Clinical Magnetic Resonance Imaging of Pancreatic Islet Grafts After Iron Nanoparticle Labeling
Open accessThe DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
There is a crucial need for noninvasive assessment tools after cell transplantation. This study investigates whether a magnetic resonance imaging (MRI) strategy could be clinically applied to islet transplantation. The purest fractions of seven human islet preparations were labeled with superparamagnetic iron oxide particles (SPIO, 280 microg/mL) and transplanted into four patients with type 1 diabetes. MRI studies (T2*) were performed prior to and at various time points after transplantation. Viability and in vitro and in vivo functions of labeled islets were similar to those of control islets. All patients could stop insulin after transplantation. The first patient had diffuse hypointense images on her baseline liver MRI, typical for spontaneous high iron content, and transplant-related modifications could not be observed. The other three patients had normal intensity on pretransplant images, and iron-loaded islets could be identified after transplantation as hypointense spots within the liver. In one of them, i.v. iron therapy prevented subsequent visualization of the spots because of diffuse hypointense liver background. Altogether, this study demonstrates the feasibility and safety of MRI-based islet graft monitoring in clinical practice. Iron overload (spontaneous or induced) represents the major obstacle to the technique.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
International trial of the Edmonton protocol for islet transplantation
Shapiro, A. M. J., Ricordi, C., Hering, B. J., Auchincloss, H., Lindblad, R., Robertson, R. P., Secchi, A., Brendel, M. D., Berney, T., Brennan, D. C., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061267 · Cited by 1,942
Self-citationFive-Year Follow-Up After Clinical Islet Transplantation
Ryan, E. A., Paty, B. W., Senior, P. A., Bigam, D., Alfadhli, E., Kneteman, N. M., Lakey, J. R. T., & Shapiro, A. M. J. (2005) · Diabetes · doi:10.2337/diabetes.54.7.2060 · Cited by 1,641 · cited 1×
“Unfortunately, outcomes of 80% insulin independence at 1 year have not been sustained (1–3), and the latest updates report insulin independence rates of approximately 10–15% at 5 years, although graft function (C-peptide positivity) was retained in a vast majority of patients (4).”
BackgroundSelf-citationNon-invasive assessment of hepatic iron stores by MRI
Gandon, Y., Olivié, D., Guyader, D., Aubé, C., Oberti, F., Sebille, V, & Deugnier, Y. (2004) · The Lancet · doi:10.1016/s0140-6736(04)15436-6 · Cited by 671
Arbab, A. S., Bashaw, L. A., Miller, B. R., Jordan, E. K., Lewis, B. K., Kalish, H., & Frank, J. A. (2003) · Radiology · doi:10.1148/radiol.2293021215 · Cited by 552
In vivo detection of single cells by MRI
Shapiro, E. M., Sharer, K., Skrtic, S., & Koretsky, A. P. (2006) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20718 · Cited by 378
In vivo imaging of islet transplantation
Evgenov, N. V., Medarova, Z., Dai, G., Bonner-Weir, S., & Moore, A. (2006) · Nature Medicine · doi:10.1038/nm1316 · Cited by 249
Visualization of Early Engraftment in Clinical Islet Transplantation by Positron-Emission Tomography
Eich, T., Eriksson, O., & Lundgren, T. (2007) · New England Journal of Medicine · doi:10.1056/nejmc070201 · Cited by 198
MRI of transplanted pancreatic islets
Jirák, D., Kríz, J., Herynek, V., Andersson, B., Girman, P., Burian, M., Saudek, F., & Hájek, M. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20282 · Cited by 169
Self-citationIn Vivo Imaging of Immune Rejection in Transplanted Pancreatic Islets
Evgenov, N. V., Medarova, Z., Pratt, J., Pantazopoulos, P., Leyting, S., Bonner-Weir, S., & Moore, A. (2006) · Diabetes · doi:10.2337/db06-0484 · Cited by 160
Imaging Islets Labeled With Magnetic Nanoparticles at 1.5 Tesla
Tai, J. H., Foster, P. J., Hernandez, A. L. R., Feng, B., Hasilo, C. P., Martinez, V., Ramadan, S. S., Snir, J. A., Melling, C. W. J., Dhanvantari, S., et al. (2006) · Diabetes · doi:10.2337/db06-0393 · Cited by 155
Toso, C., Kessler, L., Penfornis, A., Bayle, F., Thivolet, C. H., Morel, P., Ris, F., Benhamou, P., Oberholzer, J., Colin, C., et al. (2001) · Diabetologia · doi:10.1007/s001250100571 · Cited by 121
Self-citationSystematic screening of potential β-cell imaging agents
Sweet, I. R., Cook, D. L., Lernmark, Å., Greenbaum, C. J., Wallen, A. R., Marcum, E. S., Stekhova, S. A., & Krohn, K. A. (2004) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2003.12.182 · Cited by 107
Magnetic Resonance Imaging of Pancreatic Islets in Tolerance and Rejection
Kříž, J., Jirák, D., Girman, P., Berková, Z., Zacharovová, K., Honsová, E., Lodererová, A., Hájek, M., & Saudek, F. (2005) · Transplantation · doi:10.1097/01.tp.0000183959.73681.b9 · Cited by 97
Self-citationPositron-Emission Tomography Imaging of Early Events after Transplantation of Islets of Langerhans
Toso, C., Zaidi, H., Morel, P., Armanet, M., Andrès, A., Pernin, N., Baertschiger, R. M., Slosman, D. O., Bühler, L. H., Bosco, D., et al. (2005) · Transplantation · doi:10.1097/01.tp.0000149501.50870.9d · Cited by 92
Self-citationBriley-Saebo, K. C., Johansson, L. O., Hustvedt, S. O., Haldorsen, A. G., Bj??rnerud, A., Fayad, Z. A., & Ahlstrom, H. K. (2006) · Investigative Radiology · doi:10.1097/01.rli.0000221321.90261.09 · Cited by 88
Toso, C., Baertschiger, R. M., Morel, P., Bosco, D., Armanet, M., Wojtusciszyn, A., Badet, L., Philippé, J., Becker, C. D., Hadaya, K., et al. (2006) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2006.01303.x · Cited by 83
Self-citationKalber, T. L., Smith, C. J., Howe, F. A., Griffiths, J. R., Ryan, A. J., Waterton, J. C., & Robinson, S. P. (2005) · Investigative Radiology · doi:10.1097/01.rli.0000188025.66872.e4 · Cited by 34
Cited by
Reddy, L. H., Arias, J. L., Nicolas, J., & Couvreur, P. (2012) · Chemical Reviews · doi:10.1021/cr300068p · Cited by 2,010
Chemistry of MRI Contrast Agents: Current Challenges and New Frontiers
Wahsner, J., Gale, E. M., Rodríguez-Rodríguez, A., & Caravan, P. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00363 · Cited by 1,603
Biological applications of magnetic nanoparticles
Colombo, M., Carregal-Romero, S., Casula, M. F., Gutiérrez, L., Morales, M. P., Böhm, I. B., Heverhagen, J. T., Prosperi, D., & Parak, W. J. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15337h · Cited by 1,315
Karussis, D., Karageorgiou, C., Vaknin-Dembinsky, A., Gowda-Kurkalli, B., Gomori, J. M., Kassis, I., Bulte, J. W. M., Petrou, P., Ben-Hur, T., Abramsky, O., et al. (2010) · Archives of Neurology · doi:10.1001/archneurol.2010.248 · Cited by 941
Assessing the In Vitro and In Vivo Toxicity of Superparamagnetic Iron Oxide Nanoparticles
Mahmoudi, M., Hofmann, H., Rothen-Rutishauser, B., & Petri-Fink, A. (2012) · Chemical Reviews · doi:10.1021/cr2002596 · Cited by 617
Metadata
- Authors
- Toso, C., Vallee, J.-P., Morel, P., Ris, F., Demuylder-Mischler, S., Lepetit-Coiffe, M., Marangon, N., Saudek, F., James Shapiro, A. M., Bosco, D., & Berney, T.
- Venue
- American Journal of Transplantation
- Publisher
- Elsevier BV
- Published
- 2008-03
- Volume
- 8
- Issue
- 3
- Pages
- 701-706
- ISSN
- 1600-6135 (ISSN-L)
- OpenAlex
- W2135540789
- Cited by
- 263
- References
- 17
- FWCI
- 31.03
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.