, T., Lash, J. P., Nelson, R. G., Rahman, M., Deysher, A. E., Zhang, Y. (., Schmid, C. H., et al. (2007) · Journal of the American Society of Nephrology · doi:10.1681/asn.2007020199 · Cited by 574
Metadata
- Authors
- Gaspari, F., Ferrari, S., Stucchi, N., Centemeri, E., Carrara, F., Pellegrino, M., Gherardi, G., Gotti, E., Segoloni, G., Salvadori, M., Rigotti, P., Valente, U., Donati, D., Sandrini, S., Sparacino, V., Remuzzi, G., & Perico, N.
- Venue
- American Journal of Transplantation
- Publisher
- Elsevier BV
- Published
- 2004-11
- Volume
- 4
- Issue
- 11
- Pages
- 1826-1835
- ISSN
- 1600-6135 (ISSN-L)
- OpenAlex
- W2065749193
- Cited by
- 192
- References
- 26
- FWCI
- 13.27
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.