Surface Roughness of Nanofill and Nanohybrid Resin Composites after Polishing and Brushing
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
Purpose: The purpose of this study was to compare the surface roughness of nanofill (Filtek Supreme XT dentin shade and transparent shade, Filtek Z350, and Estelite Sigma), nanohybrid (Tetric EvoCeram, Ceram X, and Premise), and microhybrid resin composites (Filtek Z250, Tetric Ceram, and Clearfil AP‐X) with the materials after polishing or brushing. Materials and Methods: Forty specimens of each resin composite were polymerized for 40 seconds under a matrix strip in cylindrical molds. Each type of polymer was divided into four subgroups: unpolished, polished with abrasive disks (Sof‐Lex), polished with silicone‐impregnated polishing devices (Astropol), and brushed with a toothbrush (Oral B) and toothpaste (Colgate). The surface roughness of each specimen was determined using a contact stylus profilometer and by observation under a scanning electron microscope. Results: No significant differences in surface roughness among the materials were found on unpolished surfaces. For the nanofill resin composites, there were no significant differences in surface roughness between the two polishing methods or among the unpolished surfaces. After brushing, the surfaces of all materials, except those made from Filtek Z350 and Filtek Supreme XT (dentin), had greater roughness than unpolished surfaces and surfaces polished with either abrasive disks or silicone devices. The scanning electron microscope studies revealed that the surface irregularities of the materials corresponded to the results obtained using the surface roughness tester. CLINICAL SIGNIFICANCE: The use of nanofill resin composites made with nanoclusters demonstrated the smoothest surfaces after polishing and brushing. (J Esthet Restor Dent 19:265–275, 2007)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bollenl, C. M. L., Lambrechts, P., & Quirynen, M. (1997) · Dental Materials · doi:10.1016/s0109-5641(97)80038-3 · Cited by 1,911
Plaque accumulation on composite surfaces after various finishing procedures
Weitman, R. T., & Eames, W. B. (1975) · The Journal of the American Dental Association · doi:10.14219/jada.archive.1975.0294 · Cited by 249
Effects of finishing and polishing procedures on the surface texture of resin composites
Chung, K.-H. (1994) · Dental Materials · doi:10.1016/0109-5641(94)90041-8 · Cited by 185
Direct posterior restorations: clinical results and new developments
Manhart, J., García-Godoy, F., & Hickel, R. (2002) · Dental Clinics of North America · doi:10.1016/s0011-8532(01)00010-6 · Cited by 126
The polishability of posterior composites
Tjan, A. H. L., & Chan, C. A. (1989) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(89)90361-2 · Cited by 97
Influence of a composite resin restoration on the gingiva
Larato, D. C. (1972) · Journal of Prosthetic Dentistry · doi:10.1016/0022-3913(72)90241-7 · Cited by 96
Finishing and polishing of direct posterior resin restorations.
Morgan, M. (2004) · PubMed · Cited by 79
Cited by
Gönülol, N., & Yılmaz, F. (2012) · Journal of Dentistry · doi:10.1016/j.jdent.2012.07.005 · Cited by 232
Antonson, S. A., Yazici, A. R., Kilinc, E., Antonson, D. E., & Hardigan, P. C. (2011) · Journal of Dentistry · doi:10.1016/j.jdent.2011.01.006 · Cited by 186
Nanohybrid Resin Composites: Nanofiller Loaded Materials or Traditional Microhybrid Resins?
Moraes, R. R., Gonçalves, L. S., Lancellotti, A. C., Consani, S., Correr-Sobrinho, L., & Sinhoreti, M. A. (2009) · Operative Dentistry · doi:10.2341/08-043-l · Cited by 184
“In addition to traditional microhybrid and microfilled materials, nanofilled and nanohybrid composites were more recently introduced in an endeavor to provide a material presenting high initial polishing combined with superior polish and gloss retention.(3,5-10) Nevertheless, while nanofilled composites use nanosized…”
BackgroundInfluence of filler characteristics on the performance of dental composites: A comprehensive review
Elfakhri, F., Alkahtani, R., Li, C., & Khaliq, J. (2022) · Ceramics International · doi:10.1016/j.ceramint.2022.06.314 · Cited by 183
“The addition of PPRF also decreases the polymer-isation shrinkage and improves polish ability when compared to conventionally filled resin composites [65,66].”
BackgroundJanus, J., Fauxpoint, G., Arntz, Y., Pelletier, H., & Etienne, O. (2010) · Dental Materials · doi:10.1016/j.dental.2009.09.014 · Cited by 164
“They exhibit a higher surface quality, better polish and gloss, an increased retention as well as an ncreased wear resistance [4,5,12–18].”
BackgroundResultInfluential
Metadata
- Authors
- SENAWONGSE, P., & PONGPRUEKSA, P.
- Venue
- Journal of Esthetic and Restorative Dentistry
- Publisher
- Wiley
- Published
- 2007-09-14
- Volume
- 19
- Issue
- 5
- Pages
- 265-273
- ISSN
- 1496-4155 (ISSN-L)
- 1708-8240
- OpenAlex
- W2158794995
- Cited by
- 221
- References
- 7
- FWCI
- 9.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.