Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 444

The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.

Intrathoracic Impedance Monitoring, Audible Patient Alerts, and Outcome in Patients With Heart Failure

Open access
van Veldhuisen, Dirk J., Braunschweig, Frieder, Conraads, Viviane, Ford, Ian, Cowie, Martin R., Jondeau, Guillaume, Kautzner, Josef, Muñoz Aguilera, Roberto, Lunati, Maurizio, Yu, Cheuk Man, Gerritse, Bart, Borggrefe, Martin, for the DOT-HF Investigators·2011·Circulation

Abstract

Background—: Heart failure is associated with frequent hospitalizations, often resulting from volume overload. Measurement of intrathoracic impedance with an implanted device with an audible patient alert may detect increases in pulmonary fluid retention early. We hypothesized that early intervention could prevent hospitalizations and affect outcome. Methods and Results—: We studied 335 patients with chronic heart failure who had undergone implantation of an implantable cardioverter-defibrillator alone (18%) or with cardiac resynchronization therapy (82%). All devices featured a monitoring tool to track changes in intrathoracic impedance (OptiVol) and other diagnostic parameters. Patients were randomized to have information available to physicians and patients as an audible alert in case of preset threshold crossings (access arm) or not (control arm). The primary end point was a composite of all-cause mortality and heart failure hospitalizations. During 14.9±5.4 months, this occurred in 48 patients (29%) in the access arm and in 33 patients (20%) in the control arm ( P =0.063; hazard ratio, 1.52; 95% confidence interval, 0.97–2.37). This was due mainly to more heart failure hospitalizations (hazard ratio, 1.79; 95% confidence interval, 1.08–2.95; P =0.022), whereas the number of deaths was comparable (19 versus 15; P =0.54). The number of outpatient visits was higher in the access arm (250 versus 84; P <0.0001), with relatively more signs of heart failure among control patients during outpatient visits. Although the trial was terminated as a result of slow enrollment, a post hoc futility analysis indicated that a positive result would have been unlikely. Conclusion—: Use of an implantable diagnostic tool to measure intrathoracic impedance with an audible patient alert did not improve outcome and increased heart failure hospitalizations and outpatient visits in heart failure patients. Clinical Trial Registration—: URL: http://www.clinicaltrials.gov . Unique identifier: NCT 00480077.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1161/circulationaha.111.043042

Cites

29 of 29 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 29 references

Cited by

See all 444

Metadata

Authors
van Veldhuisen, D. J., Braunschweig, F., Conraads, V., Ford, I., Cowie, M. R., Jondeau, G., Kautzner, J., Muñoz Aguilera, R., Lunati, M., Yu, C. M., Gerritse, B., Borggrefe, M., & for the DOT-HF Investigators
Venue
Circulation
Published
2011-10-18
Volume
124
Issue
16
Pages
1719-1726
ISSN
  • 0009-7322 (ISSN-L)
  • 1524-4539
OpenAlex
W2162066049
Cited by
444
References
29
FWCI
23.17
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intrathoracic Impedance Monitoring, Audible Patient Alerts, and Outcome in Patients With Heart Failure. https://app.cochat.ai/papers/10.1161/circulationaha.111.043042
The paper
van Veldhuisen, D. J., Braunschweig, F., Conraads, V., Ford, I., Cowie, M. R., Jondeau, G., Kautzner, J., Muñoz Aguilera, R., Lunati, M., Yu, C. M., Gerritse, B., Borggrefe, M., & for the DOT-HF Investigators. (2011). Intrathoracic Impedance Monitoring, Audible Patient Alerts, and Outcome in Patients With Heart Failure. Circulation. https://doi.org/10.1161/circulationaha.111.043042

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.