The DOI matches its Crossref record.
A Method of Measuring Eye Movemnent Using a Scieral Search Coil in a Magnetic Field
Abstract
With the subject exposed to an alternating magnetic field, eye position may be accurately recorded from the voltage generated in a coil of wire embedded in a scleral contact lens worn by the subject. Using two magnetic fields in quadrature phase and two coils on the lens, one may measure horizontal, vertical and torsional eye movements simultaneously. The instrument described has an accuracy and linearity of about 2 per cent of full scale, a resolution of 15 seconds of arc and a bandwidth of 1000 cyles per second.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Newsome, W., & Pare, E. (1988) · The Journal of Neuroscience · doi:10.1523/jneurosci.08-06-02201.1988 · Cited by 1,615
Memory related motor planning activity in posterior parietal cortex of macaque
Gnadt, J. W., & Andersen, R. A. (1988) · Experimental Brain Research · doi:10.1007/bf00271862 · Cited by 998
Contextual modulation in primary visual cortex
Zipser, K., Lamme, V. A. F., & Schiller, P. H. (1996) · The Journal of Neuroscience · doi:10.1523/jneurosci.16-22-07376.1996 · Cited by 873
The mechanics of human saccadic eye movement
Robinson, D. A. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007485 · Cited by 893
Self-citationIntegration of What and Where in the Primate Prefrontal Cortex
Rao, S. C., Rainer, G., & Miller, E. K. (1997) · Science · doi:10.1126/science.276.5313.821 · Cited by 874
Metadata
- Venue
- IEEE Transactions on Bio-medical Electronics
- Published
- 1963-10
- Volume
- 10
- Issue
- 4
- Pages
- 137-145
- ISSN
- 0096-0616 (ISSN-L)
- 2168-1600
- OpenAlex
- W2113705163
- Cited by
- 1,838
- References
- 0
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Method of Measuring Eye Movemnent Using a Scieral Search Coil in a Magnetic Field. https://app.cochat.ai/papers/10.1109/tbmel.1963.4322822
- The paper
- A Method of Measuring Eye Movemnent Using a Scieral Search Coil in a Magnetic Field. (1963). IEEE Transactions on Bio-medical Electronics. https://doi.org/10.1109/tbmel.1963.4322822
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.