The DOI matches its Crossref record.
Influence of Implant Length and Bicortical Anchorage on Implant Stress Distribution
Abstract
Background: Short implants present superior failure rates for everybody. Purpose: The aim of this theoretic study was to assess to what extent implant length and bicortical anchorage affect the way stress is transferred to implant components, the implant proper, and the surrounding bone. Materials and Methods: Stress analysis was performed using finite element analysis. A three‐dimensional linear elastic model was generated. All implants modeled were of the same diameter (3.75 mm) but varied in length, at 6, 7, 8, 9, 10, 11, and 12 mm (Branemark System®, Nobel Biocare AB, Gothenburg, Sweden). Each implant was modeled with a titanium abutment screw and abutment, a gold cylinder and prosthetic screw, and a ceramic crown. The implants were seated in a supporting bone structure consisting of cortical and cancellous bone. An occlusal load of 100 N was applied at a 30° angle to the buccolingual plane. Results: With the selected model and bone properties, the coronal cortical anchorage was dominating, and the bone stress concentrated to that area. Conclusions: The maximum bone stress was virtually constant, independent of implant length and bicortical anchorage. The maximum implant stress, however, increased somewhat with implant length and bicortical anchorage.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Application of the finite element method in dental implant research
Van Staden, R. C., Guan, H., & Loo, Y. C. (2006) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/10255840600837074 · Cited by 298
Lemos, C. A. A., Ferro-Alves, M. L., Okamoto, R., Mendonça, M. R., & Pellizzer, E. P. (2016) · Journal of Dentistry · doi:10.1016/j.jdent.2016.01.005 · Cited by 261
Naguib, G. H., Hashem, A. B. H., Natto, Z. S., Abougazia, A. O., Mously, H. A., & Hamed, M. T. (2023) · Journal of Oral Implantology · doi:10.1563/aaid-joi-d-21-00023 · Cited by 15
Metadata
- Authors
- Pierrisnard, L., Renouard, F., Renault, P., & Barquins, M.
- Venue
- Clinical Implant Dentistry and Related Research
- Publisher
- Wiley
- Published
- 2003-12
- Volume
- 5
- Issue
- 4
- Pages
- 254-262
- ISSN
- 1523-0899 (ISSN-L)
- 1708-8208
- OpenAlex
- W2066180657
- Cited by
- 220
- References
- 0
- FWCI
- 2.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Influence of Implant Length and Bicortical Anchorage on Implant Stress Distribution. https://app.cochat.ai/papers/10.1111/j.1708-8208.2003.tb00208.x
- The paper
- Pierrisnard, L., Renouard, F., Renault, P., & Barquins, M. (2003). Influence of Implant Length and Bicortical Anchorage on Implant Stress Distribution. Clinical Implant Dentistry and Related Research. https://doi.org/10.1111/j.1708-8208.2003.tb00208.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.