CoChat

Appropriate Implantable Defibrillator Therapy in Adults With Hypertrophic Cardiomyopathy

THAVIKULWAT, AMALIE C., TOMSON, TODD T., KNIGHT, BRADLEY P., BONOW, ROBERT O., CHOUDHURY, LUBNA · 2016 · Journal of Cardiovascular Electrophysiology
Cited by 30

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Appropriate ICD Therapy in HCM: Introduction: Implantable cardioverter‐defibrillators (ICDs) are effective at terminating the ventricular arrhythmias that cause sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM). However, identifying patients at risk for SCD remains an ongoing challenge. Methods and Results: We retrospectively studied all adult patients with HCM treated with ICDs at our referral center from 2000 to 2013 to determine the risk factor profile, rates of appropriate ICD therapy, and complications associated with ICD implantation and discharge. Over a mean follow‐up period of 5.2 ± 4.5 years, ICDs provided appropriate therapy to 25 of 135 patients (2.6%/year for primary prevention, 9.8%/year for secondary prevention). Established risk factors for SCD were equally prevalent among patients who received appropriate therapy and those who did not. There were similar rates of appropriate therapy for primary prevention patients with each risk factor. Patients with multiple risk factors had similar rates of appropriate therapy to patients with a single risk factor. Patients who underwent implantation at a younger age were more likely to experience appropriate therapy. Inappropriate therapy occurred in 27 of 135 patients (20%). Conclusions: These data indicate that the rate of appropriate ICD therapy for primary prevention in a contemporary adult HCM population is lower than previously reported. The frequency of appropriate therapy was equally modest regardless of the nature and number of risk factors that led to ICD implantation, and patients with multiple risk factors for SCD did not have an increased rate of appropriate therapy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1111/jce.13005

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 30

Metadata

Authors
THAVIKULWAT, A. C., TOMSON, T. T., KNIGHT, B. P., BONOW, R. O., & CHOUDHURY, L.
Venue
Journal of Cardiovascular Electrophysiology
Publisher
Wiley
Published
2016-06
Volume
27
Issue
8
Pages
953-960
ISSN
  • 1045-3873 (ISSN-L)
  • 1540-8167
OpenAlex
W2346101269
Cited by
30
References
4
FWCI
4.48
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Appropriate Implantable Defibrillator Therapy in Adults With Hypertrophic Cardiomyopathy. https://app.cochat.ai/papers/10.1111/jce.13005
The paper
THAVIKULWAT, A. C., TOMSON, T. T., KNIGHT, B. P., BONOW, R. O., & CHOUDHURY, L. (2016). Appropriate Implantable Defibrillator Therapy in Adults With Hypertrophic Cardiomyopathy. Journal of Cardiovascular Electrophysiology. https://doi.org/10.1111/jce.13005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.