U‐Pb Zircon Geochronology with an Integrated LA‐ICP‐MS Microanalytical Workstation: Achievements in Precision and Accuracy
The DOI matches its Crossref record; 45 of the 45 references it cites were found in a registry or an index.
Abstract
Laser ablation‐inductively coupled plasma‐mass spectrometry (LA‐ICP‐MS) is a microanalytical tool especially suitable for providing fast and precise U‐Pb geochronological results on zircon grains. A new 193 nm excimer laser adapted to a micromachining workstation, equipped with a newly designed two‐volume ablation cell and coupled with a quadrupole ICP‐MS, is presented here. The system was tuned routinely to achieve sensitivities in the range of 3000 cps/μg g−1 for 238 U (< 2% RSD), with a 34 μm spot size, at 5 Hz and ∼ 8 J cm−2, while ablating the NIST SRM 612 glass reference material. The system was capable of providing fast (< 1.5 minutes each analysis) and precise (generally < 1.5% 1s errors) 206 Pb/238 U zircon ages. The ages of widely used reference material zircons (Plesovice, 337 Ma; Temora, 416 Ma; R33, 418 Ma; Sri Lanka, 564 Ma; 91500, 1065 Ma) could be precisely matched, with an accuracy on isotopic ratios that ranged from ∼ 2 to ∼ 6%, depending on the homogeneity of the natural reference materials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
THREE NATURAL ZIRCON STANDARDS FOR U‐TH‐PB, LU‐HF, TRACE ELEMENT AND REE ANALYSES
WIEDENBECK, M., ALLÉ, P., CORFU, F., GRIFFIN, W. L., MEIER, M., OBERLI, F., QUADT, A. V., RODDICK, J. C., & SPIEGEL, W. (1995) · Geostandards Newsletter · doi:10.1111/j.1751-908x.1995.tb00147.x · Cited by 6,328 · cited 3×
“4 Ma (n=101, 2 sigma, Figure 6A), in good agreement with the ages reported by Wiedenbeck et al. (1995). The average analytical errors at the 2 sigma level for the 207Pb/235U, 206Pb/238U and 207Pb/206Pb isotopic ratios are 4.”
ResultInfluentialJackson, S. E., Pearson, N. J., Griffin, W. L., & Belousova, E. A. (2004) · Chemical Geology · doi:10.1016/j.chemgeo.2004.06.017 · Cited by 5,253 · cited 1×
“…of Geoanalysts spatial reproducibility, and the use of He and N2 as carrier gasses during ablation provided enhanced conditions for ablation, as well as superior analytical throughput with respect to Nd-YAG solid state lasers (e.g., Tiepolo 2003, Jackson et al. 2004, Alagna et al. 2008).”
MethodPlešovice zircon — A new natural reference material for U–Pb and Hf isotopic microanalysis
Sláma, J., Košler, J., Condon, D. J., Crowley, J. L., Gerdes, A., Hanchar, J. M., Horstwood, M. S. A., Morris, G. A., Nasdala, L., Norberg, N., et al. (2008) · Chemical Geology · doi:10.1016/j.chemgeo.2007.11.005 · Cited by 5,243 · cited 1×
“Plesovice Plesovice is a relatively new zircon reference material (Sláma et al. 2008), with a calculated concordant age of 337.13 ± 0.37 Ma (2s level).”
BackgroundInfluentialThe Composition of Zircon and Igneous and Metamorphic Petrogenesis
Hoskin, P. W. O. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530027 · Cited by 4,781 · cited 1×
“Since trace element concentrations in zircons can also be used as petrogenetic indicators (Hoskin and Ireland 2000, Pupin 2000, Hoskin and Schaltegger 2003, Belousova et al. 2006, Grimes et al. 2007), this method has capabilities that extend beyond geochronology.”
BackgroundCorrection of common lead in U–Pb analyses that do not report 204Pb
Andersen, T. (2002) · Chemical Geology · doi:10.1016/s0009-2541(02)00195-x · Cited by 4,250 · cited 5×
“Furthermore, our results indicate that even if the 204Pb signal is difficult to detect because of relatively high Hg gas background, a careful evaluation of the 207Pb/206Pb ratio on Tera-Wasserburg diagrams and the use of the correction methods described by Andersen (2002) can provide geologically significant age cons…”
BackgroundMethodInfluentialCorfu, F. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530469 · Cited by 3,659 · cited 1×
“Cathodoluminescence images were important in unravelling the internal zonation of the zircons, thus affording better control over the selection of spots for analysis (e.g., Connelly 2001, Corfu et al. 2003), which in turn helps with the age interpretation.”
BackgroundIgneous zircon: trace element composition as an indicator of source rock type
Belousova, E., Griffin, W., O'Reilly, S. Y., & Fisher, N. (2002) · Contributions to Mineralogy and Petrology · doi:10.1007/s00410-002-0364-7 · Cited by 2,632 · cited 1×
“…or a laser ablation system coupled to an inductively coupled plasma-mass spectrometer with single or multiple ion counting devices (LA-ICP-MS, e.g., Alagna et al. 2008, Belousova et al. 2002, Frei and Gerdes 2009, Gehrels et al. 2008, Horn et al. 2000, Kosler and Sylvester 2003, Tiepolo 2003).”
MethodTEMORA 1: a new zircon standard for Phanerozoic U–Pb geochronology
Black, L. P., Kamo, S. L., Allen, C. M., Aleinikoff, J. N., Davis, D. W., Korsch, R. J., & Foudoulis, C. (2003) · Chemical Geology · doi:10.1016/s0009-2541(03)00165-7 · Cited by 2,311 · cited 4×
“As reported by Black et al. (2004) this is probably the result of crystal inhomogeneities.”
BackgroundResultInfluentialBlack, L. P., Kamo, S. L., Allen, C. M., Davis, D. W., Aleinikoff, J. N., Valley, J. W., Mundil, R., Campbell, I. H., Korsch, R. J., Williams, I. S., et al. (2004) · Chemical Geology · doi:10.1016/j.chemgeo.2004.01.003 · Cited by 1,944 · cited 3×
“Overall, these results seem more accurate than those reported by Black et al. (2004) using LA-ICP-MS (411.9 ± 2.6 Ma), and in the same range as that reported by Bryan et al. (2004), which during three different sessions gave a mean of 419.9 ± 1.4 Ma.”
BackgroundResultInfluentialWilde, S. A., Valley, J. W., Peck, W. H., & Graham, C. M. (2001) · Nature · doi:10.1038/35051550 · Cited by 1,744 · cited 11×
“Earth and Planetary Science Letters, 14, 281-304.”
MethodInfluentialKrogh, T. E. (1982) · Geochimica et Cosmochimica Acta · doi:10.1016/0016-7037(82)90165-x · Cited by 1,709 · cited 2×
“Krogh T.E. (1982) Improved accuracy of U-Pb zircon ages by the creation of more concordant systems using an air abrasion technique.”
MethodFurther Characterisation of the 91500 Zircon Crystal
Wiedenbeck, M., Hanchar, J. M., Peck, W. H., Sylvester, P., Valley, J., Whitehouse, M., Kronz, A., Morishita, Y., Nasdala, L., Fiebig, J., et al. (2004) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2004.tb01041.x · Cited by 1,519 · cited 1×
“91500 The 91500 zircon is one of the most widely used reference materials for U-Pb dating, although it is no t par t i cu la r l y compos i t iona l l y homogeneous (Wiedenbeck et al. 1995, 2004).”
Mattinson, J. M. (2005) · Chemical Geology · doi:10.1016/j.chemgeo.2005.03.011 · Cited by 1,476 · cited 2×
“The precision can be further improved by applying careful pre-treatment methods, such as mechanical and/or chemical abrasion (Krogh 1982, Mattinson 2005).”
BackgroundMethodGehrels, G. E., Valencia, V., & Ruiz, J. (2008) · Geochemistry Geophysics Geosystems · doi:10.1029/2007gc001805 · Cited by 1,463 · cited 7×
“Both accuracy and precision were readily comparable with those achieved with more complex and expensive systems such as multicollector and/or sector-field ICP-MS and SIMS/SHRIMP systems (e.g., Gehrels et al. 2008, Frei and Gerdes 2009).”
BackgroundMethodInfluentialIsotopes: Principles and Applications
Faure, G., & Mensing, T. M. (2004) · Cited by 1,148
U–Pb dating of monazite and its application to geological problems
Parrish, R. R. (1990) · Canadian Journal of Earth Sciences · doi:10.1139/e90-152 · Cited by 968 · cited 2×
“Several accessory minerals that are commonly found in rocks are suitable for U(Th)-Pb dating: zircon (Mattinson 2005, Parrish and Noble 2003), monazite (Parrish 1990), titanite (Frost et al. 2000) and rutile (Zack et al. 2007).”
BackgroundGrimes, C. B., John, B. E., Kelemen, P. B., Mazdab, F. K., Wooden, J. L., Cheadle, M. J., Hanghøj, K., & Schwartz, J. J. (2007) · Geology · doi:10.1130/g23603a.1 · Cited by 958 · cited 1×
“Since trace element concentrations in zircons can also be used as petrogenetic indicators (Hoskin and Ireland 2000, Pupin 2000, Hoskin and Schaltegger 2003, Belousova et al. 2006, Grimes et al. 2007), this method has capabilities that extend beyond geochronology.”
BackgroundRare earth element chemistry of zircon and its use as a provenance indicator
Hoskin, P. W. O., & Ireland, T. R. (2000) · Geology · doi:10.1130/0091-7613(2000)028<0627:reecoz>2.3.co;2 · Cited by 943
Eggins, S. M., Kinsley, L. P. J., & Shelley, J. M. G. (1998) · Applied Surface Science · doi:10.1016/s0169-4332(97)00643-0 · Cited by 833 · cited 1×
“Depth-related elemental fractionation is a well known phenomenon during laser ablation (e.g., Eggins et al. 1998, Kosler and Sylvester 2003).”
BackgroundBelousova, E. A., Griffin, W. L., & O'Reilly, S. Y. (2005) · Journal of Petrology · doi:10.1093/petrology/egi077 · Cited by 624 · cited 1×
“Since trace element concentrations in zircons can also be used as petrogenetic indicators (Hoskin and Ireland 2000, Pupin 2000, Hoskin and Schaltegger 2003, Belousova et al. 2006, Grimes et al. 2007), this method has capabilities that extend beyond geochronology.”
BackgroundSignal enhancement in laser ablation ICP-MS by addition of nitrogen in the central channel gas
Hu, Z., Gao, S., Liu, Y., Hu, S., Chen, H., & Yuan, H. (2008) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b804760j · Cited by 610 · cited 3×
“As previously reported (e.g., Durrant 1994, Hu et al. 2008), the injection of a small amount of N2 (< 3 ml) has the effect of increasing signal intensity for the whole mass range (Figure 5), thus providing improved statistics on isotope ratios.”
BackgroundSphene (titanite): phase relations and role as a geochronometer
Frost, B. R., Chamberlain, K. R., & Schumacher, J. C. (2001) · Chemical Geology · doi:10.1016/s0009-2541(00)00240-0 · Cited by 549
(1996) · Choice Reviews Online · doi:10.5860/choice.33-3330 · Cited by 509
Horn, I., Rudnick, R. L., & McDonough, W. F. (2000) · Chemical Geology · doi:10.1016/s0009-2541(99)00168-0 · Cited by 496 · cited 1×
“…or a laser ablation system coupled to an inductively coupled plasma-mass spectrometer with single or multiple ion counting devices (LA-ICP-MS, e.g., Alagna et al. 2008, Belousova et al. 2002, Frei and Gerdes 2009, Gehrels et al. 2008, Horn et al. 2000, Kosler and Sylvester 2003, Tiepolo 2003).”
MethodFrei, D., & Gerdes, A. (2008) · Chemical Geology · doi:10.1016/j.chemgeo.2008.07.025 · Cited by 468 · cited 3×
“…the advantage of high sample throughput at a reduced cost; and even if the achievable errors are still ~ 10 times higher than those obtained by ID-TIMS, they are gradually improving as new instruments and analytical strategies are being developed (e.g., Gehrels et al. 2008, Frei and Gerdes 2009).”
BackgroundMethodParagenesis and U-Pb systematics of baddeleyite (ZrO2)
Heaman, L. M., & LeCheminant, A. N. (1993) · Chemical Geology · doi:10.1016/0009-2541(93)90249-i · Cited by 463
Common-Pb corrected in situ U–Pb accessory mineral geochronology by LA-MC-ICP-MS
Horstwood, M., Foster, G. L., Parrish, R. R., Noble, S. R., & Nowell, G. M. (2003) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b304365g · Cited by 461 · cited 1×
“The obse rved uncer ta in t y (% RSD) on the 206Pb/238U, 207Pb/206Pb and 208Pb/232Th ratios of the reference material zircons was quadratically added to the standard error obtained on the measured isotopic ratios of the unknown zircons (e.g., Horstwood et al. 2003).”
BackgroundConsiderations in Zircon Geochronology by SIMS
Ireland, T. R. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530215 · Cited by 457 · cited 2×
“…preparation or pre-treatment and involve the use of either secondary ion mass spectrometry – SIMS (i.e., ion microprobe or SHRIMP instruments, e.g., Ireland and Williams 2003) or a laser ablation system coupled to an inductively coupled plasma-mass spectrometer with single or multiple ion…”
BackgroundMethodMüller, W., Shelley, M., Miller, P., & Broude, S. (2009) · J. Anal. At. Spectrom. · doi:10.1039/b805995k · Cited by 379 · cited 2×
“This was especially useful for ablation at very low repetit ion rates (< 5 Hz, e.g. , Müller et al. 2009).”
BackgroundHanchar, J. M. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530089 · Cited by 370
Present Trends and the Future of Zircon in Geochronology: Laser Ablation ICPMS
Kosler, J. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530243 · Cited by 324 · cited 2×
“…or a laser ablation system coupled to an inductively coupled plasma-mass spectrometer with single or multiple ion counting devices (LA-ICP-MS, e.g., Alagna et al. 2008, Belousova et al. 2002, Frei and Gerdes 2009, Gehrels et al. 2008, Horn et al. 2000, Kosler and Sylvester 2003, Tiepolo 2003).”
BackgroundMethodEggins, S. M., Grün, R., McCulloch, M. T., Pike, A. W. G., Chappell, J., Kinsley, L., Mortimer, G., Shelley, M., Murray-Wallace, C. V., Spötl, C., et al. (2005) · Quaternary Science Reviews · doi:10.1016/j.quascirev.2005.07.006 · Cited by 304 · cited 1×
“This configuration provides high spatial resolution (Eggins et al. 2005; Müller et al., 2009) due to the fast extraction of the ablation plume, with an almost instantaneous signal uptake and a very fast washout of ~ 1-2 s per order of magnitude of signal intensity (Figures 3A, B and C).”
BackgroundHorn, I., & Günther, D. (2003) · Applied Surface Science · doi:10.1016/s0169-4332(02)01324-7 · Cited by 208 · cited 1×
“Before analysis, the cell was purged by a vacuum pump and then filled with He, which provided optimum condition for the laser ablation process (Horn and Günther 2003) and washed the ablated aerosol out of the cell.”
MethodTiepolo, M. (2003) · Chemical Geology · doi:10.1016/s0009-2541(03)00083-4 · Cited by 202 · cited 4×
“Although the effect is minimised with 193 nm ArF excimer lasers when compared to lasers with longer wavelengths of 213 nm (Günther and Hattendorf 2001, Tiepolo 2003), such behaviour is still present and must be taken into account during isotope-ratio calculation.”
BackgroundMethodInfluentialCampbell, I. H., Reiners, P. W., Allen, C. M., Nicolescu, S., & Upadhyay, R. (2005) · Earth and Planetary Science Letters · doi:10.1016/j.epsl.2005.06.043 · Cited by 182 · cited 2×
“A further advantage of laser systems relies on the possibility of dating raw-mounted, unpolished zircons, which can be later used for other studies (Campbell et al. 2005).”
BackgroundUPb ages of zircons: A basic examination of error propagation
Mattinson, J. M. (1987) · Chemical Geology Isotope Geoscience section · doi:10.1016/0168-9622(87)90037-6 · Cited by 149 · cited 1×
“…material zircons, indicated that the 206Pb/204Pb ratio must have been > 10000, and that such a small amount of common Pb did not have a significant effect on the calculated age (i.e., the influence would be less than ± 0.2%, see Mattinson 1987, well within the uncertainty of the measurement).”
BackgroundInfluentialIn situ U-Pb ages of zircons from the Bishop Tuff: No evidence for long crystal residence times
Reid, M. R., & Coath, C. D. (2000) · Geology · doi:10.1130/0091-7613(2000)28<443:isuaoz>2.0.co;2 · Cited by 145
Zircon U-Th-Pb Geochronology by Isotope Dilution -- Thermal Ionization Mass Spectrometry (ID-TIMS)
Parrish, R. R. (2003) · Reviews in Mineralogy and Geochemistry · doi:10.2113/0530183 · Cited by 142 · cited 1×
“Several accessory minerals that are commonly found in rocks are suitable for U(Th)-Pb dating: zircon (Mattinson 2005, Parrish and Noble 2003), monazite (Parrish 1990), titanite (Frost et al. 2000) and rutile (Zack et al. 2007).”
BackgroundLaser-ablation-ICPMS in the earth sciences : principles and applications
Sylvester, P. (2001) · Mineralogical Association of Canada eBooks · Cited by 120
Hirata, T., Iizuka, T., & Orihashi, Y. (2005) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b504153h · Cited by 87
Dickin, A. P., & Muller, R. (1996) · Physics Today · doi:10.1063/1.2807660 · Cited by 69
Bryan, S. E., Allen, C. M., Holcombe, R. J., & Fielding, C. R. (2004) · Australian Journal of Earth Sciences · doi:10.1111/j.1400-0952.2004.01079.x · Cited by 60 · cited 1×
“Overall, these results seem more accurate than those reported by Black et al. (2004) using LA-ICP-MS (411.9 ± 2.6 Ma), and in the same range as that reported by Bryan et al. (2004), which during three different sessions gave a mean of 419.9 ± 1.4 Ma.”
ResultInfluentialBernal, J. P., Eggins, S. M., & McCulloch, M. T. (2005) · Journal of Analytical Atomic Spectrometry · doi:10.1039/b505020k · Cited by 46 · cited 1×
“…ratio from the recommended value of the NIST SRM 612 glass (U/Th = 0.9642) was not attributed to the ablation performance of the cell, as it has been previously demonstrated that U/Th rat ios are highly dependent on ICP variables such as plasma forward power and sampling depth (Bernal et al. 2005).”
Self-citationAlagna, K. E., Petrelli, M., Perugini, D., & Poli, G. (2008) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2008.00866.x · Cited by 36 · cited 3×
“Such dwell times were slightly longer than those used in other work (e.g., Alagna et al. 2008).”
MethodTowards a more accurate U–Pb geochronology
Moser, D. E., & Scott, D. J. (2001) · Chemical Geology · doi:10.1016/s0009-2541(00)00232-1 · Cited by 4
Metadata
- Authors
- Solari, L. A., Gómez‐Tuena, A., Bernal, J. P., Pérez‐Arvizu, O., & Tanner, M.
- Venue
- Geostandards and Geoanalytical Research
- Publisher
- Wiley
- Published
- 2010-03
- Volume
- 34
- Issue
- 1
- Pages
- 5-18
- ISSN
- 0150-5505 (ISSN-L)
- 1639-4488
- 1751-908X
- OpenAlex
- W2075197233
- Cited by
- 236
- References
- 45
- FWCI
- 5.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.