A nondestructive method of determining milk coagulation cut‐time was investigated. Velocity and attenuation of ultrasonic waves through coagulating skim milk were measured after rennet addition. the ultrasonic attenuation measurements were found suitable for distinguishing the effect of different experimental variables (three levels of temperature, rennet and CaCl 2). Based on the rate of change of attenuation during coagulation, a turning point was defined at which the attenuation rate change was ‐0.1 neper/m/min. the cut‐time was proposed to be 20 min from the time the turning point was observed. the cut‐times predicted by this criterion were statistically similar to those predicted by the manual method currently used in the industry.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1745-4530.1996.tb00381.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 59

Metadata

Authors
GUNASEKARAN, S., & AY, C.
Venue
Journal of Food Process Engineering
Publisher
Wiley
Published
1996-04
Volume
19
Issue
1
Pages
63-73
ISSN
  • 0145-8876 (ISSN-L)
  • 1745-4530
OpenAlex
W2161587036
Cited by
59
References
0
FWCI
2.37
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: MILK COAGULATION CUT‐TIME DETERMINATION USING ULTRASONICS. https://app.cochat.ai/papers/10.1111/j.1745-4530.1996.tb00381.x
The paper
GUNASEKARAN, S., & AY, C. (1996). MILK COAGULATION CUT‐TIME DETERMINATION USING ULTRASONICS. Journal of Food Process Engineering. https://doi.org/10.1111/j.1745-4530.1996.tb00381.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.