CoChat

A Critical Assessment of Two Types of Personal UV Dosimeters

Seckmeyer, Gunther, Klingebiel, Marcus, Riechelmann, Stefan, Lohse, Insa, McKenzie, Richard L., Ben Liley, J., Allen, Martin W., Siani, Anna‐Maria, Casale, Giuseppe R. · 2012 · Photochemistry and Photobiology
Cited by 50

The DOI matches its Crossref record.

Abstract

Doses of erythemally weighted irradiances derived from polysulphone (PS) and electronic ultraviolet (EUV) dosimeters have been compared with measurements obtained using a reference spectroradiometer. PS dosimeters showed mean absolute deviations of 26% with a maximum deviation of 44%, the calibrated EUV dosimeters showed mean absolute deviations of 15% (maximum 33%) around noon during several test days in the northern hemisphere autumn. In the case of EUV dosimeters, measurements with various cut‐off filters showed that part of the deviation from the CIE erythema action spectrum was due to a small, but significant sensitivity to visible radiation that varies between devices and which may be avoided by careful preselection. Usually the method of calibrating UV sensors by direct comparison to a reference instrument leads to reliable results. However, in some circumstances the quality of measurements made with simple sensors may be over‐estimated. In the extreme case, a simple pyranometer can be used as a UV instrument, providing acceptable results for cloudless skies, but very poor results under cloudy conditions. It is concluded that while UV dosimeters are useful for their design purpose, namely to estimate personal UV exposures, they should not be regarded as an inexpensive replacement for meteorological grade instruments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1751-1097.2011.01018.x

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 50

Metadata

Authors
Seckmeyer, G., Klingebiel, M., Riechelmann, S., Lohse, I., McKenzie, R. L., Ben Liley, J., Allen, M. W., Siani, A., & Casale, G. R.
Venue
Photochemistry and Photobiology
Publisher
Wiley
Published
2011-11-17
Volume
88
Issue
1
Pages
215-222
ISSN
  • 0031-8655 (ISSN-L)
  • 1751-1097
OpenAlex
W1971717414
Cited by
50
References
0
FWCI
9.16
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Critical Assessment of Two Types of Personal UV Dosimeters. https://app.cochat.ai/papers/10.1111/j.1751-1097.2011.01018.x
The paper
Seckmeyer, G., Klingebiel, M., Riechelmann, S., Lohse, I., McKenzie, R. L., Ben Liley, J., Allen, M. W., Siani, A., & Casale, G. R. (2012). A Critical Assessment of Two Types of Personal UV Dosimeters. Photochemistry and Photobiology. https://doi.org/10.1111/j.1751-1097.2011.01018.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.