Abstract
We present the first stringent tests of a novel calibration system based on a laser frequency comb (LFC) for radial velocity measurements. The tests were obtained with the high-resolution, optical spectrograph, High Accuracy Radial velocity Planet Searcher. By using only one echelle order, we obtain a calibration repeatability of 15cms−1 for exposures that are several hours apart. This is comparable with a simultaneous calibration using a Th–Ar lamp that makes use of all 72 echelle orders. In both cases, the residuals are compatible with the computed photon noise. Averaging all LFC exposures, recorded over a few hours, we could obtain a calibration curve with residuals of 2.4ms−1. Thanks to the adjustable and optimally chosen line density of the LFC, we resolve a periodicity of 512 pixels in the calibration curve that is due to the manufacturing process of the CCD mask. Previous Th–Ar calibration was unable to resolve these systematic deviations, resulting in a deviation of up to 70ms−1 from the true calibration curve. In future, we hope to be able to make use of all echelle orders in order to obtain a calibration repeatability below 1cms−1 and absolute calibration within a few ms−1.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Search for Time Variation of the Fine Structure Constant
Webb, J. K., Flambaum, V. V., Churchill, C. W., Drinkwater, M. J., & Barrow, J. D. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.884 · Cited by 754 · cited 1×
“Another critical application that will benefit from improved calibration is the search for a possible variability of the physical constants (e.g. Webb et al. 1999; Reinhold et al. 2006).”
Background
Cited by
The evolving optical frequency comb [Invited]
Diddams, S. A. (2010) · Journal of the Optical Society of America B · doi:10.1364/josab.27.000b51 · Cited by 615
Parriaux, A., Hammani, K., & Millot, G. (2020) · Advances in Optics and Photonics · doi:10.1364/aop.382052 · Cited by 385
A spectrograph for exoplanet observations calibrated at the centimetre-per-second level
Wilken, T., Curto, G. L., Probst, R. A., Steinmetz, T., Manescau, A., Pasquini, L., González Hernández, J. I., Rebolo, R., Hänsch, T. W., Udem, T., et al. (2012) · Nature · doi:10.1038/nature11092 · Cited by 302
Self-citationMolaro, P., Centurión, M., Whitmore, J. B., Evans, T. M., Murphy, M. T., Agafonova, I. I., Bonifacio, P., D’Odorico, S., Levshakov, S. A., Lopez, S., et al. (2013) · Astronomy & Astrophysics · doi:10.1051/0004-6361/201321351 · Cited by 111
“Wilken et al. (2010) on spectra obtained with the HARPS spectrograph at the 3.6m ESO telescope on La Silla, and calibrated by means of a Laser Frequency Comb detected very small differences in the size of physical pixels due to CCD manufacturing.”
MethodImpact of instrumental systematic errors on fine-structure constant measurements with quasar spectra
Whitmore, J. B., & Murphy, M. T. (2014) · Monthly Notices of the Royal Astronomical Society · doi:10.1093/mnras/stu2420 · Cited by 99
Metadata
- Authors
- Wilken, T., Lovis, C., Manescau, A., Steinmetz, T., Pasquini, L., Lo Curto, G., Hänsch, T. W., Holzwarth, R., & Udem, T.
- Venue
- Monthly Notices of the Royal Astronomical Society: Letters
- Publisher
- Oxford University Press (OUP)
- Published
- 2010-06-01
- Volume
- 405
- Issue
- 1
- Pages
- L16-L20
- ISSN
- 1745-3925 (ISSN-L)
- 1745-3933
- OpenAlex
- W1916451807
- Cited by
- 138
- References
- 1
- FWCI
- 15.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.