Doppler Ultrasonographic, Oscillometric Sphygmomanometric, and Photoplethysmographic Techniques for Noninvasive Blood Pressure Measurement in Anesthetized Cats
Abstract
Abstarct: Blood pressure (BP) measurements obtained using 3 indirect BP measuring instruments, a Doppler ultrasonic flowmeter, an oscillometric device, and a photoplethysmograph, were compared with direct arterial pressure measurements in 11 anesthetized cats. The standard deviation of the differences (SOD) between direct and indirect pressure measurements were not significantly different from each other (P<.01), and ranged from 10.82 to 24.32 mm Hg. The high SDD values indicate that indirect BP estimates obtained with all these devices must be interpreted cautiously in individual patients. The mean errors (calculated as the sum of the differences between direct and indirect pressure measurements divided by the number of observations) of the 3 indirect devices were significantly different for systolic (SAP), diastolic (DAP), and mean (MAP) arterial pressures (P<.05). The Doppler and photoplethysmographic devices had the highest overall accuracy, as indicated by mean error values of less than 10 mm Hg. Correlation coefficients varied from .88 to .96 for the Doppler flowmeter, and from .85 to .94 for the photoplethysmograph; for both devices, the regression line slopes were close to unity. The Doppler flowmeter detected a pulse under all experimental conditions. The photoplethysmograph was also efficient in obtaining BP measurements, obtaining over 90% of SAP, DAP, and MAP readings attempted. The oscillometric device was the least accurate, with mean error values varying from 10 to 22 mm Hg. Correlation coefficients were high (.90 to .94) for this device, but the slopes of the regression lines were 0.7 to 0.8, indicating a trend for increased error at higher BP. The oscillometric device tended to underestimate BP by increasing amounts as the BP increased. The oscillometric device was the least efficient device for obtaining BP measurements (P<.01).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Complications of invasive monitoring
Bowdle, T. A. (2002) · Anesthesiology Clinics of North America · doi:10.1016/s0889-8537(02)00004-4 · Cited by 112
Remillard, R. L., Ross, J. N., & Eddy, J. B. (1991) · American Journal of Veterinary Research · doi:10.2460/ajvr.1991.52.04.561 · Cited by 86
Cited by
Brown, S., Atkins, C., Bagley, R., Carr, A., Cowgill, L., Davidson, M., Egner, B., Elliott, J., Henik, R., Labato, M., et al. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb03005.x · Cited by 748
Acierno, M. J., Brown, S., Coleman, A. E., Jepson, R. E., Papich, M., Stepien, R. L., & Syme, H. M. (2018) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.15331 · Cited by 601
Epidemiological study of blood Sressure in omestic dogs
Bodey, A. R., & Michell, A. R. (1996) · Journal of Small Animal Practice · doi:10.1111/j.1748-5827.1996.tb02358.x · Cited by 251
Evaluation of the White-Coat Effect in Cats
Belew, A. M., Barlett, T., & Brown, S. A. (1999) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.1999.tb01141.x · Cited by 225
Indirect measurement of systemic blood pressure in conscious dogs in a clinical setting.
HSIANG, T.-Y., LIEN, Y.-H., & HUANG, H.-P. (2008) · Journal of Veterinary Medical Science · doi:10.1292/jvms.70.449 · Cited by 29
“The limited ability of the transducer to detect systolic pulses might have caused the negative correlation [1].”
BackgroundResult
Metadata
- Authors
- Binns, S. H., Sisson, D. D., Buoscio, D. A., & Schaeffer, D. J.
- Venue
- Journal of Veterinary Internal Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1995-11-01
- Volume
- 9
- Issue
- 6
- Pages
- 405-414
- ISSN
- 0891-6640 (ISSN-L)
- 1939-1676
- OpenAlex
- W2072352225
- Cited by
- 167
- References
- 3
- FWCI
- 4.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Doppler Ultrasonographic, Oscillometric Sphygmomanometric, and Photoplethysmographic Techniques for Noninvasive Blood Pressure Measurement in Anesthetized Cats. https://app.cochat.ai/papers/10.1111/j.1939-1676.1995.tb03301.x
- The paper
- Binns, S. H., Sisson, D. D., Buoscio, D. A., & Schaeffer, D. J. (1995). Doppler Ultrasonographic, Oscillometric Sphygmomanometric, and Photoplethysmographic Techniques for Noninvasive Blood Pressure Measurement in Anesthetized Cats. Journal of Veterinary Internal Medicine. https://doi.org/10.1111/j.1939-1676.1995.tb03301.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.