Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 224

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Intrathoracic Impedance vs Daily Weight Monitoring for Predicting Worsening Heart Failure Events: Results of the Fluid Accumulation Status Trial (FAST)

Open access
Abraham, William T., Compton, Steven, Haas, Garrie, Foreman, Blair, Canby, Robert C., Fishel, Robert, McRae, Scott, Toledo, Gloria B., Sarkar, Shantanu, Hettrick, Douglas A., On behalf of the FAST Study Investigators · 2011 · Congestive Heart Failure

Abstract

The relative sensitivity and unexplained detection rate of changes in intrathoracic impedance has not been compared with standard heart failure (HF) monitoring using daily weight changes. The Fluid Accumulation Status Trial (FAST) prospectively followed 156 HF patients with implanted cardioverter-defibrillator or cardiac resynchronization therapy defibrillator devices modified to record daily changes in intrathoracic impedance in a blinded fashion for 537±312 days. Daily impedance changes were used to calculate a fluid index that could be compared with a prespecified threshold. True positives were defined as adjudicated episodes of worsening HF occurring within 30 days of a fluid index above threshold or an acute weight gain. Unexplained detections were defined as threshold crossings or acute weight gains not associated with worsening HF. Impedance measurements were performed on >99% of follow-up days, compared with only 76% of days for weight measurements. Sixty-five HF events occurred during follow-up (0.32/patient-year). Forty HF events were detected by impedance but not weight, whereas 5 were detected by weight but not impedance. Sensitivity was greater (76% vs 23%; P<.0001) and unexplained detection rate was lower (1.9 vs 4.3/patient-year; P<.0001) for intrathoracic impedance monitoring at the threshold of 60Ω days compared with acute weight increases of 3 lbs in 1 day or 5 lbs in 3 days and also over a wide range of fluid index and weight thresholds. The sensitivity and unexplained detection rate of intrathoracic impedance monitoring was superior to that seen for acute weight changes. Intrathoracic impedance monitoring represents a useful adjunctive clinical tool for managing HF in patients with implanted devices.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/j.1751-7133.2011.00220.x

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Cited by

See all 224

Metadata

Authors
Abraham, W. T., Compton, S., Haas, G., Foreman, B., Canby, R. C., Fishel, R., McRae, S., Toledo, G. B., Sarkar, S., Hettrick, D. A., & On behalf of the FAST Study Investigators
Venue
Congestive Heart Failure
Publisher
Wiley
Published
2011-03
Volume
17
Issue
2
Pages
51-55
ISSN
1527-5299 (ISSN-L)
OpenAlex
W1504239888
Cited by
224
References
2
FWCI
12.30
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intrathoracic Impedance vs Daily Weight Monitoring for Predicting Worsening Heart Failure Events: Results of the Fluid Accumulation Status Trial (FAST). https://app.cochat.ai/papers/10.1111/j.1751-7133.2011.00220.x
The paper
Abraham, W. T., Compton, S., Haas, G., Foreman, B., Canby, R. C., Fishel, R., McRae, S., Toledo, G. B., Sarkar, S., Hettrick, D. A., & On behalf of the FAST Study Investigators. (2011). Intrathoracic Impedance vs Daily Weight Monitoring for Predicting Worsening Heart Failure Events: Results of the Fluid Accumulation Status Trial (FAST). Congestive Heart Failure. https://doi.org/10.1111/j.1751-7133.2011.00220.x

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.