The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Calibration of the New Certified Reference Materials ERM‐AE633 and ERM‐AE647 for Copper and IRMM‐3702 for Zinc Isotope Amount Ratio Determinations
Abstract
The commonly used, but no longer available, reference materials NIST SRM 976 (Cu) and ‘JMC Lyon’ (Zn) were calibrated against the new reference materials ERM®‐AE633, ERM®‐AE647 (Cu) and IRMM‐3702 (Zn), certified for isotope amount ratios. This cross‐calibration of new with old reference materials provides a continuous and reliable comparability of already published with future Cu and Zn isotope data. The Cu isotope amount ratio of NIST SRM 976 yielded δ 65/63 Cu values of −0.01 ± 0.05‰ and −0.21 ± 0.05‰ relative to ERM®‐AE633 and ERM®‐AE647, respectively, and a δ 66/64 Zn IRMM‐3702 value of −0.29 ± 0.05‰ was determined for ‘JMC Lyon’. Furthermore, we separated Cu and Zn from five geological reference materials (BCR‐2, BHVO‐2, BIR‐1, AGV‐1 and G‐2) using a two‐step ion‐exchange chromatographic procedure. Possible isotope fractionation of Cu during chromatographic purification and introduction of resin‐ and/or matrix‐induced interferences were assessed by enriched 65 Cu isotope addition. Instrumental mass bias correction for the isotope ratio determinations by MC‐ICP‐MS was performed using calibrator‐sample bracketing with internal Ni doping for Cu and a double spike approach for Zn. Our results for the five geological reference materials were in very good agreement with literature data, confirming the accuracy and applicability of our analytical protocol.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Natural fractionation of 238U/235U
Weyer, S., Anbar, A. D., Gerdes, A., Gordon, G. W., Algeo, T. J., & Boyle, E. A. (2008) · Geochimica et Cosmochimica Acta · doi:10.1016/j.gca.2007.11.012 · Cited by 509
Siebert, C., Nägler, T. F., & Kramers, J. D. (2001) · Geochemistry Geophysics Geosystems · doi:10.1029/2000gc000124 · Cited by 456
When do black shales tell molybdenum isotope tales?
Gordon, G. W., Lyons, T. W., Arnold, G. L., Roe, J., Sageman, B. B., & Anbar, A. D. (2009) · Geology · doi:10.1130/g25186a.1 · Cited by 132
Cited by
Assessment of international reference materials for isotope-ratio analysis (IUPAC Technical Report)
Brand, W. A., Coplen, T. B., Vogl, J., Rosner, M., & Prohaska, T. (2014) · Pure and Applied Chemistry · doi:10.1515/pac-2013-1023 · Cited by 704
Non-Traditional Stable Isotopes: Retrospective and Prospective
Teng, F.-Z., Dauphas, N., & Watkins, J. M. (2017) · Reviews in Mineralogy and Geochemistry · doi:10.2138/rmg.2017.82.1 · Cited by 272
Sossi, P. A., Halverson, G. P., Nebel, O., & Eggins, S. M. (2015) · Geostandards and Geoanalytical Research · doi:10.1111/j.1751-908x.2014.00298.x · Cited by 262
Metadata
- Authors
- Moeller, K., Schoenberg, R., Pedersen, R., Weiss, D., & Dong, S.
- Venue
- Geostandards and Geoanalytical Research
- Publisher
- Wiley
- Published
- 2012-02
- Volume
- 36
- Issue
- 2
- Pages
- 177-199
- ISSN
- 0150-5505 (ISSN-L)
- 1639-4488
- 1751-908X
- OpenAlex
- W2042229806
- Cited by
- 232
- References
- 3
- FWCI
- 16.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Calibration of the New Certified Reference Materials ERM‐AE633 and ERM‐AE647 for Copper and IRMM‐3702 for Zinc Isotope Amount Ratio Determinations. https://app.cochat.ai/papers/10.1111/j.1751-908x.2011.00153.x
- The paper
- Moeller, K., Schoenberg, R., Pedersen, R., Weiss, D., & Dong, S. (2012). Calibration of the New Certified Reference Materials ERM‐AE633 and ERM‐AE647 for Copper and IRMM‐3702 for Zinc Isotope Amount Ratio Determinations. Geostandards and Geoanalytical Research. https://doi.org/10.1111/j.1751-908x.2011.00153.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.