The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
One‐Year Follow‐Up After Single Procedure Cryoballoon Ablation: A Comparison Between the First and Second Generation Balloon
Abstract
A Comparison Between the First and Second Generation Balloon: Background: With respect to the first generation Cryoballoon (CB), the second generation (Cryoballoon Advance [CB‐A], Medtronic, Minneapolis, MN, USA) was designed with technical modifications resulting in a larger and more uniform zone of freezing on the balloon's surface aiming at procedural outcome improvement in the setting of atrial fibrillation (AF) ablation. However, a comparison between both technologies on a midterm follow‐up is missing in today's literature. Methods: A total of 100 patients (the last 50 patients with the first generation CB and the first 50 patients with the second generation CB‐A upon its inception in our center) having undergone a single CB ablation for paroxysmal AF (PAF) and having completed a 12‐month follow‐up, were consecutively included in our study. Freedom from AF off‐antiarrhythmic drugs (AADs) after a single procedure was 78% (39/50) in CB‐A and 58% (29/50) in the CB group (P = 0.03) during the whole follow‐up duration. Considering a blanking period of 3 months, freedom from AF off‐AAD was achieved in 84% (42/50) in CB‐A, while 66% (33/50) were free from recurrence in the CB group (P = 0.038). Right phrenic nerve palsy (PNP) occurred in 8 patients (16%) in CB‐A group and in 4 patients (8%) in the CB group. Conclusion: Freedom from AF on 12 months follow‐up was significantly higher in the CB‐A group with respect to the first generation device. The most frequent complication observed was PNP.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hindricks, G., Piorkowski, C., Tanner, H., Kobza, R., Gerds-Li, J.-H., Carbucicchio, C., & Kottkamp, H. (2005) · Circulation · doi:10.1161/circulationaha.104.518837 · Cited by 506
Charitos, E. I., Stierle, U., Ziegler, P. D., Baldewig, M., Robinson, D. R., Sievers, H.-H., & Hanke, T. (2012) · Circulation · doi:10.1161/circulationaha.112.098079 · Cited by 196
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Metadata
- Authors
- GIOVANNI, G. D., WAUTERS, K., CHIERCHIA, G., SIEIRA, J., LEVINSTEIN, M., CONTE, G., DE ASMUNDIS, C., BALTOGIANNIS, G., SAITOH, Y., CICONTE, G., JULIA, J., MUGNAI, G., IRFAN, G., & BRUGADA, P.
- Venue
- Journal of Cardiovascular Electrophysiology
- Publisher
- Wiley
- Published
- 2014-04-09
- Volume
- 25
- Issue
- 8
- Pages
- 834-839
- ISSN
- 1045-3873 (ISSN-L)
- 1540-8167
- OpenAlex
- W1926987881
- Cited by
- 167
- References
- 2
- FWCI
- 20.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.