Objective Intraoperative extracorporeal membrane oxygenation (ECMO) is usually reserved to support patients during complex lung transplantation. We hypothesized that a routine application of intraoperative ECMO in all patients improves primary graft function.Methods Patients receiving a bilateral lung transplantation between November 2016 and July 2018 at the Medical University of Vienna were included in this prospective, single-center observational study. All transplantations were uniformly performed on central venoarterial ECMO support, with the possibility to extend ECMO into the early postoperative period whenever graft function did not meet established quality criteria at the end of implantation. Primary graft dysfunction (PGD) grades were evaluated at 24, 48, and 72 hours after transplantation. Perioperative complications and survival outcome were assessed.Results A total of 159 patients were included in the study. At 24 hours post-transplantation, 38.4% (n = 61) of patients were already extubated, 48.4% (n = 77) were classified as PGD0, 4.4% (n = 7) as PGD1, 3.1% (n = 5) as PGD2, 2.5% (n = 4) as PGD3, and 3.1% (n = 5) were "ungradable" due to prophylactic postoperative prolongation of ECMO. At 72 hours after transplantation, 76.7% (n = 122) of the patients were extubated, as opposed to only 1.3% (n = 2) of patients classified as PGD3. The median time of mechanical ventilation was 29 hours (interquartile range, 17-58). The 90-day-mortality was 3.1%, and 2-year survival was 86%.Conclusions Routine use of intraoperative ECMO resulted in excellent primary graft function and mid-term outcome in patients undergoing lung transplantation. To the best of our knowledge, the herein measured PGD rates are the lowest reported in the literature to date. Our results advocate a routine intraoperative use of ECMO in bilateral lung transplantation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jtcvs.2019.10.155

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Metadata

Authors
Hoetzenecker, K., Benazzo, A., Stork, T., Sinn, K., Schwarz, S., Schweiger, T., Klepetko, W., Kifjak, D., Baron, D. M., Hager, H., Faybik, P., Bacher, A., Krenn, C., & Prosch, H.
Affiliations
Medical University of Vienna (AT)
Venue
The Journal of Thoracic and Cardiovascular Surgery
Publisher
Elsevier BV
Published
2020-07
Volume
160
Issue
1
Pages
320-327.e1
ISSN
0022-5223 (ISSN-L)
OpenAlex
W2991415107
Cited by
157
References
32
Citations by year
2026: 13 · 2025: 20 · 2024: 23 · 2023: 23 · 2022: 33 · 2021: 25 · 2020: 18
FWCI
18.61
Type
journal article
Language
en
Open access
Locations
  • Journal of Thoracic and Cardiovascular Surgery (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Transplantation: Methods and Outcomes
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Mechanical Circulatory Support Devices
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Respiratory Support and Mechanisms
Keywords
bilateral lung transplantation, primary graft dysfunction, primary graft function, extubation, mechanical ventilation duration, postoperative survival, perioperative complications
MeSH terms
Adult, Female, Humans, Male, Middle Aged, Postoperative Complications, Prospective Studies, Tissue Donors, Extracorporeal Membrane Oxygenation, Lung Transplantation, Primary Graft Dysfunction, Transplant Recipients

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review