Reflectance Confocal Microscopy for In Vivo Skin Imaging†
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Reflectance confocal microscopy (RCM) is a novel noninvasive technique for “in vivo” examination of the skin. In a confocal microscope, near‐ infrared light from a diode laser is focused on a microscopic skin target. As this light passes between cellular structures having different refraction indexes, it is naturally reflected, and this reflected light is then captured and recomposed into a two‐dimensional gray scale image by computer software. Focusing the microscope (adjusting the focal point on the z‐axis) allows images to be obtained of different levels within the skin. Commercially available microscope systems of this type can create images with enough detail for use in histological analysis. The first investigations using these microscopes served to identify the appearance of the various cell populations living in the different layers of normal skin. Today, the main interest has become focused on the use of these microscopes as a diagnostic tool: a means of investigating benign and malignant tumors of melanocytes and keratinocytes, and, more importantly, the findings of this field of study can be used to develop a diagnostic algorithm which would be not only highly sensitive but specific as well. The aim of the paper is to provide an updated literature review and an in‐depth critique of the state‐of‐the‐art of RCM for skin cancer imaging with a critical discussion of the possibilities and limitations for clinical use.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, R. R., & Parrish, J. A. (1981) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12479191 · Cited by 2,456 · cited 2×
“moving average of the matrix of 3 · 3 pixels using triangular kernels), and contrast adjustment (13).”
BackgroundMethodPehamberger, H., Steiner, A., & Wolff, K. (1987) · Journal of the American Academy of Dermatology · doi:10.1016/s0190-9622(87)70239-4 · Cited by 634 · cited 1×
“dermoscopy and digital epiluminescence (2), high frequency ultrasonography (3), optical coherence tomography (4), magnetic resonance imaging (5) and reflectance confocal micros-”
Background
Cited by
Gupta, V., & Trivedi, P. (2018) · Lipid Nanocarriers for Drug Targeting · doi:10.1016/b978-0-12-813687-4.00015-3 · Cited by 96
Ritelli, M., Cinquina, V., Venturini, M., Pezzaioli, L., Formenti, A. M., Chiarelli, N., & Colombi, M. (2019) · Genes · doi:10.3390/genes10020135 · Cited by 33
Self-citationLe Blay, H., Raynaud, E., Bouayadi, S., Rieux, E., Rolland, G., Saussine, A., Jachiet, M., Bouaziz, J., & Lynch, B. (2024) · Skin Research and Technology · doi:10.1111/srt.13891 · Cited by 12
“11 Despite being well studied, multiple questions remain with regards 12 Multi-photon Microscopy (MMP), 13 and Optical Coherence Tomography (OCT) 14 were also segmented from 3D LC-OCT stacks to develop specific metrics, such as cell density, nuclei size and shape 19 through the training of a Deep…”
Background
Metadata
- Authors
- Calzavara‐Pinton, P., Longo, C., Venturini, M., Sala, R., & Pellacani, G.
- Venue
- Photochemistry and Photobiology
- Publisher
- Wiley
- Published
- 2008-11
- Volume
- 84
- Issue
- 6
- Pages
- 1421-1430
- ISSN
- 0031-8655 (ISSN-L)
- 1751-1097
- OpenAlex
- W2093749790
- Cited by
- 242
- References
- 2
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reflectance Confocal Microscopy for In Vivo Skin Imaging†. https://app.cochat.ai/papers/10.1111/j.1751-1097.2008.00443.x
- The paper
- Calzavara‐Pinton, P., Longo, C., Venturini, M., Sala, R., & Pellacani, G. (2008). Reflectance Confocal Microscopy for In Vivo Skin Imaging†. Photochemistry and Photobiology. https://doi.org/10.1111/j.1751-1097.2008.00443.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.