Portable lysis apparatus for rapid single-step DNA extraction of Bacillus subtilis
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
AIMS: To demonstrate and characterize a portable lysis apparatus for rapid single-step bacterial DNA extraction. METHODS AND RESULTS: Our portable lysis apparatus employed a novel design consisting of an annular piezo-element with perforated diaphragm. Using Bacillus subtilis as target bacteria, our portable lysis apparatus was able to achieve a normalized percent lysis as high as 66% within 30 s. This is comparable to that by microprobe ultrasonication and almost 7 times higher than that by conventional bead beating. The effect from adding glass beads was predictable. However, the results from the addition of sodium dodecyl sulphate (SDS) were counter-intuitive because a further increase from 0·5 to 1% concentration reduced the lysis performance. The portable lysis apparatus is also at least 1·5-5 times more power efficient than microprobe ultrasonication. CONCLUSIONS: Our portable lysis apparatus is capable of rapidly extracting bacterial DNA and is more power efficient than microprobe ultrasonication. The addition of glass beads or SDS concentration (up to 0·5%) improves its performance. SIGNIFICANCE AND IMPACT OF THE STUDY: The portable lysis apparatus provides a standalone, rapid, low cost and power efficient way of obtaining genomic constituents prior to a variety of bioassays used in the field of environmental, biomedical and other applied microbiology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The complete genome sequence of the gram-positive bacterium Bacillus subtilis.
Kunst, F., Ogasawara, N., Moszer, I., Albertini, A. M., Alloni, G., Azevedo, V., Bertero, M. G., Bessières, P., Bolotin, A., Borchert, S., et al. (1997) · Nature · doi:10.1038/36786 · Cited by 3,679 · cited 1×
“Bacillus subtilis was selected for this study because it is a well-known Gram-positive, aerobic and endospore-forming bacterium (Kunst et al. 1997).”
Waterborne Infectious DiseasesCould They Be Consigned to History?
Fenwick, A. (2006) · Science · doi:10.1126/science.1127184 · Cited by 252 · cited 2×
“Ranging from monitoring of anthropological driven water supplies contamination to timely detection of water borne pathogens such as cholera and typhoid in disaster zones (Gregory and Frick 2000; Craun et al. 2006; Fenwick 2006; Muti et al. 2014; Orata et al. 2014; Pandey et al. 2014), the need for field-compatible and…”
Background
Metadata
- Authors
- Lim, H. J., Lee, E.-H., Yoon, Y., Chua, B., & Son, A.
- Venue
- Journal of Applied Microbiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2016-01-20
- Volume
- 120
- Issue
- 2
- Pages
- 379-387
- ISSN
- 1364-5072 (ISSN-L)
- OpenAlex
- W2178474262
- Cited by
- 219
- References
- 2
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.