The DOI matches its Crossref record.
Conduction Velocity and Amplitude of the Action Potential as Related to Circumference in the Isolated Fibre of Frog Muscle
Abstract
Summary.: 1. Conduction velocity and amplitude of the action potential and fibre circumference were measured in isolated frog muscle fibres in a large volume of Ringer's solution. 2. Conduction velocity was found to be a linear function of fibre circumference. 3. The velocity in a fibre of 100 μ diameter (circumference 314 μ) at 20°C was 2.44 & 0.05 m/sec. for spring frogs and 2.05 & 0.07 m/sec. for winter frogs. The total range in eonduction velocity at 20°C was 1.2–3.1 m/sec. for spring frogs and 1.0–2.76 m/sec. for winter frogs. 4. The amplitude of the action potential, both at constant distance from the fibre surface and at 500 μ from the midpoint of the fibre, was relatively greater in fibres with large than in fibres with small circumference. 5. The amplitude decreased steeply with electrode distance from the fibre up to 200 μ, and reached one tenth of the maximally measured value at a distance of about 600 μ. At equal distance the amplitude was 20 per cent smaller when the electrode faced the rounded side of an elliptical fibre, than when it faced the flat surface (large diameter twice the small). 6. The findings with respect to conduction velocity and amplitude as a function of circumference are interpreted to indicate that the specific electrical properties of the membrane differ according to fibre size.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
ATS/ERS Statement on Respiratory Muscle Testing
(2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.166.4.518 · Cited by 2,841
The relation between the surface electromyogram and muscular force.
Milner‐Brown, H. S., & Stein, R. B. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp010904 · Cited by 644
Effects of muscle fiber type and size on EMG median frequency and conduction velocity
Kupa, E. J., Roy, S. H., Kandarian, S. C., & De Luca, C. J. (1995) · Journal of Applied Physiology · doi:10.1152/jappl.1995.79.1.23 · Cited by 458
Interpretation of myoelectric power spectra: A model and its applications
Lindstrom, L. H., & Magnusson, R. I. (1977) · Proceedings of the IEEE · doi:10.1109/proc.1977.10544 · Cited by 419
Tutorial: Analysis of motor unit discharge characteristics from high-density surface EMG signals
Del Vecchio, A., Holobar, A., Falla, D., Felici, F., Enoka, R. M., & Farina, D. (2020) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2020.102426 · Cited by 372
Metadata
- Authors
- HAKANSSON, C. H.
- Venue
- Acta Physiologica Scandinavica
- Publisher
- Wiley
- Published
- 1956-01
- Volume
- 37
- Issue
- 1
- Pages
- 14-34
- ISSN
- 0001-6772 (ISSN-L)
- 1365-201X
- OpenAlex
- W2038289422
- Cited by
- 223
- References
- 0
- FWCI
- 2.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Conduction Velocity and Amplitude of the Action Potential as Related to Circumference in the Isolated Fibre of Frog Muscle. https://app.cochat.ai/papers/10.1111/j.1748-1716.1956.tb01338.x
- The paper
- HAKANSSON, C. H. (1956). Conduction Velocity and Amplitude of the Action Potential as Related to Circumference in the Isolated Fibre of Frog Muscle. Acta Physiologica Scandinavica. https://doi.org/10.1111/j.1748-1716.1956.tb01338.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.