CoChat

METABOLIC EVENTS IN INFANTS OF DIABETIC MOTHERS DURING FIRST 24 HOURS AFTER BIRTH I.: Changes in Plasma Glucose, Insulin and Glucagon

KÜHL, CLAUS, ANDERSEN, G. E., HERTEL, J., MØLSTED‐PEDERSEN, L. · 1982 · Acta Paediatrica
Cited by 46

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

Changes in plasma glucose, nonantibody‐bound insulin and glucagon concentrations were studied in 32 newborn infants of diabetic mothers (IDM) during the first 24 hours after birth. Ten infants were born to White class A mothers and 22 to class B‐F mothers. The infants were kept fasting during the investigative period and blood was sampled from an umbilical artery catheter. At birth, plasma glucose and glucagon levels were similar in the class A and B‐F infants, whereas nonantibody‐bound insulin levels were approximately 15‐fold higher in the class B‐F infants than in the class A infants (p<0.001). After birth, plasma glucose fell in all infants, the nadir being reached at two hours (p<0.01). Plasma glucose fell by approximately 35 % in the class A infants and 63 % in the class B‐F infants (p<0.01). Eight IDM had asymptomatic hypoglycemia (plasma glucose <1.9 mmol/l) and four of these infants had glucose levels below 1.7 mmol/l and were withdrawn from further study. In the remaining four hypoglycemic IDM, plasma glucose was about 1.6‐fold higher (p<0.01) and insulin about 11‐fold higher (p<0.001) at birth compared to the 24 normoglycemic IDM. The hypoglycemia was attended by unchanged insulin levels in the class A infants, whereas insulin fell in the class B‐F infant (p<0.01). However, during the whole investigative period, plasma insulin of the class B‐F infants was higher than that of the class A infants (p<0.01). After birth, plasma glucagon increased slowly in all IDM and peak values were reached after 12 hours in the class A infants (p<0.05) and 24 hours in the class B‐F infants (p<0.01). Only those infants who became hypoglycemic after birth exhibited a significant increment in plasma glucagon from 0‐2 hours (p<0.05). These results suggest that neonatal hypoglycemia of IDM results from high plasma levels of nonantibody‐bound insulin together with a very retarded increment in plasma glucagon levels. The degree of neonatal hypoglycemia and hyperinsulinemia of an individual IDM seems to be positively correlated to the severity of the diabetes of the mother.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1651-2227.1982.tb09366.x

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 46

Metadata

Authors
KÜHL, C., ANDERSEN, G. E., HERTEL, J., & MØLSTED‐PEDERSEN, L.
Venue
Acta Paediatrica
Publisher
Wiley
Published
1982-01
Volume
71
Issue
1
Pages
19-25
ISSN
  • 0365-1436 (ISSN-L)
  • 0803-5253
  • 1651-2227
OpenAlex
W2978004646
Cited by
46
References
1
FWCI
5.10
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: METABOLIC EVENTS IN INFANTS OF DIABETIC MOTHERS DURING FIRST 24 HOURS AFTER BIRTH I.: Changes in Plasma Glucose, Insulin and Glucagon. https://app.cochat.ai/papers/10.1111/j.1651-2227.1982.tb09366.x
The paper
KÜHL, C., ANDERSEN, G. E., HERTEL, J., & MØLSTED‐PEDERSEN, L. (1982). METABOLIC EVENTS IN INFANTS OF DIABETIC MOTHERS DURING FIRST 24 HOURS AFTER BIRTH I.: Changes in Plasma Glucose, Insulin and Glucagon. Acta Paediatrica. https://doi.org/10.1111/j.1651-2227.1982.tb09366.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.