The DOI matches its Crossref record.
A Brief Overview on Automotive Exhaust Gas Sensors Based on Electroceramics
Abstract
Nowadays, ceramic exhaust gas sensors are installed in quantities of millions in automotive exhaust gas systems. Almost any automobile being powered by a gasoline combustion engine is equipped with at least one zirconia exhaust gas oxygen sensor (λ probe) for detection of the air‐to‐fuel ratio λ. The first part of this short overview focuses on potentiometric as well as on amperometric zirconia exhaust gas oxygen sensors. It is remarkable that in the past years a leap in manufacturing technology has occurred from classical ceramic technology to tape and thick‐film technology. The advent of novel combustion concepts like lean‐burn operating gasoline direct injection required novel exhaust gas aftertreatment concepts. It pushed the development of the NO x sensor, which is manufactured in the same technology. It is also shown how development of exhaust gas sensors has always to be considered in interaction with exhaust gas aftertreatment systems. This elucidates why novel sensors have gained in importance just recently when stricter emission regulations were announced, meaning that the time is ripe for novel exhaust gas aftertreatment concepts. Appropriate sensors—ammonia sensors, hydrocarbon sensors, and particulate matter sensors—are still in the R&D stage. Several possible sensor principles are discussed. The materials that are used for sensors in the automotive exhaust are electroceramics. Besides ion‐conducting zirconia and zirconia cermets, electrically insulating alumina is used for substrate purposes. Novel functional materials in the R&D state are strontium–iron titanate for temperature‐independent resistive oxygen sensing and zeolites for selective detection of specific gases like hydrocarbons or ammonia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Membrane electrolysis—History, current status and perspective
Paidar, M., Fateev, V., & Bouzek, K. (2016) · Electrochimica Acta · doi:10.1016/j.electacta.2016.05.209 · Cited by 357
Semiconducting Metal Oxides: SrTiO3, BaTiO3 and BaSrTiO3 in Gas-Sensing Applications: A Review
Szafraniak, B., Fuśnik, Ł., Xu, J., Gao, F., Brudnik, A., & Rydosz, A. (2021) · Coatings · doi:10.3390/coatings11020185 · Cited by 102
Aranthady, C., Jangid, T., Gupta, K., Mishra, A. K., Kaushik, S. D., Siruguri, V., Rao, G. M., Shanbhag, G. V., & Sundaram, N. G. (2021) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2020.129211 · Cited by 75
Metadata
- Authors
- Moos, R.
- Venue
- International Journal of Applied Ceramic Technology
- Publisher
- Wiley
- Published
- 2005-09
- Volume
- 2
- Issue
- 5
- Pages
- 401-413
- ISSN
- 1546-542X (ISSN-L)
- 1744-7402
- OpenAlex
- W2135202804
- Cited by
- 210
- References
- 0
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Brief Overview on Automotive Exhaust Gas Sensors Based on Electroceramics. https://app.cochat.ai/papers/10.1111/j.1744-7402.2005.02041.x
- The paper
- Moos, R. (2005). A Brief Overview on Automotive Exhaust Gas Sensors Based on Electroceramics. International Journal of Applied Ceramic Technology. https://doi.org/10.1111/j.1744-7402.2005.02041.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.