Flow and Composition of Leg Lymph in Normal Men during Venous Stasis, Muscular Activity and Local Hyperthermia
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Changes in normal human leg lymph protein concentration, output, and lymph flow/lymph protein concentration relationship, as well as lactate dehydrogenase and alkaline phosphatase activity were followed during procedures known to increase capillary filtration as venous stasis, muscular exercise and warming of tissues. Lymph flow increased by 83% during two hour ergometer cycling, and by 117% during two hour warm water foot bath. During a two hour period of venous stasis lymph flow dropped by 50%. There was an increase in lymph flow during the rest period following all three types of experiment, most pronounced after foot warming. An inverse relationship between the lymph flow rate and lymph protein concentration was found. Lymph enzymes followed the same pattern of changes as total protein.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Twenty‐Four Hour Variation in Flow and Composition of Leg Lymph in Normal Men
Engeset, A., Olszewski, W., Jæger, P. M., Sokolowski, J., & Theodorsen, L. (1977) · Acta Physiologica Scandinavica · doi:10.1111/j.1748-1716.1977.tb10364.x · Cited by 78
Self-citation
Cited by
Pharmacokinetics of Monoclonal Antibodies
Ryman, J. T., & Meibohm, B. (2017) · CPT: Pharmacometrics & Systems Pharmacology · doi:10.1002/psp4.12224 · Cited by 802
The physiology of the lymphatic system
Swartz, M. (2001) · Advanced Drug Delivery Reviews · doi:10.1016/s0169-409x(01)00150-8 · Cited by 737
Hamadani, A., Haigh, P. I., Liu, I.-L. A., & Abbas, M. A. (2009) · Diseases of the Colon & Rectum · doi:10.1007/dcr.0b013e31819a5c52 · Cited by 453
Mechanistic Determinants of Biotherapeutics Absorption Following SC Administration
Richter, W. F., Bhansali, S. G., & Morris, M. E. (2012) · The AAPS Journal · doi:10.1208/s12248-012-9367-0 · Cited by 377
“lymph flow and hence lymphatic transport of proteins (59).”
BackgroundLymphatic Vessel Network Structure and Physiology
Breslin, J. W., Yang, Y., Scallan, J. P., Sweat, R. S., Adderley, S. P., & Murfee, W. L. (2018) · Comprehensive Physiology · doi:10.1002/cphy.c180015 · Cited by 341
Metadata
- Authors
- Olszewski, W., Engeset, A., Icger, P. M., Sokolowski, J., & Theodorsen, L.
- Venue
- Acta Physiologica Scandinavica
- Publisher
- Wiley
- Published
- 1977-02
- Volume
- 99
- Issue
- 2
- Pages
- 149-155
- ISSN
- 0001-6772 (ISSN-L)
- 1365-201X
- OpenAlex
- W2006975935
- Cited by
- 127
- References
- 1
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flow and Composition of Leg Lymph in Normal Men during Venous Stasis, Muscular Activity and Local Hyperthermia. https://app.cochat.ai/papers/10.1111/j.1748-1716.1977.tb10365.x
- The paper
- Olszewski, W., Engeset, A., Icger, P. M., Sokolowski, J., & Theodorsen, L. (1977). Flow and Composition of Leg Lymph in Normal Men during Venous Stasis, Muscular Activity and Local Hyperthermia. Acta Physiologica Scandinavica. https://doi.org/10.1111/j.1748-1716.1977.tb10365.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.