The DOI matches its Crossref record.
Clinical Operational Tolerance after Kidney Transplantation
Open accessAbstract
Induction of allograft-specific tolerance and the detection of a "tolerance" state in recipients under immunosuppression with long-term stable graft function are major challenges in transplantation. Clinical "operational tolerance," defined as stable and acceptable graft function without immunosuppression for years, is a rare event. There is no report on the clinical history of such patients. In this article, we report on the medical history of 10 kidney recipients who display an immunosuppressive drug-free "operational tolerance" for 9.4 +/- 5.2 years. Clinical factors that may favor such a tolerant state are underlined. Firstly, most of the patients interrupted immunosuppression over a long time period (until 4 years), which mimics the procedure of intentional immunosuppression weaning following liver transplantation. Secondly, donor age was younger (median 25 years) than the one of the general transplanted population, suggesting that graft quality is one of the conditions favoring "operational tolerance." Moreover, the "operationally tolerant" recipients may be 'low responders' to blood transfusions (PRA 6 +/- 5.4%, six blood transfusions). We also show that "operational tolerance" occurs in the presence of anti-donor class II antibodies, as assessed in two patients. Finally, two patients degraded their renal function 9 to 13 years after treatment withdrawal, however only one presented histological lesions of chronic rejection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Identification of a B cell signature associated with renal transplant tolerance in humans
Newell, K. A., Asare, A., Kirk, A. D., Gisler, T. D., Bourcier, K., Suthanthiran, M., Burlingham, W. J., Marks, W. H., Sanz, I., Lechler, R. I., et al. (2010) · Journal of Clinical Investigation · doi:10.1172/jci39933 · Cited by 678
Development of a cross-platform biomarker signature to detect renal transplant tolerance in humans
Sagoo, P., Perucha, E., Sawitzki, B., Tomiuk, S., Stephens, D. A., Miqueu, P., Chapman, S., Craciun, L., Sergeant, R., Brouard, S., et al. (2010) · Journal of Clinical Investigation · doi:10.1172/jci39922 · Cited by 528
Self-citationPallier, A., Hillion, S., Danger, R., Giral, M., Racapé, M., Degauque, N., Dugast, E., Ashton-Chess, J., Pettré, S., Lozano, J. J., et al. (2010) · Kidney International · doi:10.1038/ki.2010.162 · Cited by 282
Self-citationArtificial Intelligence: Present and Future Potential for Solid Organ Transplantation
Peloso, A., Moeckli, B., Delaune, V., Oldani, G., Andres, A., & Compagnon, P. (2022) · Transplant International · doi:10.3389/ti.2022.10640 · Cited by 67
Metadata
- Authors
- Roussey-Kesler, G., Giral, M., Moreau, A., Subra, J.-F., Legendre, C., Noël, C., Pillebout, E., Brouard, S., & Soulillou, J.-P.
- Venue
- American Journal of Transplantation
- Publisher
- Elsevier BV
- Published
- 2006-04
- Volume
- 6
- Issue
- 4
- Pages
- 736-746
- ISSN
- 1600-6135 (ISSN-L)
- OpenAlex
- W2039239630
- Cited by
- 193
- References
- 0
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Clinical Operational Tolerance after Kidney Transplantation. https://app.cochat.ai/papers/10.1111/j.1600-6143.2006.01280.x
- The paper
- Roussey-Kesler, G., Giral, M., Moreau, A., Subra, J.-F., Legendre, C., Noël, C., Pillebout, E., Brouard, S., & Soulillou, J.-P. (2006). Clinical Operational Tolerance after Kidney Transplantation. American Journal of Transplantation. https://doi.org/10.1111/j.1600-6143.2006.01280.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.