The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Impulsive Testing of Semicircular‐Canal Function Using Video‐oculography
Abstract
The head impulse test (HIT) is a safe, quick way of assessing horizontal semicircular‐canal function in patients with peripheral vestibular loss. At the bedside, the clinician identifies “overt” catch‐up saccades back to the target after brisk passive head rotation as an indirect sign of canal paresis. However, saccades during head rotation (“covert” saccades) may not be detectable by the naked eye, and so lead to incorrect diagnosis. Up to now, the scleral search coil technique has been the standard for HIT measurement, but that technique is not practical for routine diagnostic use. A new lightweight, nonslip, high‐speed video‐oculography system (vHIT) that measures eye velocity during horizontal head impulses has been developed. This system is easy to use in a clinical setting, provides an objective measure of the vestibulo‐ocular reflex (VOR), and detects both overt and covert catch‐up saccades in patients with vestibular loss.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Method of Measuring Eye Movemnent Using a Scieral Search Coil in a Magnetic Field
(1963) · IEEE Transactions on Bio-medical Electronics · doi:10.1109/tbmel.1963.4322822 · Cited by 1,838
A method of measuring eye movements using a scleral search coil in a magnetic field
Robinson, D. A. (1963) · Medical Entomology and Zoology · Cited by 1,709
A Clinical Sign of Canal Paresis
Halmagyi, G. M., & Curthoys, I. S. (1988) · Archives of Neurology · doi:10.1001/archneur.1988.00520310043015 · Cited by 1,284
Self-citationMaximum permissible exposures for ocular safety (ANSI 2000), with emphasis on ophthalmic devices
Delori, F. C., Webb, R. H., & Sliney, D. H. (2007) · Journal of the Optical Society of America A · doi:10.1364/josaa.24.001250 · Cited by 480
Head impulse test in unilateral vestibular loss: Vestibulo-ocular reflex and catch-up saccades
Weber, K. P., Aw, S. T., Todd, M. J., McGarvie, L. A., Curthoys, I. S., & Halmagyi, G. M. (2008) · Neurology · doi:10.1212/01.wnl.0000299117.48935.2e · Cited by 435
Self-citationNormal head impulse test differentiates acute cerebellar strokes from vestibular neuritis
Newman-Toker, D. E., Kattah, J. C., Alvernia, J. E., & Wang, D. Z. (2008) · Neurology · doi:10.1212/01.wnl.0000314685.01433.0d · Cited by 386
Bedside differentiation of vestibular neuritis from central "vestibular pseudoneuritis"
Cnyrim, C. D., Newman-Toker, D., Karch, C., Brandt, T., & Strupp, M. (2008) · Journal of Neurology, Neurosurgery & Psychiatry · doi:10.1136/jnnp.2007.123596 · Cited by 260
Aw, S. T., Haslwanter, T., Halmagyi, G. M., Curthoys, I. S., Yavor, R. A., & Todd, M. J. (1996) · Journal of Neurophysiology · doi:10.1152/jn.1996.76.6.4009 · Cited by 203
Self-citationAn Inexpensive Eye Movement Monitor Using the Scleral Search Coil Technique
Remmel, R. S. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325352 · Cited by 172
Cited by
Strupp, M., Kim, J.-S., Murofushi, T., Straumann, D., Jen, J. C., Rosengren, S. M., Della Santina, C. C., & Kingma, H. (2017) · Journal of Vestibular Research · doi:10.3233/ves-170619 · Cited by 592
“Thereby, the gain of the aVOR can be determined and catch-up saccades can be detected even if they are of short latency and already occur during the head impulses (covert catch-up saccades) [31, 32, 41].”
BackgroundHINTS Outperforms ABCD 2 to Screen for Stroke in Acute Continuous Vertigo and Dizziness
Newman‐Toker, D. E., Kerber, K. A., Hsieh, Y., Pula, J. H., Omron, R., Saber Tehrani, A. S., Mantokoudis, G., Hanley, D. F., Zee, D. S., & Kattah, J. C. (2013) · Academic Emergency Medicine · doi:10.1111/acem.12223 · Cited by 385
Hall, C. D., Herdman, S. J., Whitney, S. L., Anson, E. R., Carender, W. J., Hoppes, C. W., Cass, S. P., Christy, J. B., Cohen, H. S., Fife, T. D., et al. (2022) · Journal of Neurologic Physical Therapy · doi:10.1097/npt.0000000000000382 · Cited by 371
Metadata
- Authors
- Weber, K. P., MacDougall, H. G., Halmagyi, G. M., & Curthoys, I. S.
- Venue
- Annals of the New York Academy of Sciences
- Publisher
- Wiley
- Published
- 2009-05
- Volume
- 1164
- Issue
- 1
- Pages
- 486-491
- ISSN
- 0077-8923 (ISSN-L)
- 1749-6632
- OpenAlex
- W2079252099
- Cited by
- 306
- References
- 9
- FWCI
- 3.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impulsive Testing of Semicircular‐Canal Function Using Video‐oculography. https://app.cochat.ai/papers/10.1111/j.1749-6632.2008.03730.x
- The paper
- Weber, K. P., MacDougall, H. G., Halmagyi, G. M., & Curthoys, I. S. (2009). Impulsive Testing of Semicircular‐Canal Function Using Video‐oculography. Annals of the New York Academy of Sciences. https://doi.org/10.1111/j.1749-6632.2008.03730.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.