Clinical Ex Vivo Lung Perfusion—Pushing the Limits
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
Ex vivo lung perfusion (EVLP) provides the ability to evaluate donor lungs before transplantation. Yet, limited prospective clinical data exist with regard to its potential to recondition unacceptable donor lungs. This paper summarizes the results of a prospective study of lung transplantation using only initially unacceptable donor lungs, which were improved by EVLP for 2-4 h. From March 2010-June 2011, 13 lungs were evaluated ex vivo. Median donor PaO(2) at FiO(2) 1.0/PEEP5 was 216 mmHg (range 133-271). Four lungs, all with trauma history, showed no improvement and were discarded. Nine lungs improved to a ΔPO(2) higher than 350 mmHg. Median PvO(2) at final assessment in these lungs was 466 mmHg (range 434-525). These lungs were transplanted with a median total ischemic time of 577 min (range 486-678). None of the patients developed primary graft dysfunction grades 2 or 3 within 72 h after transplantation. One patient with secondary pulmonary hypertension was left on a planned prolonged extracorporeal membrane oxygenation postoperatively. Median intubation time was 2 days. Thirty-day mortality was 0%. During the observation period, 119 patients received standard lung transplantation with comparable perioperative outcome. EVLP has a significant potential to improve the quality of otherwise unacceptable donor lungs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Normothermic Ex Vivo Lung Perfusion in Clinical Lung Transplantation
Cypel, M., Yeung, J. C., Liu, M., Anraku, M., Chen, F., Karolak, W., Sato, M., Laratta, J., Azad, S., Madonik, M., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1014597 · Cited by 1,106 · cited 2×
“In a report on 20 patients, they used donor lungs with a median PaO2/FiO2 ratio of 335 mmHg (7), a value that is clearly above the current lower limit for the acceptance of donor lungs, which is 300 mmHg.”
MethodOrgan Donation and Utilization in the United States, 1996–2005
Punch, J. D., Hayes, D. H., LaPorte, F. B., McBride, V., & Seely, M. S. (2007) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2007.01779.x · Cited by 600 · cited 1×
“As a consequence of that, lungs are currently used in only 15% of all reported donors (3,4).”
BackgroundLiver Transplantation in the United States, 1999-2008
Thuluvath, P. J., Guidinger, M. K., Fung, J. J., Johnson, L. B., Rayhill, S. C., & Pelletier, S. J. (2010) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2010.03037.x · Cited by 574
Technique for Prolonged Normothermic Ex Vivo Lung Perfusion
Cypel, M., Yeung, J. C., Hirayama, S., Rubacha, M., Fischer, S., Anraku, M., Sato, M., Harwood, S., Pierre, A., Waddell, T. K., et al. (2008) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2008.09.003 · Cited by 537 · cited 2×
“That such prolonged periods of EVLP are possible is suggested by current experimental work, which shows that lungs remain stable on the EVLP system up to 12 h using acellular perfusion (8).”
MethodCypel, M., Rubacha, M., Yeung, J., Hirayama, S., Torbicki, K., Madonik, M., Fischer, S., Hwang, D., Pierre, A., Waddell, T. K., et al. (2009) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2009.02775.x · Cited by 270 · cited 1×
“A combination of other physiological parameters such as compliance, peak airway pressures and pulmonary vascular resistance has been described as crucial to obtain a full picture of the functional capacity of the lung (16).”
BackgroundInstitutional experience with extracorporeal membrane oxygenation in lung transplantation☆
Aigner, C., Wisser, W., Taghavi, S., Lang, G., Jaksch, P., Czyzewski, D., & Klepetko, W. (2007) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2006.11.049 · Cited by 238 · cited 1×
“In the patient with secondary pulmonary hypertension, ECMO was prolonged postoperatively according to our standard treatment concept of transplantation of patients with pulmonary hypertension (10,11).”
MethodSelf-citationRisk factors for primary graft dysfunction after lung transplantation
Whitson, B. A., Nath, D. S., Johnson, A. C., Walker, A. R., Prekker, M. E., Radosevich, D. M., Herrington, C. S., & Dahlberg, P. S. (2006) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.08.039 · Cited by 185 · cited 1×
“However, it has also been shown that the initial function of the transplanted lung significantly influences perioperative and long-term outcome and that marginal donor organs may compromise recipient outcome, especially when used for high-risk recipients (14,15).”
BackgroundLung Transplantation in the United States, 1999-2008
Yusen, R. D., Shearon, T. H., Qian, Y., Kotloff, R., Barr, M. L., Sweet, S., Dyke, D. B., & Murray, S. (2010) · American Journal of Transplantation · doi:10.1111/j.1600-6143.2010.03055.x · Cited by 151
Pereszlenyi, A. (2002) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/s1010-7940(02)00058-1 · Cited by 145 · cited 1×
“In the patient with secondary pulmonary hypertension, ECMO was prolonged postoperatively according to our standard treatment concept of transplantation of patients with pulmonary hypertension (10,11).”
MethodBharat, A., Narayanan, K., Street, T., Fields, R. C., Steward, N. S., Aloush, A. A., Meyers, B., Schuessler, R. B., Trulock, E. P., Patterson, G. A., et al. (2007) · Transplantation · doi:10.1097/01.tp.0000250579.08042.b6 · Cited by 135 · cited 1×
“However, it has also been shown that the initial function of the transplanted lung significantly influences perioperative and long-term outcome and that marginal donor organs may compromise recipient outcome, especially when used for high-risk recipients (14,15).”
BackgroundExtended donor criteria in lung transplantation: Impact on organ allocation
Botha, P., Trivedi, D., Weir, C. J., Searl, C. P., Corris, P. A., Dark, J. H., & Schueler, S. V. B. (2006) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2005.12.037 · Cited by 121 · cited 1×
“However, there is evidence suggesting an increased incidence of primary graft dysfunction (PGD) in recipients of such marginal organs (6).”
BackgroundKinetics of lactate metabolism during acellular normothermic ex vivo lung perfusion
Koike, T., Yeung, J. C., Cypel, M., Rubacha, M., Matsuda, Y., Sato, M., Waddell, T. K., Liu, M., & Keshavjee, S. H. (2011) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2011.07.014 · Cited by 90
Smits, J. M., Nossent, G. D., de Vries, E., Rahmel, A. O., Meiser, B., Strueber, M., & Gottlieb, J. (2010) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2010.08.006 · Cited by 59 · cited 1×
“However, the demand for donor lungs exceeds the number of available organs by far, resulting in substantial waiting list mortality (1,2).”
Background
Cited by
Normothermic Ex Vivo Lung Perfusion in Clinical Lung Transplantation
Cypel, M., Yeung, J. C., Liu, M., Anraku, M., Chen, F., Karolak, W., Sato, M., Laratta, J., Azad, S., Madonik, M., et al. (2011) · New England Journal of Medicine · doi:10.1056/nejmoa1014597 · Cited by 1,106
Meyer, K. C., Raghu, G., Verleden, G. M., Corris, P. A., Aurora, P., Wilson, K. C., Brozek, J., Glanville, A. R., & the ISHLT/ATS/ERS BOS Task Force Committee (2014) · European Respiratory Journal · doi:10.1183/09031936.00107514 · Cited by 555
Hoetzenecker, K., Schwarz, S., Muckenhuber, M., Benazzo, A., Frommlet, F., Schweiger, T., Bata, O., Jaksch, P., Ahmadi, N., Muraközy, G., et al. (2018) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2017.10.144 · Cited by 242
“Cystic fibrosis 13 (11) 89 (26) 15 (12)”
Self-citationHoetzenecker, K., Benazzo, A., Stork, T., Sinn, K., Schwarz, S., Schweiger, T., Klepetko, W., Kifjak, D., Baron, D. M., Hager, H., et al. (2020) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2019.10.155 · Cited by 157
Self-citationVan Raemdonck, D., Hartwig, M. G., Hertz, M. I., Davis, R. D., Cypel, M., Hayes, D., Ivulich, S., Kukreja, J., Lease, E. D., Loor, G., et al. (2017) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2017.07.013 · Cited by 128
Metadata
- Authors
- Aigner, C., Slama, A., Hötzenecker, K., Scheed, A., Urbanek, B., Schmid, W., Nierscher, F. J., Lang, G., & Klepetko, W.
- Venue
- American Journal of Transplantation
- Publisher
- Elsevier BV
- Published
- 2012-07
- Volume
- 12
- Issue
- 7
- Pages
- 1839-1847
- ISSN
- 1600-6135 (ISSN-L)
- OpenAlex
- W1561436010
- Cited by
- 176
- References
- 13
- FWCI
- 21.05
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.