INTRAOPERATIVE MONITORING OF EVOKED POTENTIALS
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Sensory EPs were recorded intraoperatively in 173 neurosurgical procedures (71 VEPs, 66 BAEPs, and 31 SSEPs) to evaluate the utility of this technique. EPs could be safely recorded in all cases, but the yield of useful results varied with each sensory modality. BAEPs were recorded reliably in 100% of the cases and intraoperative latency changes accurately predicted postoperative hearing deficits in 10%. Potential hearing deficits were detected in another 15%. BAEP changes were associated with brainstem dysfunction in only one case. VEP changes were difficult to interpret intraoperatively because of contamination by a high degree of variability and both false negative and false positive results. Changes in VEP amplitudes related to surgical manipulation of the optic chiasm were only suggested. SSEP changes were recorded reliably in only 75% of the cases and no correlations between SSEP changes and postoperative sensory function were established. Again, intraoperative amplitude attenuation of the SSEP waveform with surgical manipulation only suggested a potential sensory deficit. Intraoperative EP monitoring is a valuable technique that provides a functional analysis of the sensory nervous system during surgical procedures. Specific sensory stimuli and improved data analysis will increase the utility of this CNS monitor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Visual Evoked Potentials in Man: New Developments
Mcgeorge, A. P. (1978) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.41.6.579-a · Cited by 431
Nonpathologic Factors Influencing Brainstem Auditory Evoked Potentials
Stockard, J. J., Stockard, J. E., & Sharbrough, F. W. (1978) · American Journal of EEG Technology · doi:10.1080/00029238.1978.11106793 · Cited by 330
Detection and Localization of Occult Lesions With Brainstem Auditory Responses
Stockard, J. J., Stockard, J. E., & Sharbrough, F. W. (1977) · Mayo Clinic Proceedings · doi:10.1016/s0025-6196(25)09937-9 · Cited by 229
Stockard, J. J., Hughes, J. F., & Sharbrough, F. W. (1979) · American Journal of EEG Technology · doi:10.1080/00029238.1979.11079986 · Cited by 123
Central conduction time as an index of ischaemia in subarachnoid haemorrhage
Symon, L., Mackey-Hargadine, J. R., Zawirski, M., & Branston, N. M. (1979) · Journal of the Neurological Sciences · doi:10.1016/0022-510x(79)90227-2 · Cited by 115
Arterial Pressure Manipulation Alters Spinal Cord Function during Correction of Scoliosis
Grundy, B. L., Nash, C. L., & Brown, R. H. (1981) · Anesthesiology · doi:10.1097/00000542-198103000-00014 · Cited by 75
Effect of Halothane Anesthesia on the Human Cortical Visual Evoked Response
Uhl, R. R., Squires, K. C., Bruce, D. L., & Starr, A. (1980) · Anesthesiology · doi:10.1097/00000542-198010000-00001 · Cited by 71
Creel, D. J., & Yu, M. (2019) · Springer eBooks · doi:10.1007/978-3-030-30417-1_2 · Cited by 29
Regan, D. (1976) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(76)90140-1 · Cited by 28
Cited by
Electrophysiology of Cognition
Hillyard, S. A., & Picton, T. W. (1987) · Comprehensive Physiology · doi:10.1002/cphy.cp010513 · Cited by 391
Boyd, S. G., Rothwell, J. C., Cowan, J. M., Webb, P. J., Morley, T., Asselman, P., & Marsden, C. D. (1986) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.49.3.251 · Cited by 329
Banoub, M., Tetzlaff, J. E., & Schubert, A. (2003) · Anesthesiology · doi:10.1097/00000542-200309000-00029 · Cited by 299
“Although satisfactory intraoperative recordings can be obtained in the majority of patients, clinical observations suggest a high incidence of false-positive and false-negative results.(170) Anesthetic technique can affect the incidence of false-positive VEP changes.”
BackgroundIntraoperative monitoring of brain-stem auditory evoked potentials
Grundy, B. L., Jannetta, P. J., Procopio, P. T., Lina, A., Boston, J. R., & Doyle, E. (1982) · Journal of Neurosurgery · doi:10.3171/jns.1982.57.5.0674 · Cited by 210
Møller, A. R., & Jannetta, P. J. (1983) · Journal of Neurosurgery · doi:10.3171/jns.1983.59.3.0493 · Cited by 158
Metadata
- Authors
- Raudzens, P. A.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 1982-06
- Volume
- 388
- Issue
- 1
- Pages
- 308-325
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W1986624423
- Cited by
- 178
- References
- 9
- FWCI
- 12.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.