The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Association of Atrial Fibrosis Quantified Using LGE‐MRI with Atrial Appendage Thrombus and Spontaneous Contrast on Transesophageal Echocardiography in Patients with Atrial Fibrillation
Open accessAbstract
Atrial Fibrosis and Appendage Thrombus: Introduction: Transesophageal echocardiography (TEE) is used to evaluate for left atrial appendage (LAA) thrombi prior to restoration of sinus rhythm in atrial fibrillation (AF). We examined the relationship of atrial fibrosis quantified using late gadolinium enhancement MRI (LGE‐MRI) with TEE findings. Methods and Results: We included 178 patients with AF, undergoing TEE and LGE‐MRI prior to ablation or cardioversion. LGE‐MRI and subsequent image processing was used to quantify atrial fibrosis based on signal intensity analysis. The mean CHADS 2 score was 1.24 ± 1.08 and CHA 2 DS 2‐VASc was 2.08 ± 1.33. The LAA was classified as normal, spontaneous echocardiographic contrast (SEC) present or thrombus present. LAA thrombus was found in 12 patients (6.7%) while SEC was identified in 19 patients (10.7%). Patients with thrombus had higher atrial fibrosis compared to patients without thrombus (26.9 ± 17.4% vs 16.7 ± 10.5%; P < 0.01). Atrial fibrosis was also higher in patients with SEC (23.3 ± 13.7%) compared to those without SEC (16.7 ± 10.8%; P = 0.01). Patients with high atrial fibrosis (>20%) were more likely to have a LAA thrombus (odds ratio 4.6; P = 0.02) and SEC (odds ratio 2.6; P = 0.06). Multivariate logistic regression showed high fibrosis (odds ratio 3.6; P < 0.01) and CHADS2 ≥2 (odds ratio 3.5; P < 0.01) were significant predictors of TEE abnormalities (LAA thrombus or SEC). The area under the curve for the model including high fibrosis, AF type and CHADS2 ≥2 or CHA 2 DS 2‐VASc ≥2 was 0.73 compared to 0.63 and 0.65 for CHADS2 and CHA 2 DS 2‐VASc alone. Conclusions: Atrial fibrosis is independently associated with appendage thrombus and spontaneous contrast. It provides additional risk stratification not captured by clinical parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Disease and Stroke Statistics—2012 Update: A Report From the American Heart Association
Writing Group Members, Roger, V. L., Go, A. S., Lloyd-Jones, D. M., Benjamin, E. J., Berry, J. D., Borden, W. B., Bravata, D. M., Dai, S., Ford, E. S., et al. (2012) · Circulation · doi:10.1161/cir.0b013e31823ac046 · Cited by 7,333
Wang, T. J., Larson, M. G., Levy, D., Vasan, R. S., Leip, E. P., Wolf, P. A., D’Agostino, R. B., Murabito, J. M., Kannel, W. B., & Benjamin, E. J. (2003) · Circulation · doi:10.1161/01.cir.0000072767.89944.6e · Cited by 1,970
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.12.016 · Cited by 1,456
Cited by
Cardiac Fibrosis in Patients With Atrial Fibrillation
Dzeshka, M. S., Lip, G. Y. H., Snezhitskiy, V., & Shantsila, E. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.06.1313 · Cited by 552
The Left Atrial Appendage: Anatomy, Function, and Noninvasive Evaluation
Beigel, R., Wunderlich, N. C., Ho, S. Y., Arsanjani, R., & Siegel, R. J. (2014) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2014.08.009 · Cited by 516
EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion – an update
Glikson, M., Wolff, R., Hindricks, G., Mandrola, J., Camm, A. J., Lip, G. Y. H., Fauchier, L., Betts, T. R., Lewalter, T., Saw, J., et al. (2020) · EuroIntervention · doi:10.4244/eijy19m08_01 · Cited by 347
Donal, E., Lip, G. Y. H., Galderisi, M., Goette, A., Shah, D., Marwan, M., Lederlin, M., Mondillo, S., Edvardsen, T., Sitges, M., et al. (2016) · European Heart Journal – Cardiovascular Imaging · doi:10.1093/ehjci/jev354 · Cited by 341
EHRA/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion – an update
Glikson, M., Wolff, R., Hindricks, G., Mandrola, J., Camm, A. J., Lip, G. Y. H., Fauchier, L., Betts, T. R., Lewalter, T., Saw, J., et al. (2020) · EP Europace · doi:10.1093/europace/euz258 · Cited by 331
Atrial Failure as a Clinical Entity
Bisbal, F., Baranchuk, A., Braunwald, E., Bayés de Luna, A., & Bayés-Genís, A. (2020) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2019.11.013 · Cited by 283
Atrial fibrillation and cardiac fibrosis
Sohns, C., & Marrouche, N. F. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz786 · Cited by 270
Self-citation
Metadata
- Authors
- Akoum, N., Fernandez, G., Wilson, B., Mcgann, C., Kholmovski, E., & Marrouche, N.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2013-07-11
- Volume
- 24
- Issue
- 10
- Pages
- 1104-1109
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1893471362
- Cited by
- 184
- References
- 3
- FWCI
- 8.05
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.