Interand Intraindividual Variation in Doppler Ultrasonic Indirect Blood Pressure Measurements in Healthy Cats
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Abstarct: This study was undertaken to evaluate reference ranges for systolic blood pressure (SBP) in cats under conditions mimicking a clinical setting. SBP was measured in 50 healthy adult cats of various ages (range, 1.5–16 years) and body weights (range, 2.2–6.1 kg) by Doppler ultrasonic sphygmomanometry. A cuff width of 2.5 cm was used, placed on the left antebrachium, and this represented a mean cuff width of 35% limb circumference (range, 31–42%). The mean (6SD) SBP in the 50 cats was 162 ± 19 mm Hg (range 124–210), with only 1 cat having a SBP ≤ 200 mm Hg. No significant difference (P > .05) in SBP was found between male and female cats, and no significant correlation was found between SBP and age (rs= 0.075) or body weight (rs= 0.007). Further studies in some of these cats indicated that allowing a period of 10 minutes for acclimatization to the environment where SBP was recorded resulted in a significant decrease in SBP from 176 ± 17 to 157 ± 21 mm Hg (n = 7) and that use of a 3.3-cm-width cuff resulted in a significant decrease in measured SBP from 168 ± 13 to 164 ± 13 mm Hg (n = 10). Reproducibility of SBP measurements was evaluated in 7 cats by assessing SBP 7 times at intervals of ≤24 hours over a 10-day period. These 7 cats had a low intraindividual coefficient of variation of SBP measurements (CV ≥ 7.9%) although 2 of the 7 cats had SBP values .200 mm Hg on at least 1 occasion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Remillard, R. L., Ross, J. N., & Eddy, J. B. (1991) · American Journal of Veterinary Research · doi:10.2460/ajvr.1991.52.04.561 · Cited by 86
Cited by
Brown, S., Atkins, C., Bagley, R., Carr, A., Cowgill, L., Davidson, M., Egner, B., Elliott, J., Henik, R., Labato, M., et al. (2007) · Journal of Veterinary Internal Medicine · doi:10.1111/j.1939-1676.2007.tb03005.x · Cited by 748
ISFM Consensus Guidelines on the Diagnosis and Management of Feline Chronic Kidney Disease
Sparkes, A. H., Caney, S., Chalhoub, S., Elliott, J., Finch, N., Gajanayake, I., Langston, C., Lefebvre, H. P., White, J., & Quimby, J. (2016) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x16631234 · Cited by 209
Self-citationEvaluation of the Effects of Hospital Visit Stress on Physiologic Parameters in the Cat
Quimby, J. M., Smith, M. L., & Lunn, K. F. (2011) · Journal of Feline Medicine and Surgery · doi:10.1016/j.jfms.2011.07.003 · Cited by 203
Indirect measurement of systemic blood pressure in conscious dogs in a clinical setting.
HSIANG, T.-Y., LIEN, Y.-H., & HUANG, H.-P. (2008) · Journal of Veterinary Medical Science · doi:10.1292/jvms.70.449 · Cited by 29
“coat effect can be minimized by familiarizing the subjects with the procedure for obtaining the systemic blood pressure value [13, 16].”
Background
Metadata
- Authors
- Sparkes, A. H., Caney, S. M. A., King, M. C. A., & Gruffydd-Jones, T. J.
- Venue
- Journal of Veterinary Internal Medicine
- Publisher
- Oxford University Press (OUP)
- Published
- 1999-07-01
- Volume
- 13
- Issue
- 4
- Pages
- 314-318
- ISSN
- 0891-6640 (ISSN-L)
- 1939-1676
- OpenAlex
- W2026888557
- Cited by
- 97
- References
- 1
- FWCI
- 4.44
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interand Intraindividual Variation in Doppler Ultrasonic Indirect Blood Pressure Measurements in Healthy Cats. https://app.cochat.ai/papers/10.1111/j.1939-1676.1999.tb02187.x
- The paper
- Sparkes, A. H., Caney, S. M. A., King, M. C. A., & Gruffydd-Jones, T. J. (1999). Interand Intraindividual Variation in Doppler Ultrasonic Indirect Blood Pressure Measurements in Healthy Cats. Journal of Veterinary Internal Medicine. https://doi.org/10.1111/j.1939-1676.1999.tb02187.x
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.