Measurements of the Blood Flow through the Lungs of Man1
Open accessThe DOI matches its Crossref record.
Abstract
1 Our expectations were baaed upon current notions regarding the blood flow and especially upon the argumentation given by Bohr, Skmnd.Arch.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Jernérus, R., Lundin, G., & Pugh, L. G. C. F. (1963) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1963.tb02717.x · Cited by 447
Respiration, Stress, and Cardiovascular Function
Grossman, P. (1983) · Psychophysiology · doi:10.1111/j.1469-8986.1983.tb02156.x · Cited by 386
Bevegård, B. S., Holmgren, A., & Jonsson, B. (1963) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1963.tb02572.x · Cited by 289
Jacobs, R. A., Flück, D., Bonne, T. C., Bürgi, S., Christensen, P. M., Toigo, M., & Lundby, C. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00445.2013 · Cited by 268
Montero, D., Cathomen, A., Jacobs, R. A., Flück, D., de Leur, J., Keiser, S., Bonne, T., Kirk, N., Lundby, A., & Lundby, C. (2015) · The Journal of Physiology · doi:10.1113/jp270250 · Cited by 195
“Briefly, the measurement is based on the assumption that pulmonary uptake of a blood soluble testing gas is proportional to pulmonary blood flow (Krogh & Lindhard, 1912).”
Metadata
- Authors
- Krogh, A., & Lindhard, J.
- Venue
- Skandinavisches Archiv Für Physiologie
- Publisher
- Wiley
- Published
- 1912-07
- Volume
- 27
- Issue
- 2
- Pages
- 100-125
- ISSN
- 0370-839X (ISSN-L)
- OpenAlex
- W2034106249
- Cited by
- 157
- References
- 0
- FWCI
- 15.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Measurements of the Blood Flow through the Lungs of Man1. https://app.cochat.ai/papers/10.1111/j.1748-1716.1912.tb00640.x
- The paper
- Krogh, A., & Lindhard, J. (1912). Measurements of the Blood Flow through the Lungs of Man1. Skandinavisches Archiv Für Physiologie. https://doi.org/10.1111/j.1748-1716.1912.tb00640.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.