U‐Pb Zircon Geochronology with an Integrated LA‐ICP‐MS Microanalytical Workstation: Achievements in Precision and Accuracy
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) is a microanalytical tool especially suitable for providing fast and precise U‐Pb geochronological results on zircon grains. A new 193 nm excimer laser adapted to a micromachining workstation, equipped with a newly designed two‐volume ablation cell and coupled with a quadrupole ICP‐MS, is presented here. The system was tuned routinely to achieve sensitivities in the range of 3000 cps/μg g−1 for 238 U (< 2% RSD), with a 34 μm spot size, at 5 Hz and ∼ 8 J cm−2, while ablating the NIST SRM 612 glass reference material. The system was capable of providing fast (< 1.5 minutes each analysis) and precise (generally < 1.5% 1s errors) 206 Pb/238 U zircon ages. The ages of widely used reference material zircons (Plesovice, 337 Ma; Temora, 416 Ma; R33, 418 Ma; Sri Lanka, 564 Ma; 91500, 1065 Ma) could be precisely matched, with an accuracy on isotopic ratios that ranged from ∼ 2 to ∼ 6%, depending on the homogeneity of the natural reference materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THREE NATURAL ZIRCON STANDARDS FOR U‐TH‐PB, LU‐HF, TRACE ELEMENT AND REE ANALYSES
WIEDENBECK, M., ALLÉ, P., CORFU, F., GRIFFIN, W. L., MEIER, M., OBERLI, F., QUADT, A. V., RODDICK, J. C., & SPIEGEL, W. (1995) · Geostandards Newsletter · doi:10.1111/j.1751-908x.1995.tb00147.x · Cited by 6,328 · cited 3×
“4 Ma (n=101, 2 sigma, Figure 6A), in good agreement with the ages reported by Wiedenbeck et al. (1995). The average analytical errors at the 2 sigma level for the 207Pb/235U, 206Pb/238U and 207Pb/206Pb isotopic ratios are 4.”
ResultInfluentialJackson, S. E., Pearson, N. J., Griffin, W. L., & Belousova, E. A. (2004) · Chemical Geology · doi:10.1016/j.chemgeo.2004.06.017 · Cited by 5,253 · cited 1×
“…of Geoanalysts spatial reproducibility, and the use of He and N2 as carrier gasses during ablation provided enhanced conditions for ablation, as well as superior analytical throughput with respect to Nd-YAG solid state lasers (e.g., Tiepolo 2003, Jackson et al. 2004, Alagna et al. 2008).”
MethodPlešovice zircon — A new natural reference material for U–Pb and Hf isotopic microanalysis
Sláma, J., Košler, J., Condon, D. J., Crowley, J. L., Gerdes, A., Hanchar, J. M., Horstwood, M. S. A., Morris, G. A., Nasdala, L., Norberg, N., et al. (2008) · Chemical Geology · doi:10.1016/j.chemgeo.2007.11.005 · Cited by 5,243 · cited 1×
“Plesovice Plesovice is a relatively new zircon reference material (Sláma et al. 2008), with a calculated concordant age of 337.13 ± 0.37 Ma (2s level).”
BackgroundInfluentialThe Composition of Zircon and Igneous and Metamorphic Petrogenesis
Hoskin, P. W. O. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530027 · Cited by 4,781 · cited 1×
“Since trace element concentrations in zircons can also be used as petrogenetic indicators (Hoskin and Ireland 2000, Pupin 2000, Hoskin and Schaltegger 2003, Belousova et al. 2006, Grimes et al. 2007), this method has capabilities that extend beyond geochronology.”
BackgroundCorrection of common lead in U–Pb analyses that do not report 204Pb
Andersen, T. (2002) · Chemical Geology · doi:10.1016/s0009-2541(02)00195-x · Cited by 4,250 · cited 5×
“Furthermore, our results indicate that even if the 204Pb signal is difficult to detect because of relatively high Hg gas background, a careful evaluation of the 207Pb/206Pb ratio on Tera-Wasserburg diagrams and the use of the correction methods described by Andersen (2002) can provide geologically significant age cons…”
BackgroundMethodInfluentialCorfu, F. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530469 · Cited by 3,659 · cited 1×
“Cathodoluminescence images were important in unravelling the internal zonation of the zircons, thus affording better control over the selection of spots for analysis (e.g., Connelly 2001, Corfu et al. 2003), which in turn helps with the age interpretation.”
BackgroundIgneous zircon: trace element composition as an indicator of source rock type
Belousova, E., Griffin, W., O'Reilly, S. Y., & Fisher, N. (2002) · Contributions to Mineralogy and Petrology · doi:10.1007/s00410-002-0364-7 · Cited by 2,632 · cited 1×
“…or a laser ablation system coupled to an inductively coupled plasma-mass spectrometer with single or multiple ion counting devices (LA-ICP-MS, e.g., Alagna et al. 2008, Belousova et al. 2002, Frei and Gerdes 2009, Gehrels et al. 2008, Horn et al. 2000, Kosler and Sylvester 2003, Tiepolo 2003).”
MethodTEMORA 1: a new zircon standard for Phanerozoic U–Pb geochronology
Black, L. P., Kamo, S. L., Allen, C. M., Aleinikoff, J. N., Davis, D. W., Korsch, R. J., & Foudoulis, C. (2003) · Chemical Geology · doi:10.1016/s0009-2541(03)00165-7 · Cited by 2,311 · cited 4×
“As reported by Black et al. (2004) this is probably the result of crystal inhomogeneities.”
BackgroundResultInfluentialBlack, L. P., Kamo, S. L., Allen, C. M., Davis, D. W., Aleinikoff, J. N., Valley, J. W., Mundil, R., Campbell, I. H., Korsch, R. J., Williams, I. S., et al. (2004) · Chemical Geology · doi:10.1016/j.chemgeo.2004.01.003 · Cited by 1,944 · cited 3×
“Overall, these results seem more accurate than those reported by Black et al. (2004) using LA-ICP-MS (411.9 ± 2.6 Ma), and in the same range as that reported by Bryan et al. (2004), which during three different sessions gave a mean of 419.9 ± 1.4 Ma.”
BackgroundResultInfluentialWilde, S. A., Valley, J. W., Peck, W. H., & Graham, C. M. (2001) · Nature · doi:10.1038/35051550 · Cited by 1,744 · cited 11×
“Earth and Planetary Science Letters, 14, 281-304.”
MethodInfluential
Metadata
- Authors
- Solari, L. A., Gómez‐Tuena, A., Bernal, J. P., Pérez‐Arvizu, O., & Tanner, M.
- Venue
- Geostandards and Geoanalytical Research
- Publisher
- Wiley
- Published
- 2010-03
- Volume
- 34
- Issue
- 1
- Pages
- 5-18
- ISSN
- 0150-5505 (ISSN-L)
- 1639-4488
- 1751-908X
- OpenAlex
- W2075197233
- Cited by
- 236
- References
- 45
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: U‐Pb Zircon Geochronology with an Integrated LA‐ICP‐MS Microanalytical Workstation: Achievements in Precision and Accuracy. https://app.cochat.ai/papers/10.1111/j.1751-908x.2009.00027.x
- The paper
- Solari, L. A., Gómez‐Tuena, A., Bernal, J. P., Pérez‐Arvizu, O., & Tanner, M. (2010). U‐Pb Zircon Geochronology with an Integrated LA‐ICP‐MS Microanalytical Workstation: Achievements in Precision and Accuracy. Geostandards and Geoanalytical Research. https://doi.org/10.1111/j.1751-908x.2009.00027.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.